Background: This study aimed to compare the therapeutic outcomes and fatal carotid blow out syndrome (CBOS) incidence rates between two different stereotactic body radiotherapy (SBRT) protocols. Methods: The study included 75 patients with inoperable locally recurrent head and neck cancer treated with SBRT in our department between June 2007 and March 2011. The first 43 patients were treated sequentially (group I). Then our SBRT protocol was changed due to the high rate of CBOS, and the following 32 patients were treated every other day in a prospective institutional protocol (group II). Results: Median overall survival in group I and group II was 11 months and 23 months, respectively (P = 0.006). We observed 11 cases of CBOS. Only 1 of 7 patients (14%) with CBOS survived in group I, whereas 2 of 4 patients (50%) in group II remain alive. CBOS free median overall survivals were 9 months, and 23 months in group I and group II respectively (P = 0.002). The median radiation dose received by the carotid artery in patients with CBOS was 36.5 Gy (range: 34–42.8 Gy), versus 34.7 Gy (range: 0–44 Gy) in the patients that didn’t have CBOS (P = 0.15). CBOS did not occur in any of the patients with a maximum carotid artery radiation dose <34 Gy. Conclusions: Every other day SBRT protocol for re-irradiation of recurrent head and neck cancer is promising in terms of decreasing the incidence of fatal CBOS.
Aim: The aim of this study was to investigate the adequacy of nanoDot optically stimulated luminescence (OSL) dosimeter for small field dosimetry before its in vivo applications in CyberKnife SRS unit. Materials and Methods: A PTW 60018 SRS Diode, 60019 microDiamond, and Gafchromic EBT3 films were used along with a nanoDot carbon-doped aluminum oxide OSL dosimeter to collect and compare beam data. In addition, the EGSnrc/BEAMnrc code was employed to simulate 6-MV photon beams of CyberKnife SRS system. Results: All detectors showed good consistency with each other in output factor measurements for cone sizes of 15 mm or more. The differences were maintained within 3% for these cones. However, OSL output factors showed higher discrepancies compared to those of other detectors for smaller cones wherein the difference reached nearly 40% for cone size of 5 mm. Depending on the performance of OSL dosimeter in terms of output factors, percentage depth doses (PDDs) were only measured for cones equal to or larger than 15 mm. The differences in PDD measurements were within 5% for depths in the range of 5–200 mm. Conclusion: Its low reliable readings for cones smaller than 15 mm should be considered before its in vivo applications of Cyberknife system.
1 January 2020 in Reports of Practical Oncology and Radiotherapy
Aim: The aim of this study was to determine the Inflection Points (IPs) of flattening filter free (FFF) CyberKnife dose profiles for cone-based streotactic radiotherapy. In addition, dosimetric field sizes were determined. Background: The increased need for treatment in the early stages of cancer necessitated the treatment of smaller tumors. However, efforts in that direction required the modeling accuracy of the beam. Removal of the flattening filter (FF) from the path of x-ray beam has provided the solution to those efforts, but required a different normalization approach for the beam to ensure the delivery of the dose accurately. As a solution, researchers proposed a normalization factor based on IPs. Materials and methods: Measurements using microDiamond (PTW 60019), Diode SRS (PTW 60018) and Monte Carlo (MC) calculations of dose profiles were completed at SAD 80 cm and 5 cm depth for 15-60 mm cones. Performance analysis of detectors with respect to MC calculation was carried out. Gamma evaluation method was used to determine achievable acceptability criteria for FFF CyberKnife beams. Results: Acceptability within (3%-0.5 mm) was found to be anachievable criterion for all dose profile measurements of the cone beams used in this study. To determine the IP, the first and second derivatives of the dose profile were determined via the cubic spline interpolation technique. Conclusion: Derivatives of the interpolated profiles showed that locations of IPs and 50% isodose points coincide. (C) 2019 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.