Kristian Dahl Hertz

Kristian Dahl Hertz

Auto-generated profile, based on publicly available information

Kristian Dahl Hertz

Civil Engineering Department, Technical University of Denmark, Kongens Lyngby, Denmark

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 January 2017 in Engineering Structures
Verified
Journal Article
Closed access
PHPhilip Skov Halding
Philip Skov Halding
KHKristian D. Hertz
Kristian D. Hertz
JSJacob Wittrup Schmidt
Jacob Wittrup Schmidt
BKBryan J. Kennedy
Bryan J. Kennedy

1 October 2009 in Magazine of Concrete Research
Verified
Journal Article
Open access
KHK.D. Hertz
K.D. Hertz
The paper presents a new technology invented by the author by means of which it is possible to create very light concrete structures. The new super-light structures are resource-saving in terms of consumption of raw materials and energy for production and transport, and the cost is often less than half that of similar structures in concrete and steel. They are heat-insulating, fire-resistant and they open up the possibility for large spans and the creation of advanced shapes. Fields of application include roofs, shells, beams, columns, walls, façades, offshore structures, tunnels and structures with large spans for bridges, factories, warehouses, shopping centres, car parks, assembly and sports halls and so on. The new structures are new applications for well-understood components, so it is not necessary to prove that they are possible. However, the paper presents tests that were made to illustrate the applicability and to reveal any potential hidden problems. Continuing research will aim to reduce the weight and thereby the resource consumption further. In addition, the paper introduces pearl-chain reinforcement, which is a new principle for creating compression and tension zones. A small number of simple mass-produced prefabricated components are used to establish compression and tension zones for optimised or advanced shapes in super-light structures. Furthermore, the principle provides new options for prestressing light aggregate concrete structures in general. Pearl-chain reinforcement is self-supporting. It is visible and open for inspection before being cast into a structure, and it can support moulds for the structure, reducing the need for scaffolding. Stable meshes of pearl-chain reinforcement are advantageous for both large-scale structures, such as bridges, girders, shells and domes, and for small-scale applications, such as façade elements, crash barriers and secondary structures. One special small-scale application of the principle is in frame building, where super-light frames with pearl-chain-reinforced components have some of the same advantages as timber-frame structures with regard to stability, heat insulation, economy and simple erection processes, but without the disadvantages of fire and rot.

6 September 2021 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
KHKristian Dahl Hertz
Kristian Dahl Hertz
LSLars Schiøtt Sørensen
Lars Schiøtt Sørensen
LGLuisa Giuliani
Luisa Giuliani
Purpose: This study aims to analyze and discuss the key design assumptions needed for design of car parks in steel, to highlight the impact that the increased fire loads introduced by modern cars and changes in the fire dynamics have on the design, such as fire spread leading to non-localized fires.Design/methodology/approach: In particular, a reliable fire load density to be used for structural design of car park structures is assessed, based on investigations of the fire loads of modern cars. Based on knowledge of fire load and fire performance of cars, the consequences on the fire safety design of steel structures are presented.Findings: Design recommendation about fire load density and fire protection of common steel profiles are given. Finally, the proposed design is compared with a design practice that has been applied in many instances for car parks constructed with unprotected steel, and recommendations for a reliable design process are provided.Originality/value: Numerous car park buildings have recently been designed of steel structures without passive or active fire protection. The key assumptions that makes possible such design are local fire scenarios, outdated values of the car fire load and utilization of the ultimate steel strength. This paper identifies the shortcomings of such key assumptions, indicating the need for revisiting the methods and possibly even checking the analyses carried out for some already-built car parks.

1 January 2019
Verified
Book Chapter
Open access
KHKristian Dahl Hertz
Kristian Dahl Hertz