Alberto B. Diez

Alberto B. Diez

Auto-generated profile, based on publicly available information

Alberto B. Diez

Electrical Engineering, University of Oviedo, Spain

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2009 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
GDGuzmán Diaz
Guzmán Diaz
Cristina González-MoránCristina González-Morán
Cristina González-Morán
JGJavier Gomez-Aleixandre
Javier Gomez-Aleixandre
ADAlberto Diez
Alberto Diez
This paper details a procedure based on bifurcation theory to evaluate the impact that droops and primary reserve scheduling have on the microgrid stability. The methodology is based on finding the worst primary reserve share-that is, the share closest to instability-that can be found after rescheduling the droops of selected generating units that support frequency (and voltage) regulation. The solution-which consists of a measure of the distance to instability in a given direction-is found in a multi-parameter space endowed with coordinates corresponding to the droop coefficients. Two stages are proposed to achieve the solution. First, an investigation of the distance to bifurcation is computed in a one-dimensional parameter space in a defined search direction. Then the direction of this search is updated by calculating the normal vector at the found bifurcation point. The procedure is iteratively repeated until the closest bifurcation is found. The proposed approach is analyzed in a 69-bus and 11-generation unit isolated microgrid. It is shown through the analysis of some scenarios how the distances and normal vectors provide valuable insight on the correct scheduling from the stability point of view, giving advice on how the primary reserve should be more reliably scheduled.

2 December 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
FBFernando Briz
Fernando Briz
MDMichael W. Degner
Michael W. Degner
PFPablo García Fernández
Pablo García Fernández
ADAlberto B. Diez
Alberto B. Diez
The diagnosis of stator winding faults in inverter-fed AC machines using an injected high-frequency carrier-signal voltage is analyzed in this paper. Measurement of the resulting carrier signals (either the negative-sequence carrier-signal current or the zero-sequence components) is used to detect turn faults at an incipient stage. The carrier frequency and magnitude are shown to have significant impact on the performance of the method, with the criteria for their selection being presented. The proposed technique shows low sensitivity to the working condition of the machine, i.e., torque level, flux levels, and fundamental excitation frequency.

25 January 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
DRDavid Díaz Reigosa
David Díaz Reigosa
DADaniel Fernández Alonso
Daniel Fernández Alonso
MMMartinez Maria
Martinez Maria
JMJuan Manuel Guerrero Muñoz
Juan Manuel Guerrero Muñoz
ADAlberto B. Diez
Alberto B. Diez
FBFernando Briz
Fernando Briz
Permanent magnet synchronous machines (PMSMs) torque production capability depends on the permanent magnets (PMs) magnetization state, which can be affected by PMs temperature and of the current flowing throughout the stator windings; knowledge of the PMs temperature can be therefore of great importance both for control and monitoring purposes. PMs temperature can be measured or estimated; PM temperature measurement is not easy and is not normally implemented in commercial drives. PM temperature estimation methods can be divided into thermal models based, BEMF based and signal injection based methods. Existing HF signal injection methods estimate the PM temperature from the measured stator HF resistance. Unfortunately the resistance is also affected by magnetoresistive effect, which can limit the accuracy of the estimates. This paper proposes the use of the stator d-axis HF inductance for PM temperature estimation. This makes temperature estimation insensitive to magnetoresistive effect. In addition, it allows the use of higher frequencies, reducing the adverse impact of the injected signal on machine performance.

25 September 2009 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
GDGuzmán Diaz
Guzmán Diaz
Cristina González-MoránCristina González-Morán
Cristina González-Morán
JGJavier Gomez-Aleixandre
Javier Gomez-Aleixandre
ADAlberto Diez
Alberto Diez
This paper focuses on representing the state space model of a microgrid in which power regulated (PQ ) and voltage/frequency regulated (Vf) generation units share a distribution system. The generation units considered in this paper are inverter interfaced. This introduces some interesting modeling problems which are treated in the paper, such as the decoupled cascaded control schemes or the non-negligible grid dynamics. A modeling approach is proposed based on four defined complex vectors. These vectors allow for complex-valued system matrices to be formed in a quite automated way. Moreover, a convenient partition of the system matrices is proposed, which in turn allows fast and easy modifications. Additionally, a multivariable methodology is proposed to simultaneously find the control system gains in an optimal sense. A 69-bus radial system, supplied by 20 generation units, is used to demonstrate how the proposal is of easy implementation to conduct small-signal stability analyses.

16 May 2008 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
FBFernando Briz
Fernando Briz
MDMichael W. Degner
Michael W. Degner
JMJuan Manuel Guerrero Muñoz
Juan Manuel Guerrero Muñoz
ADAlberto B. Diez
Alberto B. Diez
Temperature monitoring using the injection of a high-frequency carrier signal voltage is proposed in this paper. The carrier signal voltage is used to estimate the transient impedance of the system, which is a function of the stator transient resistance and, therefore, the windingspsila temperature. The variation of the stator transient impedancepsilas phase angle is used to track the temperature of the stator windings. The method can be implemented in standard inverter-fed drives with no additional hardware, with minimal computational requirements, and with practically no interference with the regular operation of the drive.

27 February 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
DRDavid Díaz Reigosa
David Díaz Reigosa
DADaniel Fernández Alonso
Daniel Fernández Alonso
YPYonghyun Park
Yonghyun Park
ADAlberto B. Diez
Alberto B. Diez
SLSang Bin Lee
Sang Bin Lee
DDDavid Diaz
David Diaz
Torque production capability of permanent magnet synchronous machines (PMSMs) depends on the magnetization state of the permanent magnets (PMs). Electrical stress, thermal stress, or the combined effect of both can produce demagnetization of the PMs, which eventually can result in several adverse effects including decrease in the motor torque and efficiency, and increase of the torque ripple and vibration, eventually degrading the performance and reliability of the motor and drive system. A number of approaches have been proposed for detecting PM demagnetization using model-based flux estimation, signal injection, spectrum analysis of current/back-EMF; however, all these methods show limitations in terms of invasiveness, implementation cost and/or reliability of the diagnosis. In this paper, accurate PM demagnetization detection based on measurements from hall-effect sensors is proposed. Such sensors are often mounted in commercial PMSMs, the proposed method can therefore be implemented at practically no cost.