Piotr R. Slawinski

Piotr R. Slawinski

Auto-generated profile, based on publicly available information

Piotr R. Slawinski

Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
JNJoseph C. Norton
Joseph C. Norton
PSPiotr R. Slawinski
Piotr R. Slawinski
HLHolly Lay
Holly Lay
JMJames W. Martin
James W. Martin
BCBenjamin F. Cox
Benjamin F. Cox
PVPietro Valdastri
Pietro Valdastri
A capsule robot uses magnetic control and microultrasound feedback for in situ autonomous positioning and diagnostics of microanatomy.

11 June 2019 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
PSPiotr R. Slawinski
Piotr R. Slawinski
NSNabil Simaan
Nabil Simaan
ATAddisu Z. Taddese
Addisu Z. Taddese
KOKeith L. Obstein
Keith L. Obstein
PVPietro Valdastri
Pietro Valdastri
The navigation of magnetic medical robots typically relies on localizing an actuated, intracorporeal, ferromagnetic body and back-computing a necessary field and gradient that would result in a desired wrench on the device. Uncertainty in this localization degrades the precision of force transmission. Reducing applied force uncertainty may enhance tasks such as in vivo navigation of miniature robots, actuation of magnetically guided catheters, tissue palpation, as well as simply ensuring a bound on forces applied on sensitive tissue. In this paper, we analyze the effects of localization noise on force uncertainty by using sensitivity ellipsoids of the magnetic force Jacobian and introduce an algorithm for uncertainty reduction. We validate the algorithm in both a simulation study and in a physical experiment. In simulation, we observe reductions in estimated force uncertainty by factors of up to 2.8 and 3.1 when using one and two actuating magnets, respectively. On a physical platform, we demonstrate a force uncertainty reduction by a factor of up to 2.5 as measured using an external sensor. Being the first consideration of force uncertainty resulting from noisy localization, this paper provides a strategy for investigators to minimize uncertainty in magnetic force transmission.

4 July 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
PSPiotr R. Slawinski
Piotr R. Slawinski
NSNabil Simaan
Nabil Simaan
KOKeith L. Obstein
Keith L. Obstein
PVPietro Valdastri
Pietro Valdastri
Traditional endoscopes consist of a flexible body and a steerable tip with therapeutic capability. Although prior endoscopes have relied on operator pushing for actuation, recent robotic concepts have relied on the application of a tip force for guidance. In such case, the body of the endoscope can be passive and compliant; however, the body can have significant effect on mechanics of motion and may require modeling. As the endoscope body's shape is often unknown, we have developed an estimation method to recover the approximate distal shape, local to the endoscope's tip, where the tip position and orientation are the only sensed parameters in the system. We leverage a planar dynamic model and extended Kalman filter to obtain a constant-curvature shape estimate of a magnetically guided endoscope. We validated this estimator in both dynamic simulations and on a physical platform. We then used this estimate in a feed-forward control scheme and demonstrated improved trajectory following. This methodology can enable the use of inverse-dynamic control for the tip-based actuation of an endoscope, without the need for shape sensing.