Holly Lay

Dr. Holly Lay

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
JNJoseph C. Norton
Joseph C. Norton
PSPiotr R. Slawinski
Piotr R. Slawinski
HLHolly Lay
Holly Lay
JMJames W. Martin
James W. Martin
BCBenjamin F. Cox
Benjamin F. Cox
PVPietro Valdastri
Pietro Valdastri
A capsule robot uses magnetic control and microultrasound feedback for in situ autonomous positioning and diagnostics of microanatomy.

3 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
JFJulia Faerber
Julia Faerber
RGRachael Gregson
Rachael Gregson
RCRichard Clutton
Richard Clutton
Sadeque Reza KhanSadeque Reza Khan
Sadeque Reza Khan
SCSandy Cochran
Sandy Cochran
CCCiaran Connor
Ciaran Connor
This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a $\text{10\,mm\,}\times \,\text{30\,mm}$ capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of –10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10−3 packet error rate and 10−5 bit error rate and no temperature increase of the tissue according to IEEE standards.

2 July 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CCChristopher Cheng
Christopher Cheng
ADAjay Dangi
Ajay Dangi
LRLiqiang Ren
Liqiang Ren
STSudhanshu Tiwari
Sudhanshu Tiwari
RBRobert R. Benoit
Robert R. Benoit
STSusan Trolier-McKinstry
Susan Trolier-McKinstry
Lead zirconate titanate (PZT) based piezoelectric micromachined ultrasonic transducers (PMUTs) for particle manipulation applications were designed, fabricated, characterized and tested. The PMUTs had a diaphragm diameter of 60 lm, a resonant frequency of ∼ 8 MHz and an operational bandwidth of 62.5%. Acoustic pressure output in water was 9.5 kPa at 7.5 mm distance from a PMUT element excited with a unipolar waveform at 5 Vpp. The element consisted of 20 diaphragms connected electrically in parallel. Particle trapping of 4 lm silica beads was shown to be possible with 5 Vpp unipolar excitation. Trapping of multiple beads by a single element and deterministic control of particles via acoustophoresis without the assistance of microfluidic flow were demonstrated. It was found that the particles move towards diaphragm areas of highest pressure, in agreement with literature and simulations. Unique bead patterns were generated at different driving frequencies and were formed at frequencies up to 60 MHz, much higher than the operational bandwidth. Levitation planes were generated above 30 MHz driving frequency.

1 March 2020 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
YQYongqiang Qiu
Yongqiang Qiu
YHYaocai Huang
Yaocai Huang
ZZZhiqiang Zhang
Zhiqiang Zhang
BCBenjamin F. Cox
Benjamin F. Cox
Rong LiuRong Liu
Rong Liu
SCSandy Cochran
Sandy Cochran
Wireless capsule endoscopy has been used for the clinical examination of the gastrointestinal (GI) tract for two decades. However, most commercially available devices only utilise optical imaging to examine the GI wall surface. Using this sensing modality, pathology within the GI wall cannot be detected. Micro-ultrasound (μUS) using high-frequency (>20 MHz) ultrasound can provide a means of transmural or cross-sectional image of the GI tract. Depth of imaging is approximately 10 mm with a resolution of between 40-120 μm that is sufficient to differentiate between subsurface histologic layers of the various regions of the GI tract. Ultrasound capsule endoscopy (USCE) uses a capsule equipped with μUS transducers that are capable of imaging below the GI wall surface, offering thereby a complementary sensing technique to optical imaging capsule endoscopy. In this work, a USCE device integrated with a ∼30 MHz ultrasonic transducer was developed to capture a full 360° image of the lumen. The performance of the device was initially evaluated using a wire phantom, indicating an axial resolution of 69.0 μm and lateral resolution of 262.5 μm. Later, in vivo imaging performance was characterised in the oesophagus and small intestine of anaesthetized pigs. The reconstructed images demonstrate clear layer differentiation of the lumen wall. The tissue thicknesses measured from the B-scan images show good agreement with ex vivo images from the literature. The high-resolution ultrasound images in the in vivo porcine model achieved with this device is an encouraging preliminary step in the translation of these devices toward future clinical use.

5 July 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
HLHolly Lay
Holly Lay
MDMarc Desmulliez
Marc Desmulliez
SCSandy Cochran
Sandy Cochran
Gerard CumminsGerard Cummins
Gerard Cummins
BCBenjamin F. Cox
Benjamin F. Cox
RCRichard Clutton
Richard Clutton
Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a non-invasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (μUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of μUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of μUS B-scans and safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and μUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature μUS systems.

1 May 2017 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
BCBenjamin F. Cox
Benjamin F. Cox
FSFraser Stewart
Fraser Stewart
HLHolly Lay
Holly Lay
Gerard CumminsGerard Cummins
Gerard Cummins
INIan P. Newton
Ian P. Newton
SCSandy Cochran
Sandy Cochran
Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently.