Nicolas Kruse

Nicolas Kruse

Auto-generated profile, based on publicly available information

Nicolas Kruse

Forschungszentrum Jülich GmbH, Institute of Energy Technologies, Fundamental Electrochemistry, IET-1, Wilhelm-Johnen-Straße, 52428 Jülich, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
RPRo. Peters
Ro. Peters
WTW. Tiedemann
W. Tiedemann
IHI. Hoven
I. Hoven
RDR. Deja
R. Deja
NKN. Kruse
N. Kruse
RER.-A. Eichel
R.-A. Eichel
In 2018, a 5/15 kWDCreversible solid oxide cell system was developed and successfully operated by Forschungszentrum Jülich. Based on the knowledge gained with this first system, an optimized system in the power class of 10/40 kWACwas developed afterwards in 2019 that uses the well-established Integrated Module. This module consists of four 20-layer sub-stacks, two heat exchangers and five heating plates. It represents the main components of the system. The basic system layout was retained in general from the previous system and adjusted in accordance with the higher power level, as well as the supporting balance of plant components. The layout of the demonstrator system and its results are described. During the experimental evaluation in fuel cell mode, the system could provide an electrical output power from 1.7 to 13 kWAC. The maximum system efficiency of 63.3% based on the lower heating value (LHV) could be reached at a system power of 10.4 kWAC. This operating point was also analyzed regarding the temperature distribution in the stack and efficiency losses. In electrolysis mode, a maximum efficiency of 71.1% (LHV) was achieved with an electrical power input of −49.6 kWAC. At this operating point, about 11.7 Nm3h−1of hydrogen are generated. The stack temperature distribution and the efficiency losses are also analyzed for the electrolysis mode. Finally, the potential for the efficiency optimization through higher heat integration in this mode is experimentally evaluated and discussed.

1 May 2016 in Separation and Purification Technology
Verified
Journal Article
Closed access
NKN. Kruse
N. Kruse
YSY. Schießer
Y. Schießer
SKS. Kämnitz
S. Kämnitz
Hannes RichterHannes Richter
Hannes Richter
IVI. Voigt
I. Voigt
JRJ.U. Repke
J.U. Repke

8 January 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
KZK. Zimmer
K. Zimmer
WHW. Hater
W. Hater
AIA. Icart
A. Icart
JJJ. Jaworski
J. Jaworski
NKN. Kruse
N. Kruse
Gerd BraunGerd Braun
Gerd Braun
A new membrane-based method was applied to investigate the performance of three phosphorus-free antiscalants of different chemical structures to prevent calcium carbonate scale. Apart from a polyacrylate homopolymer, two copolymers were studied, one of it also being free of nitrogen. The results show that an inhibition of CaCO3 scale on reverse osmosis (RO) membranes is possible with phosphorus-free antiscalants. The individual performance strongly depends on the chemical structure of the polycarboxylate. A specially adapted copolymer clearly outperforms the polyacrylate homopolymer in case of severe scaling conditions. The average residence time of the water in the test plant is approximately 1 h, compared to around less than a minute in a full-scale RO plant. So the operating conditions in the test plant make it more difficult for an AS to inhibit scaling compared to a full-scale RO plant. By energy-dispersive X-ray fluorescence (EDXRF), the scaling layer thickness can be estimated. The SEM images and the 3D images from CLSM showed that the water quality and the applied antiscalant have a great influence on the scaling layer morphology. The effective blocking of the membrane does not only depend on the amount of precipitated CaCO3 but there is also a great influence of the scaling layer structure. With a normal scaling potential of the water, the scaling layer consists of calcite, and at higher LSI values of the feed water, there was also aragonite found on the membrane. From the three antiscalants AA/AMPS shows, as it was expected, the lowest performance as calcium carbonate scale inhibitor, because it is designed predominantly as a disperser and as stabilizer for calcium phosphate. PAA proved to be an efficient inhibitor for hardness at standard applications. For the application in waters with high scaling potential, AA/EA is very suitable, because this inhibitor is able to serve as a good stabilizer for hardness and at the same time as a disperser. A combination of different polymers enables special solutions for high requirements.

1 November 2022 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
SZShidong Zhang
Shidong Zhang
RPRoland Peters
Roland Peters
BVBob Varghese
Bob Varghese
RDRobert Deja
Robert Deja
NKNicolas Kruse
Nicolas Kruse
RERüdiger-A. Eichel
Rüdiger-A. Eichel
This work describes a recently-developed numerical model for three-dimensional, steady-state simulations of reversible solid oxide cell (rSOC) stacks, taking into account a heterogeneous temperature field. The model employs a volume-averaged approach, also referred to as the distributed resistance analogy. It considers fluid flow, multi-component species diffusion, as well as heat and mass transfer, including thermal radiation and electrochemical reactions. The implementation of the computational model is based on an open-source library, OpenFOAM. An in-house designed rSOC stack, Mark-H is considered. Simulations are performed for repeating units with a 320 cm2 active area, with both the present stack model and a one-dimensional Simulink model. Both models predict very similar voltages, with a maximum difference of 2% compared to experimental results. The present model shows a temperature distribution closer to the experimental data than the Simulink model, although a slightly longer simulation time is required.

25 February 2025 in Sustainable Energy & Fuels
Verified
Journal Article
Open access
PDF file
VSVictor Selmert
Victor Selmert
LPLeandros Paschalidis
Leandros Paschalidis
NKNicolas Kruse
Nicolas Kruse
SDSteffen Dirkes
Steffen Dirkes
AKAnsgar Kretzschmar
Ansgar Kretzschmar
Rüdiger-A. EichelRüdiger-A. Eichel
Rüdiger-A. Eichel
The application of Direct Air Capture (DAC) for extracting CO2 from the atmosphere has a great potential to reduce net CO2 emissions and help achieve climate goals. Besides storing the separated CO2, it can be used as a carbon feedstock for producing CO2-neutral e-fuels, marking a critical research focus area. Despite advancements in various DAC technologies and processes, their large-scale implementation remains limited, among other reasons, because of the large amounts of energy required to power such processes. This article explores the utilization of DAC for water-conscious production of methanol in sunny regions, using cost-efficient photovoltaic power. The selected approach is presented, which involves a process on demonstrator scale with amine-based DAC for CO2 and water separation from air, high-temperature electrolysis using solid oxide electrolysis cells (SOEC) for syngas production, and subsequent methanol synthesis. We also discuss alternative methods, potential locations, and implementation strategies, highlighting the advantages but also the challenges of producing green methanol in sunny regions outside Germany.

1 December 2017 in Journal of Membrane Science
Verified
Journal Article
Closed access
NKNicolas Kruse
Nicolas Kruse
YSYuliya Schießer
Yuliya Schießer
NRNorman Reger-Wagner
Norman Reger-Wagner
HRHannes Richter
Hannes Richter
IVIngolf Voigt
Ingolf Voigt
JRJens-Uwe Repke
Jens-Uwe Repke