Solid oxide cells are capable of efficiently converting various chemical energy carriers to electricity and vice versa. The urgent challenge nowadays is the faster degradation rate compared with other fuel cell/electrolyzer technologies. To understand the degradation mechanisms, simulation of a solid oxide cell is helpful. Since most previous research developed models using commercial software, such as COMSOL and ANSYS Fluent, a gap for knowledge transfer is being gradually formed between academia and industry due to licensing issues. This paper introduces a multiphysics model, developed by a computational code, openFuelCell2. The code is implemented with an open-source library, OpenFOAM. It accounts for momentum transfer, mass transfer, electrochemical reactions and metal interconnect oxidation. The model can precisely predict I–V curves under different temperatures, fuel humidity and operation modes. Comparison between OpenFOAM and COMSOL simulations shows good agreement. The metal interconnect oxidation is modeled, which can predict the thickness of the oxide scale under different protective coatings. Simulations are conducted by assuming an ultra-thin film resistance on the rib surface. It is revealed that coatings fabricated by atmospheric plasma spraying can efficiently prevent metal interconnect oxidation, with a contribution of only 0.53 % to the total degradation rate.
1 November 2022 in Journal of the Electrochemical Society
This work describes a recently-developed numerical model for three-dimensional, steady-state simulations of reversible solid oxide cell (rSOC) stacks, taking into account a heterogeneous temperature field. The model employs a volume-averaged approach, also referred to as the distributed resistance analogy. It considers fluid flow, multi-component species diffusion, as well as heat and mass transfer, including thermal radiation and electrochemical reactions. The implementation of the computational model is based on an open-source library, OpenFOAM. An in-house designed rSOC stack, Mark-H is considered. Simulations are performed for repeating units with a 320 cm2 active area, with both the present stack model and a one-dimensional Simulink model. Both models predict very similar voltages, with a maximum difference of 2% compared to experimental results. The present model shows a temperature distribution closer to the experimental data than the Simulink model, although a slightly longer simulation time is required.
Chromium poisoning strongly influences the performance of solid oxide fuel cell (SOFC) stacks. A novel numerical model is introduced by incorporating the chemical and electrochemical aspects of chromium poisoning. It offers a detailed analysis of the spatial distribution of critical chromium-based species, including SrCrO4 and Cr2O3. This model is integrated with a pre-existing three-dimensional, time-dependent computational fluid dynamics (CFD) toolbox, openFuelCell2. The numerical simulations indicate a quantitative agreement with experimental data over an extended 100 kh operation. Numerical simulations are conducted within a representative channel geometry originating from an F10 SOFC stack at Forschungszentrum Jülich GmbH, and consider a wide range of stack designs, temperatures, and air absolute humidities. The simulation results demonstrate the potential of a protective coating produced through atmospheric plasma spraying (APS) technology in nearly eliminating chromium poisoning. It is also found that the APS protective coating could enable the operation of an SOFC stack with low requirements of air dehumidification at a temperature of 650 C.
22 January 2019 in Journal of Electrochemical Energy Conversion and Storage
A computational fluid dynamics model for high-temperature polymer electrolyte fuel cells (PEFC) is developed. This allows for three-dimensional (3D) transport-coupled calculations to be conducted. All major transport phenomena and electrochemical processes are taken into consideration. Verification of the present model is achieved by comparison with current density and oxygen concentration distributions along a one-dimensional (1D) channel. Validation is achieved by comparison with polarization curves from experimental data gathered in-house. Deviations between experimental and numerical results are minor. Internal transport phenomena are also analyzed. Local variations of current density from under channel regions and under rib regions are displayed, as are oxygen mole fractions. The serpentine gas channels contribute positively to gas redistribution in the gas diffusion layers (GDLs) and channels.