23 April 2020 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: The Neck Imaging Reporting and Data System was introduced to assess the probability of recurrence in surveillance imaging after treatment of head and neck cancer. This study investigated inter- and intrareader agreement in interpreting contrast-enhanced CT after treatment of oral cavity and oropharyngeal squamous cell carcinoma. MATERIALS AND METHODS: This retrospective study analyzed CT datasets of 101 patients. Four radiologists provided the Neck Imaging Reporting and Data System reports for the primary site and neck (cervical lymph nodes). The Kendall9s coefficient of concordance (W), Fleiss κ (κF), the Kendall9s rank correlation coefficient (τB), and weighted κ statistics (κw) were calculated to assess inter- and intrareader agreement. RESULTS: Overall, interreader agreement was strong or moderate for both the primary site (W = 0.74, κF = 0.48) and the neck (W = 0.80, κF = 0.50), depending on the statistics applied. Interreader agreement was higher in patients with proved recurrence at the primary site (W = 0.96 versus 0.56, κF = 0.65 versus 0.30) or in the neck (W = 0.78 versus 0.56, κF = 0.41 versus 0.29). Intrareader agreement was moderate to strong or almost perfect at the primary site (range τB = 0.67–0.82, κw = 0.85–0.96) and strong or almost perfect in the neck (range τB = 0.76–0.86, κw = 0.89–0.95). CONCLUSIONS: The Neck Imaging Reporting and Data System used for surveillance contrast-enhanced CT after treatment of oral cavity and oropharyngeal squamous cell carcinoma provide acceptable score reproducibility with limitations in patients with posttherapeutic changes but no cancer recurrence.
1 January 2022 in Dentomaxillofacial Radiology
Objectives: Accurate radiological differentiation of parotid tumors remains challenging despite recent technical advances in quantitative medical imaging. Multifrequency magnetic resonance elastography (MRE) could provide additional information on viscoelastic properties of normal and abnormal biological tissues. This study investigates the feasibility of MRE of the parotid glands in healthy participants and provides first reference values.Methods: 20 healthy participants underwent multifrequency MRE of both parotid glands at 3 Tesla. Shear waves at frequencies of 25, 30, 40, and 50 Hz were introduced into the participants' heads through the occiput using pressurized-air actuators. Shear wave speed (SWS) and loss angle of the shear modulus (φ) were reconstructed by tomoelastography post-processing as surrogate parameters for tissue stiffness and viscosity or fluidity. 10 participants underwent repeated MRE to determine test–retest reliability based on intraclass correlation coefficients.Results: All MRE datasets acquired could be included in the analysis. Mean SWS was 0.97 ± 0.13 m/s, and mean φ was 0.59 ± 0.05 rad, each for both sides combined and without notable lateral difference (p = 0.88/0.87). Test–retest reliability was good for SWS (ICC = 0.84 for both sides/ICC = 0.77 for the right side/ICC = 0.79 for the left side) and good to excellent for φ(ICC = 0.94/0.86/0.90).Conclusions: Multifrequency MRE of the parotid glands is feasible and reliable. This technique, therefore, is a promising method for investigating the viscoelastic properties of salivary gland tumors in future studies.
3 February 2021 in European Radiology
HBHans-Christian Bauknecht
+1
Objectives: To assess inter- and intrareader agreement of the Neck Imaging Reporting and Data System (NI-RADS) used in contrast-enhanced magnetic resonance imaging (MRI) including analysis of diffusion-weighted imaging (DWI), which is currently not part of the NI-RADS criteria. Methods: This retrospective study included anonymized surveillance contrast-enhanced MRI datasets of 104 patients treated for different head and neck cancers. Three radiologists experienced in head and neck imaging reported findings for the primary site and the neck using NI-RADS criteria in a first step and evaluated DWI sequences for the primary site in a second step. Thirty randomly selected imaging datasets were again presented to the readers. Kappa statistics and observed agreement (Ao) were calculated. Results: Interreader agreement across all MRI datasets was moderate (κFleiss = 0.53) for NI-RADS categories assigned to the primary site, substantial for NI-RADS categories of the neck (κFleiss = 0.67), and almost perfect for DWI of the primary site (κFleiss = 0.83). Interreader agreement for the primary site was particularly low in cases of cancer recurrence (κFleiss = 0.35) and when categories 2a, 2b, and 3 were combined (κFleiss = 0.30). Intrareader agreement was considerably lower for NI-RADS categories of the primary site (range Ao = 53.3–70.0%) than for NI-RADS categories of the neck (range Ao = 83.3–90.0%) and DWI of the primary site (range Ao = 93.3–100.0%). Conclusion: Interreader agreement of NI-RADS for reporting contrast-enhanced MRI findings is acceptable for the neck but limited for the primary site. Here, DWI has the potential to serve as a reliable additional criterion. Key Points: • NI-RADS was originally designed for contrast-enhanced computed tomography with or without positron emission tomography but can also be used for contrast-enhanced magnetic resonance imaging alone. • Overall interreader agreement was acceptable for NI-RADS categories assigned to the neck but should be improved for the primary site, where it was inferior to DWI; similar tendencies were found for intrareader agreement. • DWI is currently no criterion of NI-RADS, but has shown potential to improve its reliability, especially for categories 2a, 2b, and 3 of the primary site.
1 June 2019 in Acta Radiologica
Background: Computed tomography (CT) is widely used not only for diagnostic purposes but also for image guidance during different types of interventions. Therefore, radiation exposure of both patients and interventional radiologists remains a much-discussed topic. Purpose: To quantify radiation exposure of interventional radiologists during multiple CT-guided interventions using dosimeters placed under and outside standard protective lead clothing. Material and Methods: A total of 113 consecutive interventions covering three different types of procedures (grouped as periradicular infiltration therapy, biopsies, and drain placement) and performed using routine clinical protocols were prospectively analyzed. The interventions were performed by two radiologists of different experience levels with identically placed dosimeters outside and underneath their protective clothing. Personal doses (right hand, eye lens, thyroid gland, thorax, gonads) were cumulatively measured for each type of intervention and separately for the two radiologists. Results: Personal dose was below the detection limit of the dosimeters during periradicular infiltration therapy. In the biopsy and drain placement groups, the highest dose was found for the right hand (maximum cumulative dose = 1.84 ± 1.30 mSv in 19 consecutive drain placements). Under the protective gear, exposure was only observed for drain placements performed by the less experienced radiologist (maximum = 0.05 ± 0.04 mSv for the eye lens). Conclusion: Personal doses measured here were far below annual thresholds published by the International Commission on Radiological Protection. Therefore, performing multiple CT-guided interventions appears to be safe for interventional radiologists in terms of radiation exposure.
20 April 2017 in La radiologia medica
1 January 2022 in Dentomaxillofacial Radiology
Objectives: The Neck Imaging Reporting and Data System (NI-RADS) is an increasingly utilized risk stratification tool for imaging surveillance after treatment for head and neck cancer. This study aims to measure the impact of supervision by subspecialized radiologists on diagnostic accuracy of NI-RADS when initial reading is performed by residents. Methods: 150 CT and MRI datasets were initially read by two trained residents, and then supervised by two subspecialized radiologists. Recurrence rates by NI-RADS category were calculated, and receiver operating characteristic (ROC) curves were plotted. After dichotomization of the NI-RADS system (category 1 vs categories 2 + 3+4 and categories 1 + 2 vs 3 + 4), sensitivity, specificity, positive and negative predictive value were calculated. Results: 26% of the reports were modified by the supervising radiologists. Area under the curve of ROC plots values of the supervision session were higher than those of the initial reading session for both the primary site (0.89 vs 0.86) and the neck (0.94 vs 0.91), but the difference was not statistically significant. For dichotomized NI-RADS category assignments, differences between the initial reading and the supervision session were statistically significant regarding specificity and PPV for the primary site (1 + 2 vs 3 + 4 and 1 vs 2 + 3+4) or even for both sites combined (1 vs 2 + 3+4). Conclusion: NI-RADS enables trained resident radiologists to report surveillance imaging in patients with treated oral squamous cell carcinoma with high discriminatory power. Additional supervision by a subspecialized head and neck radiologist particularly improves specificity of radiological reports.