Background: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. Methods: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. Results: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13–2.23]; P =0.006). Conclusions: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.
1 June 2017 in International Journal of Cardiology
Despite recent improvements, inappropriate shocks emitted by implanted subcutaneous implantable cardioverter defibrillators (S-ICDs) remain a challenge in ‘real-life’ practice. We aimed to study the pre-implant factors associated with inappropriate shocks for the latest generation of S-ICDs. Three-hundred patients implanted with the third-generation S-ICD system for primary or secondary prevention between January 2017 and March 2020 were included in this multicentre retrospective observational study. A follow-up of at least 6 months and pre-implant screening procedure data were mandatory for inclusion. During a mean follow-up of 22.8 (±11.4) months, 37 patients (12.3%) received appropriate S-ICD shock therapy, whereas 26 patients (8.7%) experienced inappropriate shocks (incidence 4.9 per 100 patient years). The total number of inappropriate shock episodes was 48, with nine patients experiencing multiple episodes. The causes of inappropriate shocks included supraventricular arrhythmias (34.6%) and cardiac (30.7%) or extra-cardiac noise (38.4%) oversensing. Using multivariate analysis, we explored the independent factors associated with inappropriate shocks. These were the availability of less than three sensing vectors during pre-implant screening [hazard ratio (HR), 0.33; 95% confidence interval (CI), 0.11–0.93; P = 0.035], low QRS/T wave ratio in Lead I (for a threshold <3; HR, 4.79; 95% CI, 2.00–11.49; P < 0.001), history of supraventricular tachycardia (HR, 8.67; 95% CI, 2.80–26.7; P < 0.001), and being overweight (body mass index > 25; HR, 2.66; 95% CI, 1.10–6.45; P = 0.03). Automatic pre-implant screening data are a useful quantitative predictor of inappropriate shocks. Electrocardiogram features should be taken into consideration along with other clinical factors to identify patients at high risk of inappropriate shocks.
1 January 2023 in Circulation: Arrhythmia and Electrophysiology