14 February 2023 in IEEE Transactions on Transportation Electrification
Arcing in future high-voltage aerospace systems could occur more frequently and cause irreversible damage to electrical components, system structure and increase the risk of fire. While arcs seen in low-voltage aerospace systems tend to be long-duration and low-energy events, higher power but short-duration arcs may occur in high-voltage aerospace systems if they are readily detectable by system protection. This paper investigates the characteristics of high current arc faults generated at the AC frequencies expected in future rotating machines used for higher voltage aerospace systems. As such, arcs with a peak current up to 4.6 kA are generated at frequencies in the range of 0.5-2 kHz using an underdamped RLC circuit, under pressures of 0.2-1 bar absolute. High frequency arcs exhibit a similar characteristic to lower frequency arcs. A reduction in pressure results in lower arc voltage and arc power. Arcing tests at atmospheric pressure may therefore represent a worst-case scenario and the development of a low-pressure test environment may not be necessary. A black box model is developed to provide good agreement with experimental arc voltage waveforms for different parameters investigated in this study. This is a generalized modeling approach to estimate high-frequency high-voltage arcing characteristics without recourse to experiment.
15 October 2024 in IEEE Transactions on Industry Applications
Higher on-board electrical power generation is a promising solution to significantly reduce greenhouse gas emissions generated by the aviation industry. With the increasing level of operating voltages to meet the electrical power generation requirements and the higher system frequencies to optimize weight, arc faults will become a serious threat to future aircraft electrical systems. Other conditions such as short electrode gap, low relative humidity and low-pressure ambient environment will introduce additional technical challenges. To provide better understanding of electric arcs at aeronautical conditions, this paper investigates high current (1–1.7 kA) arcs at high frequencies (150–1000 Hz) for a range of electrode gap lengths between 2.5 and 40 mm under pressures between 0.2 to 1 bar absolute. The arc conductance, used as a parameter for comparison of arc characteristics across arc models, is found to increase at shorter gaps, lower pressures, higher humidities and lower frequencies. A black box model is used to demonstrate comparable simulated and experimental arc waveforms below the atmospheric pressure. This modeling approach provides good estimation of high-frequency high-voltage arcing characteristics under aerospace conditions without the need to perform extensive experimental testing.