Eric Arbes

Eric Arbes

Auto-generated profile, based on publicly available information

Eric Arbes

Division of Medical Physics, Department of Diagnostic and Interventional Radiology Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg Freiburg Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CSChristina Stengl
Christina Stengl
KPKathrin Panow
Kathrin Panow
EAEric Arbes
Eric Arbes
IMIván D Muñoz
Iván D Muñoz
JCJeppe Brage Christensen
Jeppe Brage Christensen
OJOliver Jäkel
Oliver Jäkel
Objective . Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs’ motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphic P ancreas P hantom for I on-b e am T herapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy. Approach . The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs’ organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients’ 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films. Main results . PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude. Significance . A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests.

17 April 2024 in Medical Physics
Verified
Journal Article
Open access
CSChristina Stengl
Christina Stengl
IMIván D. Muñoz
Iván D. Muñoz
EAEric Arbes
Eric Arbes
EREvelyn Rauth
Evelyn Rauth
JCJeppe Brage Christensen
Jeppe Brage Christensen
JSJoao Seco
Joao Seco
Background: Particle mini‐beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing‐induced organ motion affects particle mini‐beam irradiation schemes since the organ displacements exceed the mini‐beam structure dimensions, decreasing the advantages of spatial fractionation.Purpose: In this study, the impact of breathing‐induced organ motion on the dose distribution was examined at the target and organs at risk(OARs) during carbon ion mini‐beam irradiation for pancreatic cancer.Methods: As a first step, the carbon ion mini‐beam pattern was characterized with Monte Carlo simulations. To analyze the impact of breathing‐induced organ motion on the dose distribution of a virtual pancreas tumor as target and related OARs, the anthropomorphic Pancreas Phantom for Ion beam Therapy (PPIeT) was irradiated with carbon ions. A mini‐beam collimator was used to deliver a spatially fractionated dose distribution. During irradiation, varying breathing motion amplitudes were induced, ranging from 5 to 15 mm. Post‐irradiation, the 2D dose pattern was analyzed, focusing on the full width at half maximum (FWHM), center‐to‐center distance (ctc), and the peak‐to‐valley dose ratio (PVDR).Results: The mini‐beam pattern was visible within OARs, while in the virtual pancreas tumor a more homogeneous dose distribution was achieved. Applied motion affected the mini‐beam pattern within the kidney, one of the OARs, reducing the PVDR from 3.78 0.12 to 1.478 0.070 for the 15 mm motion amplitude. In the immobile OARs including the spine and the skin at the back, the PVDR did not change within 3.4% comparing reference and motion conditions.Conclusions: This study provides an initial understanding of how breathing‐induced organ motion affects spatial fractionation during carbon ion irradiation, using an anthropomorphic phantom. A decrease in the PVDR was observed in the right kidney when breathing‐induced motion was applied, potentially increasing the risk of damage to OARs. Therefore, further studies are needed to explore the clinical viability of mini‐beam radiotherapy with carbon ions when irradiating abdominal regions.

19 July 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
EAEric Arbes
Eric Arbes
AHAriel Hannum
Ariel Hannum
JFJohannes Fischer
Johannes Fischer
QCQingping Chen
Qingping Chen
SLSebastian Littin
Sebastian Littin
SRSimon Reiss
Simon Reiss
Purpose: To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods: Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers. DTI and SNR analysis was performed to investigate protocol efficacy. Results: The sequences performed well at the task of imaging short axis views of the myocardium and producing data suitable for diffusion tensor imaging analysis. Significant differences in sequence performance across different systems and within the same system were revealed. Relative SNR utilizing the strongest available gradient system yielded up to 80% more SNR than the weakest tested system. Relative SNR obtained from the same sequence at different scanners differed by up to 42%, suggesting hardware impacts that warrant further investigation. Conclusion: The presented sequence framework allows for an easy starting point into cardiac diffusion tensor imaging and opens the door to further analysis of hardware impacts on performance.