Ekene Samuel Mbonu

Ekene Samuel Mbonu

Auto-generated profile, based on publicly available information

Ekene Samuel Mbonu

Mechatronics Engineering Department, School of Electrical Systems Engineering, Federal University of Technology Owerri, Owerri PMB 1526, Imo State, Nigeria

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2026 in Journal of Advanced Science and Optimization Research
Verified
Journal Article
Open access
PDF file
PEPaulinus Chinaenye Eze
Paulinus Chinaenye Eze
OOOndoma James Onojo
Ondoma James Onojo
Jude-Kennedy Chibuzo ObichereJude-Kennedy Chibuzo Obichere
Jude-Kennedy Chibuzo Obichere
EMEkene Samuel Mbonu
Ekene Samuel Mbonu
A new Model Reference Adaptive Control (MRAC) based on minimizing Integral Time Absolute Error (ITAE) model criterion has been designed. However, an obvious challenge to the performance of the ITAE-MRAC method is poor rise time and settling time in positioning control of dish antenna. Thus, Fuzzy Logic Controller (FLC) and Fuzzy-Proportional Derivative plus Integral (Fuzzy-PD+I) controller were designed. The primary purpose of this work is to use intelligent based multi-loop control strategy to achieve efficient positioning control for satellite antenna. Two control strategies were proposed by separately integrating ITAE-MRAC model with FLC and Fuzzy-PD+I controllers. This resulted in multi-loop control systems in which the ITAE-MRAC model forms the outer loop whose output based on the adjustment mechanism was used to adjust the control dynamic of the inner (or secondary) loop controller (FLC or Fuzzy-PD+I). The use of multi-loop makes the inner loop more stable and efficient in providing improved tracking response to setpoint signal. The control models based on PID, ITAE-MRAC, FLC, Fuzzy-PD+I, ITAE-MRAC-FLC, and ITAE-MRAC-Fuzzy-PD+I were separately applied to the dish antenna positioning system. The results obtained from the controllers indicated that the rise times and settling times were improved including good overshoots respectively with zero steady-state error in all cases. The percentage improvement over FLC and Fuzzy-PD+I revealed 30% and 4.95% reduction in rise times and 22% and 1.62% reduction in settling times using ITAE-MRAC-FLC and ITAE-MRAC-Fuzzy-PD+I, respectively. Generally, the results indicated that the use of the ITAE based MRAC model enhanced the performances of the FLC and Fuzz-PD+I, and the overall transient and steady-state response dynamic characteristics of the dish antenna positioning system.

4 August 2026 in Thermal Science and Applications
Verified
Journal Article
Open access
PDF file
NONnamdi V. Ogueke
Nnamdi V. Ogueke
EMEkene S. Mbonu
Ekene S. Mbonu
VJVictor A. Jumbo
Victor A. Jumbo
DNDesmond O. Nwadike
Desmond O. Nwadike
JNJanuarius C. Njoku
Januarius C. Njoku
DODamaris A. Onyebuchulam
Damaris A. Onyebuchulam
Evaporative cooling is one method that could help reduce post-harvest losses. However, its increased acceptability has been hindered by its poor performance in humid regions or during humid periods of the day or year, resulting in its inability to produce cooling during those periods. To address this challenge, an enhanced evaporative cooler for the preservation of fruits and vegetables was designed and tested. The system, an active direct evaporative cooler type, incorporated desiccant (activated carbon) and addressed the challenge of frequent desiccant saturation by using a sensor to control the regeneration process. Its major components are a desiccant wheel made of galvanised steel sheet, driven by a 12 V DC motor; a 220 V, 0.14 A-rated extractor fan; a 12 V DC, 70 W adsorbent regeneration heater-fan assembly; a humidification pad; and a water tank. Activated carbon was used as the desiccant. From the results obtained, when the system was tested during humid periods, the storage chamber temperature was maintained below the ambient value throughout the experimental periods, with an average difference of 4.14–5.13 °C. The average cooling power was 259–323 W, while the average COP was 2.95–3.67. Relative humidity within the storage chamber remained above 88% throughout the period. Thus, the designed system can produce cooling, even in a very humid region.