Modular multilevel converters (MMCs) require well-balanced submodule (SM) capacitor voltages at the reference value for satisfactory steady-state and dynamic operations. Achieving this goal in hybrid MMCs, where the modulation index exceeds one, becomes intricate owing to the differing participation of half-bridge submodules (HB-SMs) and full-bridge submodules (FB-SMs) in arm voltage generation. This article proposes an advanced voltage-balancing method based on enhanced phase-shift modulation and model predictive control, featuring a single comprehensive cost function that utilizes a novel form of redundancy to manage the insertion of HB- and FB-SMs in a wide range of modulation indices. The designed cost function addresses four key control objectives: intercell balancing by tracking the dc voltage reference, minimizing the energy deviation between the HB- and FB-SMs, interleg balancing to eliminate energy variations between the upper and lower arms, and rejecting voltage errors arising from uncertainties in the SM capacitance using a Kalman filter based observer. This method enables comprehensive capacitor voltage balancing, which is suitable for various modulation indices and power factors. The validity of the proposed method is substantiated through simulations using MATLAB/Simulink software and experiments conducted on a scaled-down hardware prototype.
18 June 2025 in IEEE Transactions on Industrial Electronics
In this article, the hybrid modulated model predictive control (HM2PC) method for the hybrid modular multilevel converter (hybrid-MMC) in high voltage direct current (HVDC) applications is introduced to improve the fault ride-through (FRT) capabilities on the direct current side (DCS). For the studied system, compared to conventional PI-based control method under DC short-circuit fault (DC-SCF) conditions, the proposed HM2PC demonstrates faster dynamics, lower dc and arm over-currents (reduced by 62% and 47%, respectively), moderate voltage fluctuations in submodule capacitors, and lower fault clearing (FC) time (reduced by 48%). While HM2PC shares the advantage of rapid dynamic response with model predictive control (MPC) techniques during fault conditions, it offers additional benefits over direct (DMPC) and indirect MPC (IMPC) methods, such as reduced computational complexity, independence from the converter's number of levels, and the elimination of the need for weighting factor tuning. As a result, the proposed method combines fast dynamic performance in DC-SCF conditions with ease of implementation on digital standard platforms. To validate the proposed method under DC-SCF conditions, simulations are conducted based on real high-power HVDC applications and MTDC grids in MATLAB/simulink. For comparing and experimental validation, the proposed HM2PC, IMPC, and conventional PI-based methods have been implemented on a five-level (5L) hybrid-MMC setup based on ZYNQ module hardware in DC-SCF conditions, and the results confirm the claims.
Background: Heat is one of the harmful physical factors in the workplace. Occupational heat stress refers to the net load that the workers should put up with as a result of the combined impact of metabolic heat, environmental factors, and clothing causing heat storage in the body. Objectives: This study aimed to compare the correlation between environmental stress index (ESI) and other thermal indices including wet-bulb globe temperature (WBGT), wet-bulb dry temperature (WBDT), thermal work limit (TWL), heat index (HI), standard effective temperature (SET), and physiological equivalent temperature (PET). Methods: Data were collected from 30 workers in one pelletizing factory located in southeastern Iran. The measurement of environmental variables and workers’ physiological responses at the workplace was implemented in 10 conditions. Pearson product-moment correlation coefficient and linear regression were utilized to determine the relationship between ESI and environmental/physiological variables. Results: The results showed that the strongest correlation was recorded between ESI and dry temperature (r = 0.96), natural wet temperature (r = 0.96), and heart rate in the working condition (r = 0.94). ESI was strongly correlated with WBDT (r = 0.99) and WBGT (r = 0.98). Conclusions: It is concluded that ESI is strongly related to heat indices (WBGT, WBDT, TWL, HI, SET, PET, PSI, and PSIHR) and heat stress was higher than the legitimate range in some of the working stations. The highest coefficient was recorded for the relationship between ESI and WBDT. Keywords: Dry Temperature; Heat; Heat Stress; Physiological Strain; Environmental Stress Index
1 July 2026 in IEEE Transactions on Industrial Electronics
The hybrid modular multilevel converter (Hybrid-MMC) integrates half-bridge and full-bridge sub-modules (HBSMs and FBSMs) to improve operational flexibility in high voltage direct current (HVDC) applications. Owing to this hybrid configuration, the converter can withstand wide DC-side (DCS) voltage variations, ranging from nominal levels to DC short-circuit fault (DC-SCF) conditions. By incorporating approximately 50% FBSMs, the Hybrid-MMC can block DC-SCFs, sustain reactive power exchange, and operate under reduced DCS voltage conditions. However, under DC-SCF conditions, excessive DCS and arm currents, along with overvoltages across FBSM capacitors, may arise. Such conditions can overstress semiconductor devices and capacitors in submodule (SM) devices and pose a risk to DCS equipment. To enhance transient fault ride-through (FRT) capability, this article proposes a hybrid modulated model predictive control (HM2PC) strategy based on a three-phase Hybrid-MMC model (TP-HM2PC). The proposed method reduces DCS fault current by about 12.5%, arm overcurrents by 20%, and fault clearing time by 3% compared with the per-phase HM2PC (PP-HM2PC) approach. In addition, a systematic closed-loop second-harmonic circulating current injection (SCL-SHCC) method is introduced to mitigate capacitor voltage instability under overmodulation conditions. The combination of TP-HM2PC and SCL-SHCC ensures stable converter operation even under severe overmodulation, using only 25% of the FBSMs. The effectiveness of the proposed control methods is validated through comprehensive MATLAB/Simulink simulations. Furthermore, experimental tests are conducted on a five-level Hybrid-MMC prototype implemented on a ZYNQ-based hardware platform.