Amit Banerjee

Amit Banerjee

Auto-generated profile, based on publicly available information

Amit Banerjee

Department of Micro Engineering, Kyoto University, Kyoto, Japan

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2018 in Science
Verified
Journal Article
Closed access
PDF file
ABAmit Banerjee
Amit Banerjee
DBDaniel Bernoulli
Daniel Bernoulli
HZHongti Zhang
Hongti Zhang
MYMuk-Fung Yuen
Muk-Fung Yuen
JLJiabin Liu
Jiabin Liu
SSSubra Suresh
Subra Suresh
Small, smooth, and bendable diamonds: If you manage to deform a diamond, it usually means you have broken it. Diamonds have very high hardness, but they do not deform elastically. This limits their usefulness for some applications. However, Banerjee et al. discovered that diamond nanoneedles can deform elastically after all (see the Perspective by LLorca). The key was in their small size (300 nm), which allowed for very smooth-surfaced, defect-free diamonds. The deformation was close to the theoretical limit for diamond, which opens up the potential for applications in microelectronics and drug delivery. Science , this issue p. 300 ; see also p. 264

1 October 2009 in Applied Surface Science
Verified
Journal Article
Closed access
NSNeeraj Shukla
Neeraj Shukla
STSarvesh K. Tripathi
Sarvesh K. Tripathi
ABAmit Banerjee
Amit Banerjee
ARA. Sai Venkata Ramana
A. Sai Venkata Ramana
NRNitul S. Rajput
Nitul S. Rajput
VKVishwas N. Kulkarni
Vishwas N. Kulkarni

4 November 2011 in Nanotechnology
Verified
Journal Article
Closed access
NRNitul S Rajput
Nitul S Rajput
ABAmit Banerjee
Amit Banerjee
HVH C Verma
H C Verma
Electron-and ion-induced bending (EIB/IIB) phenomena have been studied in self-supported polycrystalline metallic and metal-amorphous bilayered nanocantilevers. The experiments reveal many interesting facts regarding electron/ion-matter interaction, which builds a proper foundation for the understanding of the phenomenon. The mechanism for bending of metallic cantilevers has been proposed to be primarily due to void-induced stress generation during ion beam irradiation. On the other hand, thermal effects have been found to play the dominant role in the case of bending of bilayer (amorphous-metal) nanocantilevers. The instantaneous, reversible, highly controllable and permanent nature of the process has been exploited to fabricate several complicated nanostructures in three dimensions. IIB of the fabricated cantilevers is shown to have a high precession mass sensing aptitude, capable of detecting a change in mass of the order of femtograms.

1 January 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
YAYuki Akura
Yuki Akura
YIYasuaki Ikeda
Yasuaki Ikeda
YMYuki Matsunaga
Yuki Matsunaga
MSMasaki Shimofuri
Masaki Shimofuri
ABAmit Banerjee
Amit Banerjee
JHJun Hirotani
Jun Hirotani
The measurement of thermal conductivities of anisotropic materials and atomically thin films is pivotal for the thermal design of next-generation electronic devices. Frequency-domain thermoreflectance (FDTR) is a pump–probe technique that is known for its accurate and straightforward approach to determining thermal conductivity and stands out as one of the most effective methodologies. Existing research has focused on advancing a measurement system that incorporates beam-offset FDTR. In this approach, the irradiation positions of the pump and probe lasers are spatially offset to enhance sensitivity to in-plane thermal conductivity. Previous implementations primarily adjusted the laser positions by modifying the mirror angle, which inadvertently distorted the laser spot. Such distortion significantly compromises measurement accuracy, which is especially critical in beam-offset FDTR, where the spot radius has a crucial impact on measured values. This study introduces an advanced FDTR measurement system that realizes probe laser offset without inducing spot distortion, utilizing a relay optical system. The system was applied to measure the thermal conductivities of both isotropic standard materials and anisotropic samples, including highly oriented pyrolytic graphite and graphene. The findings corroborate those of prior studies, validating the measurement’s reliability in terms of sensitivity. This development of a beam-offset FDTR system without laser spot distortion establishes a robust basis for accurate thermal conductivity values of anisotropic materials via thermoreflectance methods.

4 August 2009 in Nanotechnology
Verified
Journal Article
Closed access
ABAmit Banerjee
Amit Banerjee
TMTarun Mankad
Tarun Mankad
SDS Dhamodaran
S Dhamodaran
JRJ Ramkumar
J Ramkumar
VKV N Kulkarni
V N Kulkarni
We present a 'universal' phenomenon of mass accumulation and its sensing on nanostructures due to electron beam cracking of residual gas molecules during electron beam scanning. Though the extent of this phenomenon is limited to a very small increment in mass or thickness, it has significant implications for both the scientific and technological aspects of almost all processes in the nanodomain. Mass accumulation in every frame scan (or per second) is of the order of a few attograms and the thickness of deposition is of the order of picometre (fraction of a monolayer) only. Direct measurement of a mass or thickness of this order is difficult. Nanopillars having a high resonance 'Q-factor' have been successfully exploited for such high precision measurements. The mass accumulation rate has been characterized with respect to (i) electron energy and beam current, (ii) environment within the chamber (presence or absence of a precursor gas) and (iii) partial exposure of the nanopillars to the e-beam.

19 April 2016 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ABAmit Banerjee
Amit Banerjee
CJChenchen Jiang
Chenchen Jiang
LLLokesh Lohiya
Lokesh Lohiya
Yong YangYong Yang
Yong Yang
Yang LuYang Lu
Yang Lu
Plastic deformation in metallic glasses is highly localized and often associated with shear banding, which may cause momentary release of heat upon fracture. Here, we report an explosive fracture phenomenon associated with momentary (∼10 ms) light emission (flash) in Lanthanum-based (LaAlNi) metallic glass microwires (dia. ∼50 μm) under quasi-static tensile loading. The load-displacement data as well as the visual information of the tensile deformation process were acquired through an in situ measurement set-up, which clearly showed nonlinear stress (σ)–strain (ϵ ) curves prior to yielding and also captured the occurrence of the flash at high fracture stresses (∼1 GPa). Through the postmortem fractographic analysis, it can be revealed that the fracto-emission upon quasi-static loading could be mainly attributed to the localized adiabatic work accumulated at a very large elastic strain confined within the microscale sample volume, followed by a localized high temperature rise up to ∼1000 K at the fracture surface through localized energy dissipation. Our findings suggest that the La-based metallic glass microwires could be useful for energetic microchips, micro-ignition devices, and other functional applications.