Galen D. Reed

Galen D. Reed

Auto-generated profile, based on publicly available information

Galen D. Reed

GE Healthcare, Dallas, TX 75390, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2020 in Circulation Research
Verified
Journal Article
Closed access
PDF file
JPJae Mo Park
Jae Mo Park
GRGalen D. Reed
Galen D. Reed
JLJeff Liticker
Jeff Liticker
William C. (Trey) PutnamWilliam C. (Trey) Putnam
William C. (Trey) Putnam
ACAlvin Chandra
Alvin Chandra
VZVlad G. Zaha
Vlad G. Zaha

28 November 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
CMCornelius von Morze
Cornelius von Morze
JEJohn A. Engelbach
John A. Engelbach
TBTyler Blazey
Tyler Blazey
JQJames D. Quirk
James D. Quirk
GRGalen D. Reed
Galen D. Reed
JGJoel R. Garbow
Joel R. Garbow

5 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
GRGalen D. Reed
Galen D. Reed
JMJunjie Ma
Junjie Ma
JPJae Mo Park
Jae Mo Park
RSRolf F. Schulte
Rolf F. Schulte
CHCrystal E. Harrison
Crystal E. Harrison
CMCraig R. Malloy
Craig R. Malloy

15 September 2021 in Tomography
Verified
Journal Article
Open access
PDF file
TBTyler Blazey
Tyler Blazey
GRGalen D Reed
Galen D Reed
Joel GarbowJoel Garbow
Joel Garbow
CMCornelius von Morze
Cornelius von Morze
Although hyperpolarization (HP) greatly increases the sensitivity of 13C MR, the usefulness of HP in vivo is limited by the short lifetime of HP agents. To address this limitation, we developed an echo-planar (EPI) sequence with spectral-spatial radiofrequency (SSRF) pulses for fast and efficient metabolite-specific imaging of HP [1-13C]pyruvate and [1-13C]lactate at 4.7 T. The spatial and spectral selectivity of each SSRF pulse was verified using simulations and phantom testing. EPI and CSI imaging of the rat abdomen were compared in the same rat after injecting HP [1-13C]pyruvate. A procedure was also developed to automatically set the SSRF excitation pulse frequencies based on real-time scanner feedback. The most significant results of this study are the demonstration that a greater spatial and temporal resolution is attainable by metabolite-specific EPI as compared with CSI, and the enhanced lifetime of the HP signal in EPI, which is attributable to the independent flip angle control between metabolites. Real-time center frequency adjustment was also highly effective for minimizing off-resonance effects. To the best of our knowledge, this is the first demonstration of metabolite-specific HP 13C EPI at 4.7 T. In conclusion, metabolite-specific EPI using SSRF pulses is an effective way to image HP [1-13C]pyruvate and [1-13C]lactate at 4.7 T.

4 January 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
SKShun Kishimoto
Shun Kishimoto
JBJeff Brender
Jeff Brender
SMShingo Matsumoto
Shingo Matsumoto
TSTomohiro Seki
Tomohiro Seki
NONobu Oshima
Nobu Oshima
MKMurali C. Krishna
Murali C. Krishna
Metabolic differences between patients and within the tumor itself can be an important determinant in cancer treatment outcome. However, methods for determining these differences non-invasively in vivo have been lacking. Using pancreatic ductal adenocarcinoma as a model, we demonstrate that tumor xenografts with a similar genetic background can be distinguished by their differing rates of metabolism, as detected by imaging of uniformly 13 C labeled glucose tracers using a newly developed technique using tensor decomposition for noise suppression to bring the signal to a detectable level without hyperpolarization of the tracer. Using this method, cancer subtypes that appeared to exhibit similar metabolic profiles by other techniques that measured steady state metabolism can be distinguished.