Electrical machines for transportation applications need to be highly reliable, particularly if they drive safety-critical systems. At the same time, another main requirement is represented by the significant torque density, especially for aerospace, where weight constraints are extremely stringent. For achieving high peak torque, an effective strategy consists in supplying the windings with a current greater than the rated value; thus, thermally overloading the machine for limited time periods. However, if the insulation is overheated, the machine lifetime is shortened and reliability issues can arise. This paper experimentally investigates the influence of short-time thermal overload on the insulation lifetime for low voltage, random wound electrical machines. The analysis is performed on round enamelled magnet wire coils, which are aged by accelerated thermal cycles. The obtained results are statistically processed through a two parameter Weibull distribution. According to the findings of the experimental data post processing, a lifetime prediction model is built. This model is employed for predicting the lifetime consumption of a motor embedded into an electromechanical actuator for aerospace application.
This paper focuses on the inception of partial discharges within the insulation system of electrical actuators used for the More Electrical Aircraft (MEA). Since these machines should operate in the absence of Partial Discharges (PDs), the dependence of the PD Inception Voltage (PDIV) on voltage impulses typical of wide bandgap (SiC) devices is investigated at both 1 bar, reduced pressures close to those typical of aircraft cruising altitudes (150 mbar - 200 mbar) or lower (down to 5 mbar). Propagation issues are not dealt with here as results were obtained working on insulation models consisting of couples of wires twisted together (twisted pairs), thus knowing exactly the potential differences between all points of the insulation model. The results show that the rise times and the switching frequencies associated with wide bandgap devices have little impact on the PDIV. A model able to predict the PDIV of the turn/turn insulation of random wound motors (the most vulnerable part of the insulation) at different pressures is proposed. The model is also able to deal with temperature changes, with limitations that depend on the type on insulation systems.
13 July 2018 in IEEE Transactions on Dielectrics and Electrical Insulation
The reliability of low-voltage inverter-fed motors is highly dependent on the inception of partial discharges. The effect of impulsive waveform parameters must be investigated to predict the repetitive partial discharge inception voltage (RPDIV) and define test procedures that can indicate properly the behavior in service of the insulation system. This paper focuses on the RPDIV of magnet wires using twisted pairs subjected to repetitive unipolar impulsive voltage waveforms. The effects of supply frequency (5 to 200 kHz) at pressure levels that are typical for aircraft (20 to 100 kPa) is examined. Results show that RPDIV steadily decreases with frequency up to 100 kHz where it reaches a plateau. This behavior is explained as an effect of the oscillations that inevitably exist in the applied voltage waveform. Therefore, a conservative estimate of the RPDIV could be achieved by raising the supply frequency well above the operation frequency. In the experiments, the RPDIV is decreasing linearly with pressure. If this behavior could be confirmed for other insulation systems, the design of systems working at pressures typical of aircraft would result relatively easy.
12 April 2019 in IEEE Electrical Insulation Magazine
This paper proposes a model to determine the partial discharge inception voltage of magnet wires, including the effect of elevated temperatures, and shows its applicability to the complete range of wire geometries considered in IEC Standard 60317-13.
In this paper, the results obtained from lab tests on twisted pairs subjected to different voltage waveforms and atmospheric conditions are used to propose how to modify the IEC Std. 60034-18-41. The goal is to make the standard suitable for the More Electrical Aircraft (MEA). The results show that it is initially necessary to screen out materials through simple tests. The enhancement factors for temperature can be modified to consider reduced pressures and temperatures using a simple model. The aging enhancement factor can be reduced considering the reduced sensitivity of the partial discharge inception voltage (PDIV) at low pressures on the enamel thickness. Eventually, reference will be made to the drive discussed in Part I of this series to draw conclusions about the likelihood of partial discharge inception in a random wound stator and how to reduce it by modifying either the inverter or the stator insulation. Reference to a random wound motor is made throughout the paper.
According to the IEC 60034-18-41, the reliability of inverter-fed motor electrical insulation must be assessed through qualification tests with stress levels based on empirical assumptions. For purely organic (Type 1) electrical insulation systems, the inception of partial discharges within the insulation systems is the end-life criterion. The aim of this paper is to start a work in the direction of proposing a framework for designing from scratch motor insulation systems with partial discharge inception voltage adequate for inverter applications. To achieve this purpose, inception voltage estimates obtained using streamer inception criteria were compared with measurements performed in the lab. The results show that, for a large class of magnet wires, conservative estimates can be obtained.