Leshan Sun

Leshan Sun

Auto-generated profile, based on publicly available information

Leshan Sun

University of California, Irvine

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2024 in Science Advances
Verified
Journal Article
Open access
SWSiqi Wang
Siqi Wang
PPPrabodh Kumar Pandey
Prabodh Kumar Pandey
GLGerald Lee
Gerald Lee
RBRick J. P. van Bergen
Rick J. P. van Bergen
LSLeshan Sun
Leshan Sun
LXLiangzhong Xiang
Liangzhong Xiang
Computed tomography (CT) scanners are essential for modern imaging but require around 600 projections from various angles. We present x-ray–induced acoustic computed tomography (XACT), a method that uses radiation-induced acoustic waves for three-dimensional (3D) x-ray imaging. These spherical acoustic waves travel through tissue at 1.5 × 10 3 meters per second, much slower than x-rays, allowing ultrasound detectors to capture them and generate 3D images without mechanical scanning. We validate this theory by performing 3D numerical reconstructions of a human breast from a single x-ray projection and experimentally determining 3D structures of objects at different depths. Achieving resolutions of 0.4 millimeters in the XZ plane and 3.5 millimeters in the XY plane at a depth of 16 millimeters, XACT demonstrates the ability to produce 3D images from one x-ray projection, reducing radiation exposure and enabling gantry-free imaging. XACT shows great promise for biomedical and nondestructive testing applications, potentially replacing conventional CT.

13 January 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
YXYifei Xu
Yifei Xu
YSYuchen Song
Yuchen Song
LSLeshan Sun
Leshan Sun
Zhongping ChenZhongping Chen
Zhongping Chen
LXLiangzhong Xiang
Liangzhong Xiang
Electroacoustic imaging is an imaging modality used to detect electric field energy distribution during electroporation, offering valuable guidance for clinical procedures, particularly in deep tissues. Traditionally, single-element piezoelectric transducers or arrays have been employed for this purpose. However, these piezoelectric sensors are sensitive to electromagnetic interference and require physical contact with the sample through a coupling medium, raising concerns for both clinical and preclinical applications. To overcome these limitations, a multi-channel random quadrature ultrasonics system has been developed, enabling non-contact detection of electroacoustic signals. In this study, we demonstrated that this non-contact technique effectively detects electroacoustic signals, identifies electroporation regions, and reconstructs electric energy distribution, offering a promising approach for monitoring electroporation therapy.

17 February 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
PPPrabodh Kumar Pandey
Prabodh Kumar Pandey
GGGilberto Gonzalez
Gilberto Gonzalez
KBKristina Bjegovic
Kristina Bjegovic
LSLeshan Sun
Leshan Sun
YCYong Chen
Yong Chen
LXLiangzhong Xiang
Liangzhong Xiang
We propose protoacoustic radiography (PAR), an imaging modality combining proton excitation and acoustic detection for three-dimensional (3D) imaging from a single proton projection. PAR avoids the effect of multiple Coulomb scattering in imaging by detecting ultrasound. Proton-induced acoustic waves propagate spherically, enabling 3D imaging from a single projection. Additionally, the distinctive feature of proton beams—concentrating energy deposition primarily at the Bragg peak—allows for precise depth-selectivity through proton energy tuning. We performed PAR using clinical proton machines, and our results demonstrate the capability of PAR to reconstruct targets at various depths (between ∼20 and 23 cm) with an axial resolution of 1.3 mm by fully leveraging the Bragg peak and by tuning the kinetic energy of the proton beam. PAR offers opportunities for precise structural determination with protons both in biomedicine and nondestructive testing.

21 October 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
LSLeshan Sun
Leshan Sun
YXYifei Xu
Yifei Xu
PPPrabodh Kumar Pandey
Prabodh Kumar Pandey
LXLiangzhong Xiang
Liangzhong Xiang
Osteoporosis is a significant public health concern that affects old adults and individuals with certain medical conditions. In this work, we demonstrate the proof of the principle of combining the emerging new radiological imaging technique, X-ray-induced acoustic (XA) imaging, and X-ray computed tomography (CT) for bone density and elasticity evaluation. This combined method is intended for use in single scanner that can perform both XA imaging and CT imaging simultaneously for the purpose of providing accurately registered anatomical localization of structures seen in the CT image to extract the elasticity information in XA imaging. We demonstrate that our nonlinear optimization algorithm can acquire the speed of sound information for bone. By combining the speed of sound and density information from CT, we can calculate the elasticity with an error of less than 1%. We conclude that using CT information as prior information is a feasible way to obtain elasticity information in XA imaging. These findings enable more accurate osteoporosis diagnosis through both bone density and bone strength evaluation using one integrated system in the future.

25 September 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
YLYankun Lang
Yankun Lang
JBJadon Buller
Jadon Buller
YXYifei Xu
Yifei Xu
LSLeshan Sun
Leshan Sun
ZJZhuoran Jiang
Zhuoran Jiang
LRLei Ren
Lei Ren
Objective. To overcome the limitations of electroacoustic tomography (EAT) in clinical settings-particularly the artifacts and distortions caused by limited-angle data acquisition-and enable accurate, efficient visualization of electric field distributions for electroporation-based therapies. Approach. We developed a deep learning-based framework that enhances 3D EAT image reconstruction from single-view projections by leveraging the large foundation model (LFM) SAM-Med3D. The encoder was modified into a local-global feature fusion architecture that extracts multi-scale features from intermediate transformer layers, preserving fine structural details while maintaining computational efficiency. A lightweight decoder with progressive up-sampling and skip connections was employed to generate high-resolution images, addressing limitations of conventional U-Net architectures. Main results. We collected a dataset of 50 EAT scans-each with 120 views-for a total of 6000 views. These were acquired from water phantoms and tissue samples under varied electrode configurations and voltages, and split into training (30 scans, 3600 views), validation (10 scans, 1200 views), and testing (10 scans, 1200 views). Our model significantly outperformed baseline 3D U-Nets, achieving an RMSE of 0.0092, PSNR of 41.10, and SSIM of 0.9377. Remarkably, our method reconstructs a full-view 3D EAT image from a single view in just 2 s, demonstrating its potential for near real-time monitoring and adaptive dose verification in electroporation-based therapies. Significance. This is the first application of a LFM like SAM-Med3D for enhancing 3D EAT imaging. The proposed framework addresses the critical challenge of limited-angle data in EAT and demonstrates strong potential for improving precision and safety in electroporation-based therapies, thereby advancing the technique’s clinical viability.

1 November 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
YLYankun Lang
Yankun Lang
LSLeshan Sun
Leshan Sun
KBKristina Bjegovic
Kristina Bjegovic
LRLucia Rodriguez-Gonzalez
Lucia Rodriguez-Gonzalez
ZJZhuoran Jiang
Zhuoran Jiang
LRLei Ren
Lei Ren
Protoacoustic (PA) imaging captures acoustic signals generated during proton interactions and shows strong potential for real-time monitoring of dose distribution, addressing the challenges in proton therapy where accuracy can be affected by patient positioning and anatomical changes. This study investigates the use of SAM-Med3D, a large-scale 3D segmentation model, to enhance PA image reconstruction and address the limited-angle problem that impairs spatial resolution. We modified the SAM-Med3D architecture by introducing a global-local feature fusion strategy in the encoder to preserve structural details and replacing the prompt-based decoder with a lightweight design that progressively restores image resolution. The method was evaluated using a dataset of prostate cancer patients, incorporating CT images and clinical treatment plans, as well as an experimental pencil beam dataset in a water tank. Our model achieved significant improvements over baseline methods, with average RMSE and SSIM values of 0.017 and 0.958 for image reconstruction, and 0.013 and 0.963 for dose verification, respectively (p < 0.05). Gamma index evaluation showed high agreement (over 97%) between predicted and ground truth dose maps. The method took approximately 1 second per patient, supporting its feasibility for online 3D dose verification. Results show proposed method provides an effective solution to the limited-angle challenge in PA imaging and contributes to the development of high-precision, real-time 3D dose verification in proton therapy. It also underscores the potential of large-scale models like SAM-Med3D for advancing image enhancement techniques in medical imaging, particularly in the context of real-time radiation therapy monitoring.