K. Ramya

K. Ramya

Auto-generated profile, based on publicly available information

K. Ramya

Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, India

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KRK. Ramya
K. Ramya
ATAditya Tiwari
Aditya Tiwari
PSP. N. Sidhartha
P. N. Sidhartha
SKSayan Kanungo
Sayan Kanungo
Karumbaiah ChappandaKarumbaiah Chappanda
Karumbaiah Chappanda
An electrochemical biosensor based on a 2D tungsten diselenide (WSe 2 ) nano-flakes electrode was developed for highly selective detection of dopamine. The dopamine sensors were fabricated by modifying carbon cloth with optimized loading of tungsten diselenide nano-flakes. The material properties and sensor characterization were investigated by Scanning electron microscopic, x-ray diffraction, x-ray photoelectron spectroscopy, ultraviolet-visible spectroscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and Mott-Schottky analysis. The sensor exhibited a large active working area with an average sensitivity of 1.6325 μA μM -1 cm 2 and a normalized sensitivity of 0.16 μM -1 with a limit of detection of 4 nM. The sensors were highly selective with respect to sucrose, L-cysteine, uric acid, Glucose, ascorbic acid, and Fructose.

25 June 2024 in IEEE Open Journal of Nanotechnology
Verified
Journal Article
Open access
KLK S Jaya Lakshmi
K S Jaya Lakshmi
RKRamya K
Ramya K
KAKhairunnisa Amreen
Khairunnisa Amreen
Sanket GoelSanket Goel
Sanket Goel
Globally, a contemporary trend is towards the realization of sustainable, eco-friendly, miniaturized, and cost-effective sensors. This work focuses on developing a plug-and-play device using inexpensive and biodegradable UV resin fed 3D printing stereolithography (SLA) to produce miniaturized microfluidic platforms for electrochemical sensing. The device consists of three compartments designed to accommodate the 3-electrodes according to the need. SLA 3D printing technique solves these restrictions, making sensors reliable, repeatable, and durable. For electrochemical detection at the point of need or as a lab-on-chip (LoC) platform with minimal sample volume, this work attempts to construct a flexible as well as non-flexible microelectrode setup. The analytical capability of the platform is examined by quantifying nanomolar levels of dopamine in human body fluids. Chronoamperometry and cyclic voltammetry on surface-treated graphene-poly lactic acid (g-PLA) microelectrodes modified with gold nanoparticles are carried out utilizing a handheld potentiostat. The designed device has a linear range of 0.1 to 120 nM with limit of detection and limit of quantification of 0.083 and 0.27 nM, respectively. Various electrode characterizations, including scanning electron microscopy, energy-dispersive X-ray spectroscopy, and electrochemical impedance spectroscopy are carried out. The developed device is finally tested for real-time analysis on human blood and serum samples.

20 March 2024 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
KRK. Ramya
K. Ramya
KLK. S. Jaya Lakshmi
K. S. Jaya Lakshmi
KAKhairunnisa Amreen
Khairunnisa Amreen
Sanket GoelSanket Goel
Sanket Goel
L-Tyrosine (L-Tyr), a critical amino acid whose aberrant levels impact melanin and dopamine levels in human body while also increasing insulin resistance thereby increasing the risk of type 2. The objective of this study was to detect the amount of L-Tyr in human fluids by tailored electrochemical synthesis of well adhered, homogenous and thin molecularly imprinted polymers (MIPs) by the electro-polymerization of pyrrole on glassy carbon electrode modified functionalized multi-walled carbon nanotubes. The key benefits of this procedure over previous imprinting techniques were the elimination of expensive materials like Au and tedious multi-step synthesis, for L-Tyr detection using a handheld potentiostat. The developed particles were characterized using Fourier Transform Infrared Spectroscopy, Scanning Electron Microscope, Chronoamperometry, and Cyclic Voltammetry. With strong reproducibility and stability, this optimized approach provides a rapid and effective method of preparing and sensing MIPs for the target analyte with a broad linear range of 1 μM to 2000 μM. The Limit of Detection and Limit of Quantification were 0.4 μM and 1.47 μM, respectively. The engineered sensor was validated for quantifying the concentrations of L-Tyr in human blood and serum samples, yielding satisfactory recovery and can be expanded in future to detect analytes simultaneous.

24 October 2024 in IEEE Access
Verified
Journal Article
Open access
MWMrunali D. Wagh
Mrunali D. Wagh
AGAkhilesh Gowrishetty
Akhilesh Gowrishetty
KRK. Ramya
K. Ramya
SSSubhendu Kumar Sahoo
Subhendu Kumar Sahoo
Sanket GoelSanket Goel
Sanket Goel
The accurate detection of triglycerides (fats) in the blood is useful for diagnosing cardiovascular health. This study reports a point-of-care (PoC) electrochemical assay to detect triglycerides using a IoT based smartphone-assisted platform. The assay consists of a flexible polyimide-based microstrip with electrodes composed of polydopamine (PDA)-coated gold nanoparticles (AuNPs) deposited on laser-induced graphene A coating of PDA on the AuNPs helps to anchor lipase enzymes to the electrode, resulting in an enzymatic sensor that is sensitive and specific toward triglycerides. The sensor is connected to a smartphone for data acquisition and monitoring, making it IoT-enabled for PoC applications. Because smartphones are ubiquitous, the approach presented in this paper is more compatible with PoC use than the conventional bulky sensors. The sensor had a linear response to triglyceride concentration, with a limit of detection of 17.89 mg/dL. The apparent Michaelis-Menten constant (K appm ) of 21.6 mg/dL indicates that lipase conjugates strongly with triglyceride, resulting in a limit of quantification of 59.63 mg/dL of triglycerides in a low 2 μL of reference triglyceride solution. The validation of the test using human serum spiked with triglycerides demonstrated a recovery rate of 93.87 % of triglycerides, showing its efficacy when compared to alternative triglyceride sensors, such as metal oxides, conducting polymers, and flow injection that typically have recover rates from 90 % to 110 %. Other common analytes in the serum did not interfere with the sensing. The ability to detect triglycerides using smartphones can lead to improved personalized health monitoring.

18 March 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KRK Ramya
K Ramya
YMYuvraj Maphrio Mao
Yuvraj Maphrio Mao
KAKhairunnisa Amreen
Khairunnisa Amreen
Sanket GoelSanket Goel
Sanket Goel
A plug-and-play, structurally sound electrochemical device is necessary for the simultaneous detection of dopamine and insulin to facilitate real-time health monitoring and optimal diabetes treatment. This research investigates the application of CC/TiO₂ nanofiber-based substrates as a sensitive surface for both. The well-separated and simultaneous detection of dopamine and insulin is enabled by their distinct electrochemical oxidation mechanisms and differential surface interactions on the CC/TiO₂ nanofiber substrate, where the small dopamine molecule undergoes rapid diffusion-controlled electron transfer, while the larger insulin molecule exhibits adsorption-assisted kinetics at higher oxidation potentials. Herein, the response of biosensors to different scan rates and increased analyte concentrations has been analyzed using electrochemical techniques Cyclic Voltammetry (CV) and Chronoamperometry (CA). The results showed a linear increase in current with increasing dopamine and insulin concentrations, confirming high sensitivity and highly efficient electrocatalytic activity. The modified CC/TiO₂ substrates showed superior performance compared to bare carbon cloth, confirming their enhanced detection capabilities. The successful modification of the substrate is confirmed by implementing a detailed characterization that was carried out besides various techniques, such as FTIR, XPS, and morphological studies, as well as results obtained from the electrochemical measurements using K₃Fe(CN)₆ supporting electrolyte. This sensor could be a potential candidate in biomolecule detection and personalized healthcare monitoring due to its biocompatibility, low cost, and high sensitivity.

5 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RKRamya K
Ramya K
BHBhavya H
Bhavya H
NPNayan Prakash
Nayan Prakash
SMSoumyo Mukherji
Soumyo Mukherji
Sanket GoelSanket Goel
Sanket Goel
Accurate detection of L-tyrosine is critical due to its significant role in regulating insulin and glucose metabolism, making it essential for effective diabetes management and related clinical diagnostics. To address this requirement, an optical fiber-based nano molecularly imprinted polymer (MIP) sensor specifically designed for the selective detection of L-tyrosine is developed. This sensor utilizes MIPs synthesized from pyrrole, with L-tyrosine serving as the template molecule. The nano-sized MIPs, characterized by dynamic light scattering (DLS) and scanning electron microscopy (SEM), exhibited a hydrodynamic diameter of 287 nm and uniform morphology. The optical sensing platform is constructed using a U-bent optical fiber with its core modified with 3-Aminopropyl) triethoxysilane (APTES) to enhance its sensitivity by functionalizing the optical fiber surface with amine groups, which improve the adhesion and uniformity of the MIP layer. The MIP layer is applied through an optimized dipping process, achieving the thickness with a 1-hour dipping time, and demonstrated stability for 15 days. With a repeatability of 4 washes. Evaluated using UV-VIS spectrophotometry, the sensor showed high selectivity for L-tyrosine over other analytes, such as dopamine, uric acid, glucose, and creatinine. It exhibited a linear range of 1 μM to 300 μM and a Limit of detection (LOD) of 0.36 μM with strong correlation coefficients (R² = 0.99). This novel in situ MIP-based optical sensor offers a robust, sensitive, and specific tool for clinical diagnostics, food safety monitoring, and environmental analysis. The developed device is finally tested on a portable μSens optical device as well as real-time analysis on human blood and serum samples.