29 March 2025 in Alexandria Engineering Journal
4 October 2022 in Talanta Open
A severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a cause of worldwide Coronavirus 2019 (COVID-19) disease pandemic. It is thus important to develop ultra-sensitive, rapid and easy-to-use methods for the identification of COVID-19 infected patients. Herein, an alternative electrochemical immunosensor based on poly(pyrrolepropionic acid) (pPPA) modified graphene screen-printed electrode (GSPE) was proposed for rapid COVID-19 detection. The method was based on a competitive enzyme immunoassay process utilizing horseradish peroxidase (HRP)-conjugated SARS-CoV-2 as a reporter binding molecule to compete binding with antibody against the SARS-CoV-2 receptor binding domain (SARS-CoV-2 RBD) protein. This strategy enhanced the current signal via the enzymatic reaction of HRP-conjugated SARS-CoV-2 RBD antibody on the electrode surface. The modification, immobilization, blocking, and detection processes were optimized and evaluated by amperometry. The quantitative analysis of SARS-CoV-2 was conducted based on competitive enzyme immunoassay with amperometric detection using a 3D-printed portable potentiostat for point-of-care COVID-19 diagnosis. The current measurements at -0.2 V yielded a calibration curve with a linear range of 0.01–1500 ng mL−1 (r2 = 0.983), a low detection limit of 2 pg mL−1 and a low quantification limit of 10 pg mL−1. In addition, the analyzed results of practical samples using the developed method were successfully verified with ELISA and RT-PCR. Therefore, the proposed portable electrochemical immunosensor is highly sensitive, rapid, and reliable. Thus, it is an alternative ready-to-use sensor for COVID-19 point-of-care diagnosis.
1 November 2023 in Journal of the Electrochemical Society
This study describes the development of a novel, ultrasensitive, and selective electrochemical sensor to determine imiquimod (IMQ) using a screen-printed carbon electrode (SPCE) modified with MXene (Ti3C2Tx), graphene nanoplatelets, and ionic liquid (Ti3C2Tx/GNPs/IL). This work reveals the synergistic effect of Ti3C2Tx, GNPs, and IL, where Ti3C2Tx and GNPs provide a large active electrode area and excellent electron transport, and IL exhibits remarkable electrocatalytic behavior. Benefiting from the excellent electrochemical properties of the composite, the developed sensing platform enabled superior electrochemical performance for IMQ in the broad linear range of 0.071–92.0 μM (R2 = 0.999) with a limit of detection (LOD) of 0.487 nM and a detection sensitivity of 7.558 μA μM−1 cm−2. Meanwhile, the sensor has shown good repeatability, reproducibility, stability, and anti-interference ability and has been subsequently used to detect IMQ in cream formulations with satisfactory recoveries (98.33%–99.34%) and lower relative standard deviations (<3%). The findings indicate that the newly developed sensor can contribute to the development of a portable, robust, and high-performance sensing strategy for multidisciplinary targets.
25 April 2025 in Microchemical Journal
19 August 2026 in ACS Omega
Citrullinated histone H3 (CitH3) is an emerging biomarker for early sepsis diagnosis. However, its detection based on standard enzyme-linked immunosorbent assay (ELISA) suffers from long analysis time (4–5 h), expensive instruments, and the need for skilled operators, necessitating the development of alternative detection platforms. Herein, a portable electrochemical immunosensor for CitH3 determination was developed using a screen-printed graphene electrode coupled with a custom-designed potentiostat. CitH3 was detected via a sandwich immunoassay employing horseradish peroxidase–conjugated antibody and amperometric measurement in the presence of hydroquinone and hydrogen peroxide. Key fabrication and detection parameters were systematically optimized to achieve high analytical performance. Under optimal conditions, the immunosensor exhibited a linear detection range of 0.1–1000 ng mL–1 with a detection limit of 42.83 pg mL–1 and a quantification limit of 100.89 pg mL–1, enabling the discrimination between sepsis and nonsepsis conditions. Additionally, the developed method provided a lower detection limit and shorter processing time (2 h) compared with ELISA. It also demonstrated high selectivity against common serum interferents, satisfactory accuracy (recovery = 89.49–106.11%), and good repeatability (relative standard deviation < 10%). Analysis of clinical serum samples (n = 50) showed a high correlation coefficient with ELISA (r = 0.9861), and Bland–Altman analysis confirmed their good agreement. Furthermore, the assay diagnostic performance demonstrated 100% specificity with high sensitivity values of 90.01% and 81.25% for sepsis and severe sepsis cases, respectively. These results suggested the potential of the proposed portable electrochemical immunosensor as a practical tool for sepsis diagnosis.
27 October 2026 in ACS Omega
In this study, we introduce novel multifunctional biomaterial inks for extrusion-based 3D bioprinting to create scaffolds for potential tissue engineering. This study focuses on developing composite materials by incorporating alkyl ketene dimer (AKD)-modified graphene nanoplatelets (GP) into polylactide (PLA) using a solvent casting technique. GP was synthesized via electrolytic exfoliation in an aqueous poly(sodium 4-styrenesulfonate) solution and subsequently modified with AKD by ball milling to enhance dispersion and PLA compatibility. Physical and chemical characterization confirmed the successful synthesis and structural properties of the AKD-modified GP. PLA-GPD20 films containing 20 wt % AKD-modified GP exhibited significantly improved elongation at break and maintained tensile strength comparable to neat PLA. All biomaterial composite films exhibited high stiffness, as evidenced by glass transition temperatures above room temperature, and electrical conductivity in the semiconductor range. The results highlight the significant positive impact of AKD on the physical and electrical properties, as well as the printability, of the composites. The printability performance potential was evaluated using 10 wt % PLA-GPD20 biomaterial inks to generate scaffolds with different patterns. The mechanical testing of the printed scaffolds revealed that the tensile strength and modulus increased with the incorporation of GPD20. The printing orientation is an effective parameter for tuning the balance between stiffness and ductility; scaffolds printed at 90° exhibited higher Young’s modulus but lower elongation at yield and tensile strength than those printed at 45°. Furthermore, incorporating AKD into GP/PLA composites improved hydrophobicity. The results suggest that AKD-modified graphene composites hold substantial promise for the development of advanced multifunctional materials for tissue engineering applications.