Model-free predictive current control (MFPCC) has been widely used in voltage source inverters (VSIs). The output current performance of look-up-table-based MFPCC is affected by the number of the applied voltage vectors (VVs), the current gradient updating and the sampling disturbance. To improve the current performance, a novel modulated MFPCC is proposed for VSI, while real-time current gradient updating and sampling disturbance suppression can be achieved. First, three basic VVs are picked, whose duration time are computed according to the current gradients. Second, an advanced current gradient updating method is presented by establishing the equations of different current gradients under different VVs. Furthermore, the sampling disturbance effect on MFPCC is analyzed and an extended state observer is designed to suppress such effect. Simulation model and experimental platform of the VSI system are structured to verify the preponderance of the proposed MFPCC in reducing the total harmonic distortion of output current.
22 May 2023 in IEEE Transactions on Industrial Electronics
Model-free predictive current control (MFPCC) methods based on look-up tables (LUTs) have been widely applied in voltage source inverters (VSIs) due to their simple implementation and excellent robustness. However, the performance of the VSIs is affected by the voltage vector used, accuracy of current gradients, and sampling noise. In order to improve these, a new double-vector MFPCC method is proposed in this article. First, a synthetic voltage vector composed of double vectors is applied in each control period to reduce current ripples, where the durations of the double vectors are calculated using predicted current gradients. Next, an extended LUT is designed by using the current gradients of the applied synthetic voltage vectors to update all current gradients of eight basic voltage vectors, so as to increase the accuracy of current gradients. Then, the effect of the sampling noise on MFPCC is analyzed in detail and suppressed by a sliding mode observer for the VSIs. Finally, simulation and experimental results have verified the effectiveness of the proposed method.
13 February 2020 in IEEE Transactions on Industrial Electronics
Online insulation monitoring techniques for power transformers have been widely studied. However, challenges rise when applied to the converter-connected transformers which are operated under high electrical stress conditions. This paper proposes a non-intrusive leakage-current-based insulation monitoring strategy for converter transformers, using inherent characteristic harmonics in voltage source converter system. Analytic relation between common-mode and differential-mode harmonics and insulation capacitances is firstly presented. Then, a combined strategy is proposed based on the differential measurement of leakage current, which enables online prognosis of not only overall ageing degree but also ageing localization of the phase-to-ground insulation. Experiments are conducted on a 15-kVA transformer driven by an industrial inverter. The proposed combined strategy shows robust performance over effective characteristic frequency spectrums. Several considerations for field implementation are further discussed. The major features of the proposed strategy are: 1) easy implementation and non-intrusive measurement; 2) little impact on system operation and immunity to system interferences; 3) lower requirements of data processing.
8 December 2023 in IEEE Transactions on Industrial Electronics
The parametric uncertainties have a great effect on the output voltage of grid-forming inverters when they are operated under conventional modulated model predictive control (MPC). To address this known issue, a novel modulated model-free predictive control (MFPC) is proposed in this article. First, a new look-up table (LUT) formed by capacitor voltage differences and inductor current differences of LC -filter is designed for voltage-current predictions. Then, the state-space equations of different voltage vectors are established and reconstructed to update each voltage-current difference in the LUT per control period. Next, the duration of each voltage vector and the voltage prediction are calculated based on the updated voltage differences, so as to remove the impact of parameter variation on duration calculation and prediction calculation, enabling their robustness. Finally, the practicality of the proposed approach is demonstrated experimentally under both ideal and mismatched parameters. In comparison with conventional modulated MPC, the proposed modulated MFPC not only achieves comparable voltage performance, but also exhibits greater robustness.
22 March 2022 in IEEE Transactions on Industry Applications
Online stator winding insulation monitoring is becoming an important topic in recent years and many online monitoring methods have been proposed. In these methods, the online common-mode impedance spectrum method can monitor the condition of the ground-to-wall insulation accurately based on the switching harmonics and no additional signal injection equipment is needed. However, the existing method has the limit that it can only detect the overall insulation aging condition. The coils at the line end are subjected to a higher voltage and their insulation degrades faster than the part closer to the neutral end. It is a common practice to change connections to reverse the line and neutral ends to extend the insulation life for Y-connection stator winding machines. In this condition, the existing method would give false alarm because it estimates the severity of aging at different positions of the winding as a whole unit. In this article, the proposed method monitors the parallel capacitance in the frequency range both below and above the resonance frequency. Using multifrequency information, the proposed method can distinguish the insulation aging at different locations, which improves the performance of this monitoring method. The offline and online experimental results both validate the proposed method.
1 July 2021 in IEEE Transactions on Industry Applications
The winding impedance spectrum method becomes popular in online stator insulation monitoring in recent years. It can detect the insulation ageing condition and give alarm before catastrophic failure happens. However, the theoretical explanation of this method is not sufficient and the relationship between impedance spectrum and insulation ageing is not clear. In addition, the existing methods need additional signal injection equipment, which is intrusive and difficult to be applied in industrial applications. Therefore, this article develops a noninvasive interturn insulation condition monitoring method based on the common-mode impedance spectrum in inverter-fed machines. By building a broadband stator winding insulation model, the relationship between the interturn insulation ageing and the impedance spectrum is studied and the high frequency parallel capacitance is first proposed as an indicator for the interturn ageing. The offline test validate the effectiveness of the proposed method and the online test shows the potential of this method for noninvasive condition monitoring in inverter-fed machines. Future work is planned to further improve the online performance of the proposed method.