Morten Olavsbraten

Morten Olavsbraten

Auto-generated profile, based on publicly available information

Morten Olavsbraten

Department of Electronics and Telecommunications, Norwegian University of Science and Technology, Trondheim, Norway

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2017 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
MOMorten Olavsbraten
Morten Olavsbraten
DGDragan Gecan
Dragan Gecan
This letter develops a new technique that significantly reduces the bandwidth requirements of the drain supply for an envelope tracked power amplifier (ET-PA). The achieved bandwidth reduction is clearly quantified, and requires almost no processing. The technique is based on developing a drain tracking voltage function that follows the power of the envelope. The use of pure power envelope tracking (PET) results in significant lower bandwidth, with some reduction of efficiency, compared with ET. A second-order PET extension doubles the PET bandwidth and achieves almost the same efficiency as ET. The validity of the PET and the second-order PET is confirmed with measurements on a 2-GHz 10-W GaN PA. The measured results show a bandwidth reduction relative to pure ET of a factor 3 to 8 for PET and 1.4 to 3.8 for the second-order PET. The corresponding efficiencies are 53% and 61.8%, compared with 63% for ET. The linearity is slightly better for PET. All measured with a 16-QAM signal and an average output power of 35.6 dBm.

16 November 2018 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
MDMaxwell Robert Duffy
Maxwell Robert Duffy
GLGregor Lasser
Gregor Lasser
MOMorten Olavsbraten
Morten Olavsbraten
EBEric Berry
Eric Berry
ZPZoya Popovic
Zoya Popovic
The goal of the work presented in this paper is to demonstrate an efficient method of amplifying multiple concurrent signals over a large bandwidth using a supply modulation approach. A single-stage octave bandwidth (2-4 GHz) power amplifier (PA) with greater than 10-W output power and drain efficiency ranging from 48%-60% is presented. The amplifier is tested with several reduced-bandwidth supply modulation trajectories that are constructed as an even-termed power series of a 10-MHz LTE signal envelope. A greater than 30% point increase in eta D is achieved while maintaining less than -45-dB ACPR with digital predistortion (DPD). Two 10-MHz LTE signals with 800-MHz spacing are then amplified using a similar bandwidth-reduction technique. A greater than 20% point increase in eta D is seen with an improvement in linearity through the use of multidimensional DPD. The method presented here can be extended to more than two concurrent signals of arbitrary spacing for a PA with large RF bandwidth.

1 April 2017
Verified
Conference Paper
Closed access
GLGregor Lasser
Gregor Lasser
MDMaxwell Duffy
Maxwell Duffy
MOMorten Olavsbraten
Morten Olavsbraten
ZPZoya Popovic
Zoya Popovic
In this paper we study static and dynamic gate biasing of a two-stage X-band MMIC GaN PA. The PA is first characterized under different bias conditions using large-signal static measurements, and the determined conditions are then applied to dynamic measurements with a 20 MHz noise power ratio (NPR) test signal. Biasing the gates of the two stages independently allows simultaneous reduction of amplitude and phase distortion. AM/AM, AM/PM and PAE measurements are obtained for three different static scenarios. Consistent results from static and dynamic tests are obtained showing NPR values exceeding 31 dB. Adding predistortion alters the efficiency of the investigated static biases by more than 4 % points.

1 July 2024 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
CNConnor Nogales
Connor Nogales
PFPaul Flaten
Paul Flaten
MOMorten Olavsbråten
Morten Olavsbråten
ZPZoya Popović
Zoya Popović
GLGregor Lasser
Gregor Lasser
The effect of source (gate-side) and load (drain-side) impedance match on the linearity and efficiency of an envelope-tracked power amplifier (PA) is investigated. Conventionally designed GaN PAs exhibit an increasing gain magnitude and phase with increasing drain supply voltage. When this supply voltage is dynamically modulated in discrete levels for efficiency enhancement, the changing gain distorts the output signal and degrades linearity. The dependency of the PA gain on drain supply voltage can be minimized, however, through proper selection of the source and load impedances. This is illustrated through source/load pull simulations of a $8\times 100$ $\mu$ m GaN HEMT, which reveal impedances that result in low gain magnitude and phase variation. Three PA design (matching) cases are then chosen and their performances are evaluated with an ideal dynamically changing supply. For the comparison, envelope simulations with a 67.5-MHz 64-QAM signal are performed and show that dynamic supply modulation of the mismatched PA design improves linearity and efficiency over a conventional PA designed for maximum efficiency/gain. The simulation results are validated through measurements of a deliberately mismatched, 6.2–12.6-GHz, 5-W GaN MMIC PA envelope-tracked with a GaN MMIC four-level supply modulator. Compared with a static supply, the dynamic results show improvement in average efficiency and a small penalty in linearity without using DPD.

1 June 2017
Verified
Conference Paper
Closed access
MDMaxwell R. Duffy
Maxwell R. Duffy
GLGregor Lasser
Gregor Lasser
JVJason Vance
Jason Vance
MOMorten Olavsbraten
Morten Olavsbraten
TBTaylor Barton
Taylor Barton
ZPZoya Popovic
Zoya Popovic
This paper introduces bandwidth reduction methods for supply modulation when multiple broadband signals spread over a wide RF bandwidth are simultaneously amplified by a high-efficiency PA. The PA is a GaN on SiC MMIC in the Qorvo 150-nm process with two stages and power combining at the output. With a CW signal at 9.8 GHz, the peak power is 8W with a peak efficiency of 56% and a saturated gain greater than 23 dB. Three 16QAM signals with bandwidths of 1, 2 and 5 MHz, separated by 70 and 130 MHz and centered around 9.8 GHz have a combined envelope bandwidth of > 800 MHz and a PAR around 9.5 dB, which is too large for an efficient envelope modulator. We show that the tracking bandwidth can be significantly reduced when the envelopes of the individual signals are summed at baseband. Measured results show 42.4% PAE and 18.8% worst-case EVM when tracking is used, compared to 29.7% PAE and 14.4% EVM for a fixed supply with no linearization.

1 November 2016
Verified
Conference Paper
Closed access
DGDragan Gecan
Dragan Gecan
MOMorten Olavsbraten
Morten Olavsbraten
KGKarl Martin Gjertsen
Karl Martin Gjertsen
This paper presents investigation on how linearity performance changes for different gate bias voltages for the ET and AET 10 W GaN HEMT power amplifier. It is shown that by selecting optimal gate bias voltage, AM-AM and AM-PM transfer characteristics can be more constant for a given power dynamic range which results with better linearity. Moreover, the efficiency can stay preserved. Benefit of selecting optimal bias point is possible simplification of the digital predistorter for ET PA linearization and achievement of maximal linearization capabilities out of AET PA.