Margit W. Frederiksen

Margit W. Frederiksen

Auto-generated profile, based on publicly available information

Margit W. Frederiksen

National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Waste Management
Verified
Journal Article
Open access
AMAnne Mette Madsen
Anne Mette Madsen
MFMargit W. Frederiksen
Margit W. Frederiksen
MBMette Bjerregaard
Mette Bjerregaard
KTKira Tendal
Kira Tendal
Waste collection is associated with various health symptoms. The aims of this study were to obtain knowledge about exposure to bacteria, fungi, and endotoxin during waste collection, and to study whether it is possible to reduce the exposures and the total inflammatory potential (TIP) of those exposures through simple interventions. The study was performed with an initial baseline exposure assessment, a second assessment with intervention workers only, and a third with intervention and reference workers. The waste collection workers were exposed to 7.8 × 103 cfu bacteria/m3, 1.4 × 104 cfu fungi/m3, and 92 endotoxin units/m3 (geometric mean values). The potential exposures in the truck cabs were up to 23 times higher than outdoor reference concentrations. For the intervention trucks and workers, airborne fungi in the truck cab were reduced; fungi, bacteria, and yeasts on the steering wheels were reduced; and the concentration of fungi on the workers' hands was reduced. Exposures were typically highest during collection of mixed household waste, in the summer, and for collection using trucks with low loading height. The TIP was highest for the reference group sampling mixed household waste, using trucks with low loading height, in the summer. Endotoxin, bacteria, and fungi contributed to the TIP of 42 personal exposure assessments. CONCLUSION: Motivating workers to reduce exposure through simple interventions improved hand and truck cab hygiene, but only slightly reduced personal exposure to airborne bioaerosols. Exposure can be reduced by only using trucks with high loading height.

31 March 2023 in UCL Open Environment
Verified
Preprint
Open access
PDF file
AMAnne Mette Madsen
Anne Mette Madsen
SMSaloomeh Moslehi-Jenabian
Saloomeh Moslehi-Jenabian
MFMika Frankel
Mika Frankel
JWJohn Kerr White
John Kerr White
MFMargit W. Frederiksen
Margit W. Frederiksen
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in five homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis and Paracoccus yeei. The concentrations of Gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila and B. pumilus were associated positively with relative humidity (RH), and concentrations of K. rhizophila were associated negatively with temperature and air change rate (ACR). Micrococcus flavus concentrations were associated negatively with ACR. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, ACR and RH.

1 January 2014 in Science of The Total Environment
Verified
Journal Article
Open access
AMAnne Mette Madsen
Anne Mette Madsen
KTKira Tendal
Kira Tendal
MFMargit W. Frederiksen
Margit W. Frederiksen
Indoor handling of large amounts of plant materials occurs in different occupational settings including greenhouses and causes exposure to bioaerosols. The bioaerosol components fungi, β-glucan, bacteria and endotoxin are involved in different airway symptoms and health effects can be dose-dependent. Therefore, there is a persistent need to reduce exposure. The aims of this study were to identify tasks causing exposure and to evaluate preventive measures aimed at reducing exposure of greenhouse workers to bioaerosols, and to study factors affecting the exposure. We have focused on different exposure scenarios; one with high short-term exposure found during clearing of old cucumber plants; the other with long-term, mid-level exposure found during tomato picking, leaf nipping, stringing up tomato plants, and packaging of cucumbers. Clearing of non-dried cucumber plants compared with clearing of dried cucumber plants significantly reduced the exposure to dust, endotoxin, bacteria, fungal spores and β-glucan. More endotoxin and fungi are emitted and more of the emitted particles were of respirable size if the leaves were dried. Along the cucumber packaging line, exposure levels were highly specific to each personal subtask. The subtask 'unloading of cucumbers' was the source of exposure making task ventilation or shielding of the process a possibility. Elimination of leaf debris on the floor reduced the exposure to fungi significantly. However, leaf debris on the floor did not contribute significantly to the exposure to dust, endotoxin and bacteria. Furthermore, to eliminate leaf debris, it had to be cleared away and this was associated with a higher exposure to dust and endotoxin. The age of the plants affected the exposure level to bioaerosols with higher exposures from old plants. In conclusion, different tasks and subtasks cause very different exposure levels. It is possible to reduce exposure by identifying subtasks causing the exposure and by modifying work processes, e.g., not drying out of plants.

10 June 2023 in Annals of Work Exposures and Health
Verified
Journal Article
Open access
PDF file
PRPil Uthaug Rasmussen
Pil Uthaug Rasmussen
KUKatrine Uhrbrand
Katrine Uhrbrand
MFMargit W Frederiksen
Margit W Frederiksen
AMAnne Mette Madsen
Anne Mette Madsen
Indoor microbial exposure may cause negative health effects. Only little is known about the occupational microbial exposure in nursing homes and the factors that influence the exposure. The exposure in nursing homes may be increased due to close contact with elderly persons who may carry infectious or antimicrobial-resistant microorganisms and due to handling of laundry, such as used clothing and bed linen. We investigated the microbial exposure in 5 nursing homes in Denmark, by use of personal bioaerosol samples from different groups of staff members taken during a typical working day, stationary bioaerosol measurements taken during various work tasks, sedimented dust samples, environmental surface swabs, and swabs from staff members’ hands. From the samples, we explored bacterial and fungal concentrations and species composition, endotoxin levels, and antimicrobial resistance in Aspergillus fumigatus isolates. Microbial concentrations from personal exposure samples differed among professions, and geometric means (GM) were 2,159 cfu/m3 (84 to 1.5 × 105) for bacteria incubated on nutrient agar, 1,745 cfu/m3 (82 to 2.0 × 104) for bacteria cultivated on a Staphylococcus selective agar, and 16 cfu/m3 air for potential pathogenic fungi incubated at 37 °C (below detection limit to 257). Bacterial exposures were elevated during bed making. On surfaces, the highest bacterial concentrations were found on bed railings. The majority of bacterial species found were related to the human skin microflora, such as different Staphylococcus and Corynebacterium species. Endotoxin levels ranged from 0.02 to 59.0 EU/m3, with a GM of 1.5 EU/m3. Of 40 tested A. fumigatus isolates, we found one multiresistant isolate, which was resistant towards both itraconazole and voriconazole, and one isolate resistant towards amphotericin B. In conclusion, we give an overview of the general microbial exposure in nursing homes and show that microbial exposures are higher for staff with more care and nursing tasks compared with administrative staff.

28 May 2025 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Open access
AMAnne Mette Madsen
Anne Mette Madsen
MFMargit W. Frederiksen
Margit W. Frederiksen
HÁHjördís Birna Árnadóttir
Hjördís Birna Árnadóttir
Occupational exposure to airborne fungi in indoor environments may pose respiratory health risks. This study aimed to characterize exposure to fungi, bacteria, and endotoxin in a historical museum where the staff reported airway symptoms. Air samples were collected during three separate workdays using personal and stationary samplers. Fungi and bacteria were quantified and identified using MALDI-TOF MS, and the total inflammatory potential was measured through Reactive Oxygen Species (ROS) production in a human cell line. The geometric mean of staff exposure was 5.9 × 103 CFU/m3 fungi, 1.8 × 103 CFU/m3 bacteria, and 7.93 EU/m3 endotoxin. Staff reported symptoms of the airways, with immediate symptoms upon entering two departments, which exhibited elevated fungal concentrations compared to other departments. The most prevalent fungal species were Aspergillus conicus, A. domesticus, A. pseudoglaucus, A. pseudogracilis, and Cladosporium spp. Concentrations of bacteria were highest when staff were present and without dominance by any particular species. Staff exposure and stationary samples induced ROS production in a cell line, which correlated with concentrations of fungi, bacteria, and endotoxin. Fungi were detected on the museum artifacts, and concentrations of fungi and bacteria increased during handling of the artifacts. In conclusion, staff in the two departments where airway symptoms were reported were exposed to 2 × 104 to 7 × 104 CFU/m3 of fungi, primarily Aspergillus spp. and Cladosporium. spp. This exposure constituted both xerophilic species and species commonly found in water-damaged buildings, and they seemed to have developed on artifacts. These findings underscore the importance of developing preventive strategies to protect the health of museum staff. Moreover, it highlights the challenge of managing fungi adapted to varying humidity conditions.

22 February 2023 in UCL Open Environment Preprint
Verified
Preprint
Open access
AMAnne Mette Madsen
Anne Mette Madsen
SMSaloomeh Moslehi-Jenabian
Saloomeh Moslehi-Jenabian
MFMika Frankel
Mika Frankel
JWJohn Kerr White
John Kerr White
MFMargit W. Frederiksen
Margit W. Frederiksen
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in 5 homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis, and Paracoccus yeei. The concentrations of gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila, and B. pumilus were associated positively with relative humidity, and concentrations of K. rhizophila were associated negatively with temperature and air change rate. Micrococcus flavus concentrations were associated negatively with air change rate. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, air change rate, and relative humidity.