Till Moritz Eßinger

Till Moritz Eßinger

Auto-generated profile, based on publicly available information

Till Moritz Eßinger

Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMartin Koch
Martin Koch
TET. M. Eßinger
T. M. Eßinger
HMH. Maier
H. Maier
JSJ. H. Sim
J. H. Sim
LRL. Ren
L. Ren
MBM. Bornitz
M. Bornitz
Human temporal bone specimens are used in experiments measuring the sound transfer of the middle ear, which is the standard method used in the development of active and passive middle ear implants. Statistical analyses of these experiments usually require that the TB samples are representative of the population of non-pathological middle ears. Specifically, this means that the specimens must be mechanically well-characterized. We present an in-depth statistical analysis of 478 data sets of middle ear transfer functions (METFs) from different laboratories. The data sets are preprocessed and various contributions to the variance of the data are evaluated. We then derive a statistical range as a reference against which individual METF measurements may be validated. The range is calculated as the two-sided 95% tolerance interval at audiological frequencies. In addition, the mean and 95% confidence interval of the mean are given as references for assessing the validity of a sample group. Finally, we provide a suggested procedure for measuring METFs using the methods described herein.

1 October 2016 in Hearing Research
Verified
Journal Article
Closed access
MKMartin Koch
Martin Koch
TETill Moritz Eßinger
Till Moritz Eßinger
TSThomas Stoppe
Thomas Stoppe
NLNikoloz Lasurashvili
Nikoloz Lasurashvili
MBMatthias Bornitz
Matthias Bornitz
TZThomas Zahnert
Thomas Zahnert

7 August 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MKMartin Koch
Martin Koch
TETill Moritz Eßinger
Till Moritz Eßinger
MBMatthias Bornitz
Matthias Bornitz
TZThomas Zahnert
Thomas Zahnert
Implantable assembly components that are biocompatible and highly miniaturized are an important objective for hearing aid development. We introduce a mechanical transducer, which could be suitable as part of a prospective fully-implantable hearing aid. The transducer comprises a sensor and an actuator unit in one housing, located in the joint gap between the middle ear ossicles, the incus and stapes. The setup offers the advantage of a minimally invasive and reversible surgical solution. However, feedback between actuator and sensor due to mechanical coupling limits the available stable gain. We show that the system can be stabilized by digital control algorithms. The transducer is tested both in a finite elements method simulation of the middle ear and a physical model of a human middle ear. First, we characterize the sensor and actuator elements separately. Then, the maximum stable gain (MSG) of the whole transducer is experimentally determined in the middle ear model. With digital feedback control (using a least mean squares algorithm) in place, the total signal gain is greater than 30 dB for frequencies of 1 kHz and above. This shows the potential of the transducer as a high frequency hearing aid.

1 July 2019 in Hearing Research
Verified
Journal Article
Closed access
TETill Moritz Eßinger
Till Moritz Eßinger
MKMartin Koch
Martin Koch
MBMatthias Bornitz
Matthias Bornitz
NLNikoloz Lasurashvili
Nikoloz Lasurashvili
MNMarcus Neudert
Marcus Neudert
TZThomas Zahnert
Thomas Zahnert

1 July 2019 in Hearing Research
Verified
Journal Article
Closed access
MKMartin Koch
Martin Koch
TETill Moritz Eßinger
Till Moritz Eßinger
MAMartin Angerer
Martin Angerer
TSThomas Stoppe
Thomas Stoppe
MBMatthias Bornitz
Matthias Bornitz
TZThomas Zahnert
Thomas Zahnert

1 July 2015
Verified
Conference Paper
Closed access
TETill Moritz Essinger
Till Moritz Essinger
RHRudiger Hoffmann
Rudiger Hoffmann
We examine a 10:1 scale model of a recently proposed type of integrated sensor-actuator system to be used as part of a middle-ear hearing implant, and show that this inherently unstable system can be controlled by conventional methods of digital feedback suppression. Sensor and actuator of the model are mechanically coupled by a free-floating hard metal frame about 30 mm in length, corresponding to 3 mm original scale. Due to the direct mechanical coupling, the resulting electroacoustic system exhibits strong feedback and high-frequency oscillation will occur even at small gain. We show that the feedback of this system can be successfully controlled by delaying the signal in the forward path and then applying adaptive and active filtering. Through the use of a least-mean-square adaptive filter combined with active digital filtering, an increase in maximum stable gain (MSG) of up to 43 dB and a functional gain of up to 35 dB (maximum) and 24.7 dB (mean) are achieved.