14 February 2019 in IEEE Transactions on Power Electronics
Threshold-voltage mismatch among paralleled dice in power module leads to unbalanced turn-on peak currents and switching energies, degrading reliability. A passive method employing inversely coupled air-core inductors reduces current unbalance. An integrated design of the coupled inductors is required to facilitate their practical use in power module. Layout to achieve inverse coupling, high coupling coefficient, and low voltage stress, as well as magnetic materials suitable for operation at tens of MHz, and high current rating of tens of Amperes with small magnetic core are the challenges for its implementation. A module with integrated coupled inductors that achieve inverse coupling by utilizing the copper trace of the substrate and bond wires, size comparable to the silicon carbide (SiC) die, coupling coefficient higher than 0.98, tens of nH operating at tens of MHz, and current rating of tens of Amperes was designed, fabricated, and validated in this work. The designed coupled inductors are compatible with existing packaging technology for module fabrication. Compared with the baseline module following commercial practice, the module with integrated coupled inductors reduces current unbalance from 36% to 6.4% and turn-on-energy difference from 28% to 2.6% while maintaining the same total switching energy and negligible change of voltage stress.
16 June 2017 in IEEE Transactions on Industrial Electronics
Cross-turn-on happens in a phase leg comprising high-side switch(es) and low-side switch(es) when the turn-on of one switch inadvertently triggers the channel current to flow in the off-switch. The terminal current does not reflect the internal channel current because of the numerous parasitic inductances from the package. Detection of the cross-turn-on in a power module is difficult since the dice are usually encapsulated and the channel currents are hard to measure. A nonintrusive method to identify the cross-turn-on based on the changing ringing current is introduced in this paper. The detection method is analyzed theoretically and validated by experiments using a 1.2-kV SiC module. The negative drive voltage and gate resistance for safe operation can be determined by the detection method.