14 February 2019 in IEEE Transactions on Power Electronics
Threshold-voltage mismatch among paralleled dice in power module leads to unbalanced turn-on peak currents and switching energies, degrading reliability. A passive method employing inversely coupled air-core inductors reduces current unbalance. An integrated design of the coupled inductors is required to facilitate their practical use in power module. Layout to achieve inverse coupling, high coupling coefficient, and low voltage stress, as well as magnetic materials suitable for operation at tens of MHz, and high current rating of tens of Amperes with small magnetic core are the challenges for its implementation. A module with integrated coupled inductors that achieve inverse coupling by utilizing the copper trace of the substrate and bond wires, size comparable to the silicon carbide (SiC) die, coupling coefficient higher than 0.98, tens of nH operating at tens of MHz, and current rating of tens of Amperes was designed, fabricated, and validated in this work. The designed coupled inductors are compatible with existing packaging technology for module fabrication. Compared with the baseline module following commercial practice, the module with integrated coupled inductors reduces current unbalance from 36% to 6.4% and turn-on-energy difference from 28% to 2.6% while maintaining the same total switching energy and negligible change of voltage stress.
16 January 2017 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Silicon carbide dice are often paralleled to realize power modules with high current rating. Owing to the large network of interconnect (parasitic) impedances, terminal waveforms could appear benign while the dice experience detrimental fault currents generated by spurious cross-turn-on. This paper will quantify the nonuniform distributions of current stress and switching energy among the dice, as well as the penalty caused by cross-turn-on, versus number of dice, gate resistance, input voltage, and switching current. A reliable model for the package is essential. This is demonstrated for a commercial power module with 16 dice, 124 layout inductances, and the companion parallel resistances extracted from the finite-element simulation. Modeling process to avoid convergence problem is developed and verified by the experimental results. For a module tested at 800 V/300 A and carrying six paralleled dice per switch, the cross-turn-on induced current spikes simulated without and with package model differ by as much as 11.75 times. Cross-turn-on increases the high-side switching energy and the total switching energy of the module by 44% and 20%, respectively. One-die, two-die, four-die, and six-die modules are constructed based on the asymmetrical layout to explore how the number of dice influences cross-turn-on and switching energy. Peak cross-turn-on current and total switching energy of the module increase with the number of dice. The peak cross-turn-on current and switching energy of the six-die module are 134% and 36% higher than those of the one-die module, respectively. Severity of cross-turn-on soars as the number of dice increases.
30 March 2021 in IEEE Transactions on Industrial Electronics
To address the hard-switching issue of conventional buck converter and high voltage/current stress issue of soft-switched converter like resonant cross-commutated buck converter, a new soft-switched dc-dc topology with two-phase operation is proposed in this work. The ac current generated from the floating half-bridge of one phase is injected into the switching node of another phase to realize zero-voltage switching for all MOSFETs and zero-current switching for the low-side MOSFETs. This method is named as active cross-commutation (Acc). The benefits of AccBuck converter include soft switching, low voltage stress of low-side switches, low current stress for all switches, and fixed switching frequency. The operation principles with and without parasitic output capacitance (Coss) are analyzed by using the state-plane method. Clamped diodes are added to reduce the Coss-related ringing. The analytical formula of voltage gain is derived, which is related to the duty ratio, Coss, inductance, load current, and switching frequency. A prototype was fabricated to demonstrate the proposed converter. During the fixed-duty-ratio operation, the converter achieves 97.8% peak efficiency and 1410 W/in3 power density at 50 A output current, 54 V input, and 9 V output. The calculated load line and regulation capability are also verified experimentally.
1 October 2016 in International Symposium on Microelectronics
Silicon carbide (SiC) dice are often paralleled to realize power modules with high-current rating. Owing to the large network of interconnect (parasitic) impedances, terminal waveforms could appear benign while the dice experience detrimental fault currents generated by spurious cross-turn-on. This paper will quantify the non-uniform distribution of current stress and switching energy among the dice, as well as the penalty caused by cross-turn-on, versus layout symmetry, number of dice, gate resistance, input voltage, and load current. Cross-turn-on currents inside a module increase the high-side switching energy and total switching energy by 44% and 20%, respectively, at 800 V / 300 A. Peak cross-turn-on current of the symmetrical module is only 16% of that of asymmetrical module at nominal condition. Symmetrical layout greatly decreases the cross-turn-on currents without increasing the total switching energy. Four modules are constructed based on the asymmetrical layout to explore how number of dice influences cross-turn-on and switching energy. Peak cross-turn-on current and switching energy of the six-die module are 134% and 36% higher than those of the one-die module, respectively. Severity of cross-turn-on soars as number of dice increases.