Tyll Jandewerth

Tyll Jandewerth

Auto-generated profile, based on publicly available information

Tyll Jandewerth

Department of Ophthalmology Goethe‐University Frankfurt Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2024 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Open access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
TJTyll Jandewerth
Tyll Jandewerth
JBJulian Bucur
Julian Bucur
TKThomas Kohnen
Thomas Kohnen
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
Background: To assess changes in ocular biometry of the phakic eye after pars‐plana‐vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.Methods: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000‐centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept‐source optical coherence tomography‐based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.Results: The mean age was 62.1 ± 8.3 years (range: 37–85). After PPV with SO fill, there was an increase in Kmean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to −0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.Conclusions: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.

1 November 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
TJTyll Jandewerth
Tyll Jandewerth
JWJoukje C. Wanten
Joukje C. Wanten
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
MSMariam Sobhi
Mariam Sobhi
TKThomas Kohnen
Thomas Kohnen
Purpose: To assess the accuracy of refraction prediction after intraocular lens (IOL) exchange using a software integrated in a Scheimpflug-based biometer. Setting: 2 tertiary referral hospitals. Design: Case series. Methods: Eyes that underwent uneventful bag-to-bag IOL exchange between 2017 and 2024 and complete preoperative and postoperative measurements were included. IOL exchange was performed by 2 experienced surgeons. IOL power was calculated using the Barrett RX formula integrated in Pentacam software, incorporating both phakic and pseudophakic biometric data and subjective refraction. Prediction errors were computed by comparing actual postoperative and predicted refractions. Moreover, an unpublished estimation formula was evaluated. Results: 25 eyes of 25 patients (mean age 60.2 ± 11.4 years) were included. Mean interval between primary IOL implantation and exchange was 25.3 ± 31.5 weeks. In 11 of 25 eyes, a different IOL model was implanted during the exchange. Using the Barrett RX formula, the mean prediction error (MPE) was 0.02 ± 0.32 diopters (D), mean absolute error (MAE) 0.27 ± 0.17 D, and median absolute error (MedAE) 0.22 D. A total of 56% and 92% of eyes were within ±0.25 D and ±0.50 D of target refraction, respectively. The conventional formula yielded a comparable MPE of –0.12 ± 0.68 D ( P = .479), but higher MAE and MedAE (0.53 ± 0.42 D and 0.40 D, P < .001), with 32% and 56% of eyes within ±0.25 D and ±0.50 D, respectively. Conclusions: The Barrett RX formula was demonstrated to be an efficacious method for calculating IOL power in eyes undergoing IOL exchange, with more than half of cases within ±0.25 D of the predicted postexchange refraction.

24 December 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
TJTyll Jandewerth
Tyll Jandewerth
PDPetra Davidova
Petra Davidova
TKThomas Kohnen
Thomas Kohnen
Purpose: To determine characteristics and differences in intraocular lens (IOL) exchange between eyes with an open (OPC) and closed posterior capsule (CPC). Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Design: Retrospective case series and review of literature. Methods: Charts of all cases of IOL exchange between January 2010 and May 2024 were retrospectively reviewed. Main outcome measures were indications for surgery, IOL implantation technique, and the necessity of anterior vitrectomy. MEDLINE database and Google scholar were used to identify relevant past publications. Results: We included 37 eyes of 30 patients with a mean age of 62.1 ± 10.2 years, with 16 eyes (43.2%) with OPC undergoing IOL exchange. Mean interval between IOL implantation and IOL exchange was 61.50 ± 62.00 months in the OPC group and 15.81 ± 15.03 months in the CPC group. The most common indication was optical phenomena in 18 cases (48%). In the OPC group, intraoperative anterior vitrectomy was necessary twice as often (OPC nine cases (56%) vs. CPC five cases (24%)). Bag-to-bag IOL exchange was performed in all eyes with CPC, and in 10/16 (62%) with OPC (p=0.009). Postoperative complications were seen in a total of 7/16 eyes (43.7%) with OPC and 3/21 (14.3%) with CPC (p=0.012). Conclusion: The success rate of repositioning an IOL within a bag with OPC is less than that achieved with CPC. A vitrectomy is typically required when attempting a bag-to-bag IOL exchange with an OPC. Capsulotomy should only be performed if the necessity of an IOL exchange is unlikely.

1 March 2026 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
JWJakob Wend
Jakob Wend
PDPetra Davidova
Petra Davidova
TJTyll Jandewerth
Tyll Jandewerth
ZOZubeida H. Omerovic
Zubeida H. Omerovic
TKThomas Kohnen
Thomas Kohnen
Purpose: To analyze the 8-year results of femtosecond laser–assisted in situ keratomileusis (LASIK) combined with simultaneous accelerated corneal crosslinking (LASIK-Xtra) compared with conventional LASIK (convLASIK). Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye–controlled clinical trial. Methods: Patients who received randomized treatment with the LASIK-Xtra (30 mW/cm 2 , 90 seconds with continuous UV-A) in 1 eye and convLASIK in the fellow eye were subjected 1 year (pos1y), and 8 years postoperatively (pos8y) to subjective refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell count (ECC), biomechanical evaluation, and tomographic examination. Results: 26 eyes (−7.07 ± 1.86 diopter [D]) from 13 patients (mean age 30.7 ± 10.4 years) were included. UDVA and CDVA were insignificantly different at pos1y and pos8y between convLASIK and LASIK-Xtra (each P > .28). The safety index at pos8y was 1.09 for convLASIK and 1.15 for LASIK-Xtra ( P = .799), and the efficacy index 0.91 and 0.94 ( P = .875), respectively. Significant myopic shift in spherical equivalent between pos1y (−0.30 ± 0.40 D) and pos8y (−0.80 ± 0.86 D) was found in the convLASIK group ( P = .018), compared the LASIK-Xtra group (−0.25 ± 0.49 D and −0.40 ± 0.86 D; P = .261), respectively. However, these refractive changes cannot be fully attributed to corneal alterations alone and may also reflect other factors. Insignificant differences in mean keratometry, corneal thickness, and ECC were found at pos8y ( P > .05). The stress–strain index was the only biomechanical parameter that was significantly higher in the LASIK-Xtra group at pos8y ( P = .034). Conclusions: After 8 years, no substantial disparities in efficacy and safety indices were observed between the 2 groups. There were no substantial differences in most of the evaluated postoperative corneal biomechanical parameters between the 2 groups. However, these findings need to be validated by further studies with larger sample sizes.

12 July 2024 in Acta Ophthalmologica
Verified
Journal Article
Open access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
JBJulian Bucur
Julian Bucur
TJTyll Jandewerth
Tyll Jandewerth
TKThomas Kohnen
Thomas Kohnen
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
Purpose: To evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.Methods: In this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe‐University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL‐FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with ±0.50, ±1.00 and ±2.00 dioptres (D) deviation from the target refraction was compared.Results: In total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL‐FE group (1.02 D). Comparison between the AL‐FE and FE groups showed no statistically significant difference (p = 0.712). Comparing eyes within ±0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL‐FE group (27.8%) and the FE group (26.6%).Conclusion: Our results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two‐step procedure should always be strived for.

19 February 2026 in American Journal of Ophthalmology
Verified
Journal Article
Open access
PDPetra Davidova
Petra Davidova
MRMark Rostom
Mark Rostom
LTLuca Gabriel Timoceanu
Luca Gabriel Timoceanu
TSTitus Schug
Titus Schug
KKKlemens Paul Kaiser
Klemens Paul Kaiser
TKThomas Kohnen
Thomas Kohnen
To evaluate the agreement between subjective refraction (SR) and objective refraction (OR) obtained by an autorefractor (AR), Hartmann-Shack aberrometer, and ray-tracing aberrometer after implantation of a wavefront-shaping extended-depth-of-focus (EDOF) or diffractive simultaneous vision intraocular lens (SVIOL) and to assess the potential influences of biometric parameters. Prospective, comparative assessment agreement analysis. Patients with healthy eyes, without previous surgeries, implanted with an EDOF (group A) or SVIOL (group B). SR performed by experienced opticians and OR with the 3 devices were compared for spherical and cylindrical refractive error, spherical equivalent (SE), and vector components. Axial length, pupil size, intraocular lens (IOL) power, and torus were analyzed as influential factors. Agreement of SE and spherical and cylindrical refractive error including vector analysis obtained by SR and OR with different devices. Group A comprised 42 eyes, and group B comprised 56 eyes. Mean SE was -0.11 diopters (D) (SR), -0.42 D (AR), -0.40 D (Hartmann-Shack), and -0.29 D (ray-tracing) for group A, and +0.18 D, +0.08 D, -0.03 D, and +0.23 D, respectively, for group B. Significant differences between SR and OR were found for most parameters, whereas none were found between vector components. Intraclass correlation coefficients between SR and OR were mostly poor-maximal moderate and poor for vector analysis. The highest proportion of eyes with an absolute difference ≤0.50 D between SR and OR was achieved with ray-tracing aberrometry in group A (79.5%) and with AR in group B (96.4%). Pupil size significantly affected SE differences between SR and Hartmann-Shack aberrometry in groups A and B, with the latter also being influenced by IOL toricity. OR with modern devices is not interchangeable with SR after implantation of the studied IOLs; agreement was greater for group B. Pupil size and partially IOL toricity had an impact on SE difference between SR and OR obtained by Hartmann-Shack aberrometry.