Michael T. Kuczynski

Michael T. Kuczynski

Auto-generated profile, based on publicly available information

Michael T. Kuczynski

McCaig Institute for Bone and Joint Health, University of Calgary , Calgary, AB

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2021 in Current Osteoporosis Reports
Verified
Journal Article
Closed access
PDF file
JTJustin J. Tse
Justin J. Tse
ASAinsley C. J. Smith
Ainsley C. J. Smith
MKMichael T. Kuczynski
Michael T. Kuczynski
DKDaphne A. Kaketsis
Daphne A. Kaketsis
SMSarah L. Manske
Sarah L. Manske

17 October 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ASAinsley C. J. Smith
Ainsley C. J. Smith
JTJustin J. Tse
Justin J. Tse
TWTadiwa H. Waungana
Tadiwa H. Waungana
KBKirsten N. Bott
Kirsten N. Bott
MKMichael T. Kuczynski
Michael T. Kuczynski
SMSarah L. Manske
Sarah L. Manske
Introduction: Muscle weakness can lead to reduced physical function and quality of life. Computed tomography (CT) can be used to assess muscle health through measures of muscle cross-sectional area and density loss associated with fat infiltration. However, there are limited opportunities to measure muscle density in clinically acquired CT scans because a density calibration phantom, allowing for the conversion of CT Hounsfield units into density, is typically not included within the field-of-view. For bone density analysis, internal density calibration methods use regions of interest within the scan field-of-view to derive the relationship between Hounsfield units and bone density, but these methods have yet to be adapted for muscle density analysis. The objective of this study was to design and validate a CT internal calibration method for muscle density analysis. Methodology: We CT scanned 10 bovine muscle samples using two scan protocols and five scan positions within the scanner bore. The scans were calibrated using internal calibration and a reference phantom. We tested combinations of internal calibration regions of interest (e.g., air, blood, bone, muscle, adipose). Results: We found that the internal calibration method using two regions of interest, air and adipose or blood, yielded accurate muscle density values (< 1% error) when compared with the reference phantom. The muscle density values derived from the internal and reference phantom calibration methods were highly correlated (R2 > 0.99). The coefficient of variation for muscle density across two scan protocols and five scan positions was significantly lower for internal calibration (mean = 0.33%) than for Hounsfield units (mean = 6.52%). There was no difference between coefficient of variation for the internal calibration and reference phantom methods. Conclusions: We have developed an internal calibration method to produce accurate and reliable muscle density measures from opportunistic computed tomography images without the need for calibration phantoms.

30 May 2024 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
MKMichael T. Kuczynski
Michael T. Kuczynski
NNNathan J. Neeteson
Nathan J. Neeteson
KSKathryn S. Stok
Kathryn S. Stok
ABAndrew J. Burghardt
Andrew J. Burghardt
MHMichelle A. Espinosa Hernandez
Michelle A. Espinosa Hernandez
SMSarah L. Manske
Sarah L. Manske

13 June 2024 in Osteoarthritis Imaging
Verified
Journal Article
Open access
MKMichael T. Kuczynski
Michael T. Kuczynski
JTJustin J. Tse
Justin J. Tse
GDGurpreet Dhaliwal
Gurpreet Dhaliwal
CHChristina Hiscox
Christina Hiscox
MVMartina Vergouwen
Martina Vergouwen
SMSarah L. Manske
Sarah L. Manske
Osteoarthritis affects joints of the hand and is radiographically characterized by joint space narrowing and changes in volumetric bone mineral density (vBMD). High-resolution peripheral computed tomography (HR-pQCT) allows for three-dimensional analysis of joint space width (JSW) changes but has yet to be applied to hand OA (HOA). The purpose of this study was to assess the utility of HR-pQCT in quantifying JSW and vBMD changes in HOA. The 2nd and 3rd distal interphalangeal (DIP2, DIP3) and trapeziometacarpal (TMC) joints of 20 women (10 controls, 10 HOA) were scanned using HR-pQCT. The Diseases of the Arm, Shoulder, and Hand (DASH) questionnaire and the Jebsen Hand Function Test (JHFT) were obtained. Radiographs were scored using the Eaton-Littler classification. We assessed between-group differences in HR-pQCT outcomes, and relationships between HR-pQCT outcomes and patient and radiographic characteristics. JSW maximum (JSW.Max) was higher in OA patients in the DIP2 (OA median [interquartile rage]: 2.07 mm [1.90–2.18], controls: 1.88 mm [1.84–1.89]) and DIP3 joints (OA: 2.01 mm [1.89–2.24], controls: 1.86 mm [1.82–1.95]). DIP3 JS volume was higher in OA (30.36 mm3, 19.35–34.57 mm3, controls: 17.05 mm3, 15.53–18.52 mm3). DASH scores were positively associated with DIP2 JSW asymmetry (JSW.AS), and JHFT times were positively associated with DIP3 JSW.Max, JSW.AS, and proximal DIP2 vBMD. Worsening radiographic TMC OA was associated with first metacarpal vBMD, JSW minimum, JSW.Max, and JSW.AS. These preliminary findings suggest that HR-pQCT may be useful in investigating JS changes in HOA and warrants further investigation.

18 December 2025 in JBMR Plus
Verified
Journal Article
Open access
TWTadiwa H Waungana
Tadiwa H Waungana
RMRia Mangat
Ria Mangat
CCChloe Chen
Chloe Chen
ASAinsley C J Smith
Ainsley C J Smith
YAYousif Al-Khoury
Yousif Al-Khoury
SMSarah L. Manske
Sarah L. Manske
Bone alterations and degenerative joint structural changes are frequently observed in knee osteoarthritis (OA). Objective measures of subchondral bone plate thickness (SBP.Th), apparent BMD, and joint space width (JSW) have begun to be used to better assess and understand disease progression. Weight-bearing CT (WBCT) allows 3D assessment of multiple bone and joint parameters; however, there is a paucity of literature investigating factors that might affect our ability to track changes over time. The purpose of this study was to investigate the repeatability of BMD, JSW, and SBP.Th measures obtained from WBCT images. Same-day, scan–rescan, knee WBCT images were acquired from 37 healthy adults (20 female, mean age: 24.6 yr). We quantified trabecular bone BMD at the proximal tibia and implemented joint space and cortical bone mapping to measure tibiofemoral JSW and SBP.Th, respectively. Test–retest repeatability was evaluated using coefficients of variation (CVRMS%) and least significant change (LSC). Mean trabecular BMD exhibited CVRMS% ranging from 1.87% to 2.85% and LSCs between 13.53 and 17.39 mgHA/cm3. For JSW, CVRMS% and LSC were less than 1% and 0.2 mm, respectively. SBP.Th measures had higher CVRMS% (9.75%-11.29%) but similar LSC values (0.09-0.26 mm) in comparison to JSW values. The high repeatability of subchondral bone and joint parameters underscore the potential of WBCT for quantifying and monitoring bone and joint changes in knee OA progression and management. However, standardization of acquisition and analysis methods will likely be required to ensure reliable evaluation over multiple time points.

20 February 2026 in JBMR Plus
Verified
Journal Article
Open access
PDF file
SBSerena Bonaretti
Serena Bonaretti
MBMojtaba Barzegari
Mojtaba Barzegari
MBMelissa Bevers
Melissa Bevers
SBSteven Kyle Boyd
Steven Kyle Boyd
ABAndrew J Burghardt
Andrew J Burghardt
DZDženan Zukić
Dženan Zukić
The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community is a scientific community dedicated to promoting openness and reproducibility in musculoskeletal imaging, image processing, and computational modelling. In this perspective paper, we outline the motivations for conducting transparent research and provide practical guidelines to implement it. We start with defining open and reproducible research and describing the benefits and challenges of working transparently. Next, we redefine the outputs of a computational research study as—ideally—a combination of data, code, and a publication, recommend a folder and file structure that reflects these three study outcomes, and describe how to maintain and update such a structure during the study and at study publication. Finally, we emphasize that working in an open and reproducible manner is a learning process and the best way to acquire the necessary competencies is simply to start. Lay summary: The ORMIR community promotes openness and reproducibility in musculoskeletal imaging research. In this perspective paper, we explain why transparency matters and recommend how to conduct a computational study in an open and reproducible manner focusing on its three outputs: data, code, and publication. Finally, we highlight that the best way to learn these practices is simply to start.