5 December 2025 in IEEE Sensors Journal
This paper proposes a temperature-salt synchronous sensitisation detection technique based on data signal processing (DSP). The method first employs spectral analysis to decouple the independent interference spectra of each cavity from the combined interference spectrum of the parallel dual-cavity system. Subsequently, a virtual interferogram corresponding to each independent interferogram is constructed, and the two are superimposed to generate their respective vernier effect spectra. Finally, based on the relationship between the envelope peaks (or troughs) of the two vernier spectra and variations in temperature and salinity, a sensitivity matrix equation is established, thereby achieving highly sensitive simultaneous detection of temperature and salinity parameters. Experimental results indicate that within the temperature range of 21°C to 28°C, the temperature sensitivities of the dual-vernier spectrum are -2.0544 nm/°C and -4.9609 nm/°C, respectively, representing 8.08 times and 5.83 times the sensitivity of a single independent cavity. Within a salinity range of 20‰ to 50‰, the salinity sensitivities of the dual-vernier spectra were 1.4248 nm/‰ and 0, respectively, representing 7.98 times and 0 times the sensitivity of a single independent cavity. This method, requiring no physical interferometer and relying solely on algorithms, not only achieves simultaneous measurement of both temperature and salinity parameters but also realizes sensitivity amplification. This method offers simplicity of implementation, high sensitivity, and low cost, demonstrating promising application prospects in the field of high-sensitivity marine sensing.