Piotr Gucwa

Piotr Gucwa

Auto-generated profile, based on publicly available information

Piotr Gucwa

Research and Development, SMA-Magnetics Sp. z o.o., Komandosów 3/1, 32-085 Modlniczka, Poland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AMAndrzej Mondzik
Andrzej Mondzik
RSRobert Stala
Robert Stala
SPStanislaw Pirog
Stanislaw Pirog
APAdam Penczek
Adam Penczek
PGPiotr Gucwa
Piotr Gucwa
MSMilosz Szarek
Milosz Szarek
This article presents a novel concept of switch-mode dc–dc boost converters with reduced switching losses. The converters use an auxiliary switching cell to achieve zero voltage switching during the turn- off of a transistor. The novel concept facilitates an increase in the efficiency or switching frequency of an IGBT-based boost converter. This article discusses the converters topology, the principle of operation, and issues related to the reduction of power losses, the range of optimal operation, and selection of components. The concept of the converter was verified through simulation and a series of experiments that demonstrate the process of zero-voltage turn- off and the efficiency of the converter.

29 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
AMAndrzej Mondzik
Andrzej Mondzik
MBMarcin Baszynski
Marcin Baszynski
RSRobert Stala
Robert Stala
APAdam Penczek
Adam Penczek
PGPiotr Gucwa
Piotr Gucwa
This article presents the results of research on a new topology of a DC-DC converter in which switching losses are reduced by an auxiliary switching circuit (ASC). The proposed ASC can work as a passive or active circuit depending on the voltage gain of the converter. In both cases, this does not affect the operation of the main circuit and is analogous to a classic boost converter, which allows the use of the same control circuits and methods. The operation of the ASC is synchronized with the control of the main converter transistor. The reduction of transistor turn-off losses over a wide range of converter gain is a unique advantage of the proposed auxiliary circuit. This is evidenced by the comparison of the loss reduction with the classic boost converter and the reference converter with soft turn off. This article presents an in-depth analytical discussion related to the reduction of power losses, supported by simulation results, and verified experimentally.