1 September 2021 in Talanta
1 January 2022 in Analytica Chimica Acta
14 December 2024 in Analytica Chimica Acta
DSDanielle da Silva Sousa
5 December 2023 in Lab on a Chip
Multiple protocols have been reported to fabricate paper-based analytical devices (PADs). However, some of these techniques must be revised because of the instrumentation required. This paper describes a versatile and globally affordable method to fabricate PADs using office paper as a substrate and a laser printing technique to define hydrophobic barriers on paper surfaces. To demonstrate the feasibility of the alternatives proposed in this study, the fabrication of devices for three types of detection commonly associated with using PADs was demonstrated: colorimetric detection, electrochemical detection, and mass spectrometry associated with a paper-spray ionization (PSI-MS) technique. Besides that, an evaluation of the type of paper used and chemical modifications required on the substrate surface are also presented in this report. Overall, the developed protocol was suitable for using office paper as a substrate, and the laser printing technique as an efficient fabrication method when using this substrate is accessible at a resource-limited point-of-need. Target analytes were used as a proof of concept for these detection techniques. Colorimetric detection was carried out for acetaminophen, iron, nitrate, and nitrite with limits of detection of 0.04 μg, 4.5 mg mL−1, 2.7 μmol L−1, and 6.8 μmol L−1, respectively. A limit of detection of 0.048 fg mL−1 was obtained for the electrochemical analysis of prostate-specific antigen. Colorimetric and electrochemical devices revealed satisfactory performance when office paper with a grammage of 90 g m−2 was employed. Methyldopa analysis was also carried out using PSI-MS, which showed a good response in the same paper weight and behavior compared to chromatographic paper.
21 November 2023 in Analytical Methods
This study presents the development of a polyester microplate for detecting the S-protein of the SARS-CoV-2 virus in saliva and nasopharyngeal swab samples using direct enzyme-linked immunosorbent assay (ELISA) technology. The polyester microplate was designed to contain 96 zones with a 3 mm diameter each, and a volume of 2–3 μL. The experimental conditions including reagent concentration and reaction time were optimized. The microplate image was digitized and analyzed using graphical software. The linear range obtained between protein S concentrations and pixel intensity was 0–10 μg mL−1, with a correlation coefficient of 0.99 and a limit of detection of 0.44 μg mL−1. The developed methodology showed satisfactory intraplate and interplate repeatability with RSD values lower than 7.8%. The results achieved through immunoassay performed on polyester microplates were consistent with those of the RT-PCR method and showed a sensitivity of 100% and 90% and specificity of 85.71% and 100% for saliva and nasopharyngeal samples, respectively. The proposed direct immunoassay on polyester microplates emerges as an alternative to conventional immunoassays performed on commercial polystyrene plates, given the low cost of the device, low consumption of samples and reagents, lower waste generation, and shorter analysis time. Moreover, the immunoassay has shown great potential for diagnosing COVID-19 with precision and accuracy.
11 September 2026 in Journal of Chemical Education
JSJordanna Emily dos Santos
Jordanna Emily dos Santos
GSGabrielly Rodrigues da Silva
Gabrielly Rodrigues da Silva
MJMaria Eduarda Oliveira de Jesus
Maria Eduarda Oliveira de Jesus
In this study, paper-based analytical devices (PADs) were used to introduce a simple, rapid, portable, and low-cost acid–base titration method in high school chemistry laboratories. Students performed conventional and paper-based titrations to determine the amount of acetylsalicylic acid in aspirin® tablets. This learning laboratory experiment aimed to introduce the concept of PADs and fundamentals of acid–base titrations to students, as well as to evaluate their perceptions of both titration methods, such as portability, waste generation, solution volume consumption, and how it contributed to their learning experience and skills through a questionnaire. Thirty-two high school students conducted this laboratory experiment over four 90 min classes during the second semester of 2025. The students’ assessment was very satisfactory, and in general, this laboratory experiment contributed to their learning experience during high school.