William D. Rooney

William D. Rooney

Auto-generated profile, based on publicly available information

William D. Rooney

Advanced Imaging Research Center Oregon Health & Science University Portland Oregon USA

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2007 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WRWilliam D. Rooney
William D. Rooney
GJGlyn Johnson
Glyn Johnson
XLXin Li
Xin Li
ECEric R. Cohen
Eric R. Cohen
SKSeong‐Gi Kim
Seong‐Gi Kim
CSCharles S. Springer
Charles S. Springer
Brain water proton (1H2O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5‐mm midventricular axial slice was sampled using a modified Look‐Locker technique with 1.5 mm in‐plane resolution, and 32 time points post‐adiabatic inversion. The results confirmed that for most brain tissues, T1 values increased by more than a factor of 3 between 0.2T and 7T, and over this range were well fitted by T1 (s) = 0.583(B0)0.382, T1(s) = 0.857(B0)0.376, and T1(s) = 1.35(B0)0.340 for white matter (WM), internal GM, and blood 1H2O, respectively. The ventricular cerebrospinal fluid (CSF) 1H2O T1 value did not change with B0, and its average value (standard deviation (SD)) across subjects and magnetic fields was 4.3 (±0.2) s. The tissue 1/T1 values at each field were well correlated with the macromolecular mass fraction, and to a lesser extent tissue iron content. The field‐dependent increases in 1H2O T1 values more than offset the well‐known decrease in typical MRI contrast reagent (CR) relaxivity, and simulations predict that this leads to lower CR concentration detection thresholds with increased magnetic field. Magn Reson Med 57:308–318, 2007.

22 June 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
RSR.T. Shinohara
R.T. Shinohara
JOJ. Oh
J. Oh
GNGovind Nair
Govind Nair
PCPeter A Calabresi
Peter A Calabresi
CDChristos Davatzikos
Christos Davatzikos
TCthe NAIMS Cooperative
the NAIMS Cooperative
BACKGROUND AND PURPOSE: MR imaging can be used to measure structural changes in the brains of individuals with multiple sclerosis and is essential for diagnosis, longitudinal monitoring, and therapy evaluation. The North American Imaging in Multiple Sclerosis Cooperative steering committee developed a uniform high-resolution 3T MR imaging protocol relevant to the quantification of cerebral lesions and atrophy and implemented it at 7 sites across the United States. To assess intersite variability in scan data, we imaged a volunteer with relapsing-remitting MS with a scan-rescan at each site. MATERIALS AND METHODS: All imaging was acquired on Siemens scanners (4 Skyra, 2 Tim Trio, and 1 Verio). Expert segmentations were manually obtained for T1-hypointense and T2 (FLAIR) hyperintense lesions. Several automated lesion-detection and whole-brain, cortical, and deep gray matter volumetric pipelines were applied. Statistical analyses were conducted to assess variability across sites, as well as systematic biases in the volumetric measurements that were site-related. RESULTS: Systematic biases due to site differences in expert-traced lesion measurements were significant (P < .01 for both T1 and T2 lesion volumes), with site explaining >90% of the variation (range, 13.0–16.4 mL in T1 and 15.9–20.1 mL in T2) in lesion volumes. Site also explained >80% of the variation in most automated volumetric measurements. Output measures clustered according to scanner models, with similar results from the Skyra versus the other 2 units. CONCLUSIONS: Even in multicenter studies with consistent scanner field strength and manufacturer after protocol harmonization, systematic differences can lead to severe biases in volumetric analyses.

1 January 2015 in NeuroImage: Clinical
Verified
Journal Article
Open access
NPN. Promjunyakul
N. Promjunyakul
DLD. Lahna
D. Lahna
JBJoan Benedict
Joan Benedict
HDH.H. Dodge
H.H. Dodge
DED. Erten-Lyons
D. Erten-Lyons
LSLisa Silbert
Lisa Silbert
White matter hyperintensities (WMHs) are common with age, grow over time, and are associated with cognitive and motor impairments. Mechanisms underlying WMH growth are unclear. We aimed to determine the presence and extent of decreased normal appearing white matter (NAWM) cerebral blood flow (CBF) surrounding WMHs to identify 'WM at risk', or the WMH CBF penumbra. We aimed to further validate cross-sectional finding by determining whether the baseline WMH penumbra CBF predicts the development of new WMHs at follow-up. Sixty-one cognitively intact elderly subjects received 3 T MPRAGE, FLAIR, and pulsed arterial spin labeling (PASL). Twenty-four subjects returned for follow-up MRI. The inter-scan interval was 18 months. A NAWM layer mask, comprised of fifteen layers, 1 mm thick each surrounding WMHs, was generated for periventricular (PVWMH) and deep (DWMH) WMHs. Mean CBF for each layer was computed. New WMH and persistent NAWM voxels for each penumbra layer were defined from follow-up MRI. CBF in the area surrounding WMHs was significantly lower than the total brain NAWM, extending approximately 12 mm from both the established PVWMH and DWMH. Voxels with new WMH at follow-up had significantly lower baseline CBF than voxels that maintained NAWM, suggesting that baseline CBF can predict the development of new WMHs over time. A CBF penumbra exists surrounding WMHs, which is associated with future WMH expansion. ASL MRI can be used to monitor interventions to increase white matter blood flow for the prevention of further WM damage and its cognitive and motor consequences.

7 April 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ITIan Tagge
Ian Tagge
AOAudrey O'Connor
Audrey O'Connor
PCPriya Chaudhary
Priya Chaudhary
JPJim Pollaro
Jim Pollaro
YBYosef Berlow
Yosef Berlow
WRWilliam Rooney
William Rooney
Cuprizone administration in mice provides a reproducible model of demyelination and spontaneous remyelination, and has been useful in understanding important aspects of human disease, including multiple sclerosis. In this study, we apply high spatial resolution quantitative MRI techniques to establish the spatio-temporal patterns of acute demyelination in C57BL/6 mice after 6 weeks of cuprizone administration, and subsequent remyelination after 6 weeks of post-cuprizone recovery. MRI measurements were complemented with Black Gold II stain for myelin and immunohistochemical stains for associated tissue changes. Gene expression was evaluated using the Allen Gene Expression Atlas. Twenty-five C57BL/6 male mice were split into control and cuprizone groups; MRI data were obtained at baseline, after 6 weeks of cuprizone, and 6 weeks post-cuprizone. High-resolution (100μm isotropic) whole-brain coverage magnetization transfer ratio (MTR) parametric maps demonstrated concurrent caudal-to-rostral and medial-to-lateral gradients of MTR decrease within corpus callosum (CC) that correlated well with demyelination assessed histologically. Our results show that demyelination was not limited to the midsagittal line of the corpus callosum, and also that opposing gradients of demyelination occur in the lateral and medial CC. T2-weighted MRI gray/white matter contrast was strong at baseline, weak after 6 weeks of cuprizone treatment, and returned to a limited extent after recovery. MTR decreases during demyelination were observed throughout the brain, most clearly in callosal white matter. Myelin damage and repair appear to be influenced by proximity to oligodendrocyte progenitor cell populations and exhibit an inverse correlation with myelin basic protein gene expression. These findings suggest that susceptibility to injury and ability to repair vary across the brain, and whole-brain analysis is necessary to accurately characterize this model. Whole-brain parametric mapping across time is essential for gaining a real understanding of disease processes in-vivo. MTR increases in healthy mice throughout adolescence and adulthood were observed, illustrating the need for appropriate age-matched controls. Elucidating the unique and site-specific demyelination in the cuprizone model may offer new insights into in mechanisms of both damage and repair in human demyelinating diseases.

27 April 2015 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
WRWilliam D. Rooney
William D. Rooney
XLXin Li
Xin Li
MSManoj K. Sammi
Manoj K. Sammi
DBDennis N. Bourdette
Dennis N. Bourdette
ENEdward A. Neuwelt
Edward A. Neuwelt
CSCharles S. Springer
Charles S. Springer
Shutter‐speed analysis of dynamic‐contrast‐agent (CA)‐enhanced normal, multiple sclerosis (MS), and glioblastoma (GBM) human brain data gives the mean capillary water molecule lifetime (τb) and blood volume fraction (vb; capillary density–volume product (ρ†V)) in a high‐resolution 1H2O MRI voxel (40 μL) or ROI. The equilibrium water extravasation rate constant, kpo (τb−1), averages 3.2 and 2.9 s−1 in resting‐state normal white matter (NWM) and gray matter (NGM), respectively (n = 6). The results (italicized) lead to three major conclusions. (A) kpo differences are dominated by capillary water permeability (PW†), not size, differences. NWM and NGM voxel kpo and vb values are independent. Quantitative analyses of concomitant population‐averaged kpo, vb variations in normal and normal‐appearing MS brain ROIs confirm PW† dominance. (B) PW† is dominated (>95%) by a trans(endothelial)cellular pathway, not the PCA† paracellular route. In MS lesions and GBM tumors, PCA† increases but PW† decreases. (C) kpo tracks steady‐state ATP production/consumption flux per capillary. In normal, MS, and GBM brain, regional kpo correlates with literature MRSI ATP (positively) and Na+ (negatively) tissue concentrations. This suggests that the PW† pathway is metabolically active. Excellent agreement of the relative NGM/NWM kpovb product ratio with the literature 31PMRSI‐MT CMRoxphos ratio confirms the flux property. We have previously shown that the cellular water molecule efflux rate constant (kio) is proportional to plasma membrane P‐type ATPase turnover, likely due to active trans‐membrane water cycling. With synaptic proximities and synergistic metabolic cooperativities, polar brain endothelial, neuroglial, and neuronal cells form “gliovascular units.” We hypothesize that a chain of water cycling processes transmits brain metabolic activity to kpo, letting it report neurogliovascular unit Na+,K+‐ATPase activity. Cerebral kpo maps represent metabolic (functional) neuroimages. The NGM 2.9 s−1 kpo means an equilibrium unidirectional water efflux of ~1015 H2O molecules s−1 per capillary (in 1 μL tissue): consistent with the known ATP consumption rate and water co‐transporting membrane symporter stoichiometries. © 2015 The Authors NMR in Biomedicine Published by John Wiley & Sons Ltd.

14 August 2020 in NeuroImage
Verified
Journal Article
Open access
JWJulia Wrobel
Julia Wrobel
MMM.L. Martin
M.L. Martin
RBR. Bakshi
R. Bakshi
PCP.A. Calabresi
P.A. Calabresi
MEM. Elliot
M. Elliot
JGJ. Goldsmith
J. Goldsmith
In multisite neuroimaging studies there is often unwanted technical variation across scanners and sites. These “scanner effects” can hinder detection of biological features of interest, produce inconsistent results, and lead to spurious associations. We propose mica (multisite image harmonization by cumulative distribution function alignment), a tool to harmonize images taken on different scanners by identifying and removing within-subject scanner effects. Our goals in the present study were to (1) establish a method that removes scanner effects by leveraging multiple scans collected on the same subject, and, building on this, (2) develop a technique to quantify scanner effects in large multisite studies so these can be reduced as a preprocessing step. We illustrate scanner effects in a brain MRI study in which the same subject was measured twice on seven scanners, and assess our method’s performance in a second study in which ten subjects were scanned on two machines. We found that unharmonized images were highly variable across site and scanner type, and our method effectively removed this variability by aligning intensity distributions. We further studied the ability to predict image harmonization results for a scan taken on an existing subject at a new site using cross-validation.