Hyun-Ju Lee

Hyun-Ju Lee

Auto-generated profile, based on publicly available information

Hyun-Ju Lee

Department of Radiology, Seoul National University Hospital, Seoul, Korea

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Journal of Thoracic Oncology
Verified
Journal Article
Closed access
YSYoung Joo Suh
Young Joo Suh
HLHyun-Ju Lee
Hyun-Ju Lee
PSPamela Sung
Pamela Sung
HYHeera Yoen
Heera Yoen
SKSewoo Kim
Sewoo Kim
YKYoung Tae Kim
Young Tae Kim

6 February 2019 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
YKYoung Jae Kim
Young Jae Kim
HLHyun-Ju Lee
Hyun-Ju Lee
KKKwang Gi Kim
Kwang Gi Kim
SLSeung Hyun Lee
Seung Hyun Lee
The purpose of this study was to explore the effects of CT slice thickness, reconstruction algorithm, and radiation dose on quantification of CT features to characterize lung nodules using a chest phantom. Spherical lung nodule phantoms of known densities (−630 and + 100 HU) were inserted into an anthropomorphic thorax phantom. CT scan was performed ten times with relocations. CT data were reconstructed using 12 different imaging settings; three different slice thicknesses of 1.25, 2.5, and 5.0 mm, two reconstruction kernels of sharp and standard, and two radiation dose of 30 mAs and 12 mAs. Lesions were segmented using a semiautomated method. Twenty representative CT quantitative features representing CT density and texture were compared using multiple regression analysis. In 100 HU nodule phantoms, 18 and 19 among 20 computer features showed significant difference between different mAs and reconstruction algorithms, respectively (p≤0.05). 20, 19, and 19 computer features showed difference between slice thickness of 5.0 vs 1.25, 5.0 vs 2.5, and 2.5 vs 1.25 mm, respectively (p≤0.05). In −630 HU nodule phantoms, 18 and 19 showed significant difference between different mAs and reconstruction algorithms, respectively (p≤0.05). 18, 11, and 17 computer features showed difference between slice thickness of 5.0 vs 1.25, 5.0 vs 2.5, and 2.5 vs 1.25 mm, respectively (p≤0.05). When comparing the absolute value of regression coefficient, the effect of slice thickness in 100 HU nodule and reconstruction algorithm in −630 HU nodule was greater than the effect of remaining scan parameters. The slice thickness, mAs, and reconstruction algorithm had a significant impact on the quantitative image features. In clinical studies involving deep learning or radiomics, it should be noted that differences in values can occur when using computer features obtained from different CT scan parameters in combination. Therefore, when interpreting the statistical analysis results, it is necessary to reflect the difference in the computer features depending on the scan parameters.

1 September 2018 in Lung Cancer
Verified
Journal Article
Closed access
YSYoung Joo Suh
Young Joo Suh
HLHyun-Ju Lee
Hyun-Ju Lee
YKYoung Jae Kim
Young Jae Kim
KKKwang Gi Kim
Kwang Gi Kim
HKHeekyung Kim
Heekyung Kim
YKYoung Tae Kim
Young Tae Kim

1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
SLSang Hyup Lee
Sang Hyup Lee
SYSoon Ho Yoon
Soon Ho Yoon
Ju Gang NamJu Gang Nam
Ju Gang Nam
HKHyungjin Kim
Hyungjin Kim
SASu Yeon Ahn
Su Yeon Ahn
JGJin Mo Goo
Jin Mo Goo
Lee SH, et al. Korean J Radiol. 2019 Apr;20(4):671-682. https://doi.org/10.3348/kjr.2018.0400

1 July 2002 in Radiology
Verified
Journal Article
Closed access
JGJin Mo Goo
Jin Mo Goo
JIJung-Gi Im
Jung-Gi Im
HLHyun Ju Lee
Hyun Ju Lee
MCMyung Jin Chung
Myung Jin Chung
JSJoon Beom Seo
Joon Beom Seo
JKJong Hyo Kim
Jong Hyo Kim
To compare observer performance by using soft-copy images produced by an amorphous silicon flat-panel-detector system and a storage-phosphor system for the detection of simulated chest lesions. To test the diagnostic performance of these two systems, four types of simulated lesions (nodules, micronodules, lines, and reticular opacities) were superimposed over an anthropomorphic chest phantom. Digital chest radiographs were acquired with amorphous silicon flat-panel-detector (3-K [K = 1,000] matrix, 12 bits) and storage-phosphor radiography (4-K matrix, 10 bits). Six board-certified radiologists evaluated soft-copy images on a high-resolution video monitor (2,048 x 2,560 x 8 bits). A total of 14,400 observations were analyzed in terms of receiver operating characteristics. Average performance in terms of nodule detection was significantly better (P <.05) with the flat-panel-detector system than with the storage-phosphor system. For micronodules, lines, and reticular opacities, no significant detection differences in averaged performance were found between the two detector systems. In the evaluation of soft-copy images, the amorphous silicon detector system appears to be superior to the storage-phosphor system for the detection of pulmonary nodules.

15 October 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
JKJung Im Kim
Jung Im Kim
HLHyun-Ju Lee
Hyun-Ju Lee
YKYoung Jae Kim
Young Jae Kim
KKKwang Gi Kim
Kwang Gi Kim
KLKyung Won Lee
Kyung Won Lee
WLWon Woo Lee
Won Woo Lee
Objectives.To perform dual analysis of tumor perfusion and glucose metabolism using perfusion CT and FDG-PET/CT for the purpose of monitoring the early response to bevacizumab therapy in rabbit VX2 tumor models and to assess added value of FDG-PET to perfusion CT.Methods.Twenty-four VX2 carcinoma tumors implanted in bilateral back muscles of 12 rabbits were evaluated. Serial concurrent perfusion CT and FDG-PET/CT were performed before and 3, 7, and 14 days after bevacizumab therapy (treatment group) or saline infusion (control group). Perfusion CT was analyzed to calculate blood flow (BF), blood volume (BV), and permeability surface area product (PS); FDG-PET was analyzed to calculate SUVmax, SUVmean, total lesion glycolysis (TLG), entropy, and homogeneity. The flow-metabolic ratio (FMR) was also calculated and immunohistochemical analysis of microvessel density (MVD) was performed.Results.On day 14, BF and BV in the treatment group were significantly lower than in the control group. There were no significant differences in all FDG-PET-derived parameters between both groups. In the treatment group, FMR prominently decreased after therapy and was positively correlated with MVD.Conclusions.In VX2 tumors, FMR could provide further insight into the early antiangiogenic effect reflecting a mismatch in intratumor blood flow and metabolism.