Yulian Tan

Yulian Tan

Auto-generated profile, based on publicly available information

Yulian Tan

Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYiqing Liang
Yiqing Liang
XWXiaojun Wang
Xiaojun Wang
JLJiqiang Li
Jiqiang Li
HZHuajian Zhang
Huajian Zhang
YTYulian Tan
Yulian Tan
DGDaqing Gao
Daqing Gao
In High-Intensity Heavy Ion Accelerator Facility (HIAF), a high precision timing system is necessary because highly synchronous triggering of distributed power supply (PS) is essential for the facility operation. To obtain a cost-effective local area timing system, a nanosecond-accuracy private synchronization approach based on IEEE 1588 protocol is proposed. Instead of Ethernet protocol usually used, universal asynchronous transceiver protocol over dedicated optical fiber is applied in the method to avoid the uncertain delay in Ethernet architecture. Besides, the timing system simplifies the communication message formats and increases synchronization frequency to 1 kHz to reduce the timing deviation due to oscillator frequency deviation. The test results show that the implementation ensures a synchronization accuracy of better than ±10 ns with 2 ppm temperature-compensation crystal oscillator (TCXO) for dozens of distributed PS controllers.

31 July 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CHCheng Han
Cheng Han
LMLijun Mao
Lijun Mao
FWFeng-Jun Wu
Feng-Jun Wu
YHYuzheng Huang
Yuzheng Huang
YLYuan Li
Yuan Li
YDYonghua Deng
Yonghua Deng
We describe a new modular cascaded H-bridge high power accelerator dipole magnet pulse power supply for the HIRFL-CSRm (Heavy Ion Research Facility in Lanzhou-Cooler-Storage-Ring main ring). The power supply consists of two branches connected in parallel, each of which consists of four 360V/1800A power units connected in series. Each power unit utilizes modular high power density voltage sources in parallel for AC/DC converter and cascaded H-bridges for DC/DC converter. In addition, digital control strategies are implemented. The voltage source modules adopt voltage and current dual closed-loop control, and the cascaded H-bridges employ current dual closed-loop control with frequency doubling modulation and cascaded multilevel control. The effectiveness of the proposed topology scheme and control strategies is confirmed through experiments, and the thermal stability of the power supply is verified through 72-hour continuous output experiments.