Department of Computer Science Department of Radiation Oncology Department of Radiation Oncology Department of Computer Science Johns Hopkins University Johns Hopkins School of Medicine Johns Hopkins School of Medicine Anqi Liu Johns Hopkins University
Auto-generated profile, based on publicly available information
David P. Adam
Department of Computer Science Department of Radiation Oncology Department of Radiation Oncology Department of Computer Science Johns Hopkins University Johns Hopkins School of Medicine Johns Hopkins School of Medicine Anqi Liu Johns Hopkins University
Background and purpose. Chimeric antigen receptor (CAR) T cells have been relatively ineffective against solid tumors. Low-dose radiation which can be delivered to multiple sites of metastases by targeted radionuclide therapy (TRT) can elicit immunostimulatory effects. However, TRT has never been combined with CAR T cells against solid tumors in a clinical setting. This study investigated the effects of radiation delivered by Lutetium-177 (177Lu) and Actinium-225 (225Ac) on the viability and effector function of CAR T cells in vitro to evaluate the feasibility of such therapeutic combinations. After the irradiation of anti-GD2 CAR T cells with various doses of radiation delivered by 177Lu or 225Ac, their viability and cytotoxic activity against GD2-expressing human CHLA-20 neuroblastoma and melanoma M21 cells were determined by flow cytometry. The expression of the exhaustion marker PD-1, activation marker CD69 and the activating receptor NKG2D was measured on the irradiated anti-GD2 CAR T cells. Both 177Lu and 225Ac displayed a dose-dependent toxicity on anti-GD2 CAR T cells. However, radiation enhanced the cytotoxic activity of these CAR T cells against CHLA-20 and M21 irrespective of the dose tested and the type of radionuclide. No significant changes in the expression of PD-1, CD69 and NKG2D was noted on the CAR T cells following irradiation. Given a lower CAR T cell viability at equal doses and an enhancement of cytotoxic activity irrespective of the radionuclide type, 177Lu-based TRT may be preferred over 225Ac-based TRT when evaluating a potential synergism between these therapies in vivo against solid tumors.
Radiopharmaceutical therapies (RPT) activate a type I interferon (IFN1) response in tumor cells. We hypothesized that the timing and amplitude of this response varies by isotope. We compared equal doses delivered by 90Y, 177Lu, and 225Ac in vitro as unbound radionuclides and in vivo when chelated to NM600, a tumor-selective alkylphosphocholine. Response in murine MOC2 head and neck carcinoma and B78 melanoma was evaluated by qPCR and flow cytometry. Therapeutic response to 225Ac-NM600+anti-CTLA4+anti-PD-L1 immune checkpoint inhibition (ICI) was evaluated in wild-type and stimulator of interferon genes knockout (STING KO) B78. The timing and magnitude of the IFN1 response correlated with radionuclide half-life and linear energy transfer. The ratio of CD8+ T cells to regulatory T cells (Treg) increased in tumors 7 days after 90Y- and 177Lu-NM600 and day 21 after 225Ac-NM600. 225Ac-NM600+ICI improved survival in mice with wild-type but not with STING KO tumors, relative to monotherapies. Thus, we have found that the immunomodulatory effects of RPT vary with radioisotope and promote tumor cell STING-dependent enhanced response to ICIs in murine models. These findings have implications for the optimization of RPT–immunotherapy combinations and could guide the relative timing of therapies, the selection of isotope, and patient selection through tumor biomarkers.
Purpose: Approximately 50% of head and neck cancer (HNC) patients will experience loco‐regional disease recurrence following initial courses of therapy. Retreatment with external beam radiotherapy (EBRT) is technically challenging and may be associated with a significant risk of irreversible damage to normal tissues. Radiopharmaceutical therapy (RPT) is a potential method to treat recurrent HNC in conjunction with EBRT. Phantoms are used to calibrate and add quantification to nuclear medicine images, and anthropomorphic phantoms can account for both the geometrical and material composition of the head and neck. In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom, and its characterization for the validation of a Monte Carlo, SPECT image‐based, 131I RPT dosimetry workflow.Methods: 3D‐printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three 131I SPECT/CT imaging studies were performed using a homogeneous, Jaszczak, and an anthropomorphic phantom to quantify the SPECT images using a GE Optima NM/CT 640 with a high energy general purpose collimator. The impact of collimator detector response (CDR) modeling and volume‐based partial volume corrections (PVCs) upon the absorbed dose was calculated using an image‐based, Geant4 Monte Carlo RPT dosimetry workflow and compared against a ground truth scenario. Finally, uncertainties were quantified in accordance with recent EANM guidelines.Results: The 3D‐printed anthropomorphic phantom was an accurate re‐creation of patient anatomy including bone. The extrapolated Jaszczak recovery coefficients were greater than that of the 3D‐printed insert (∼22.8 ml) for both the CDR and non‐CDR cases (with CDR: 0.536 vs. 0.493, non‐CDR: 0.445 vs. 0.426, respectively). Utilizing Jaszczak phantom PVCs, the absorbed dose was underpredicted by 0.7% and 4.9% without and with CDR, respectively. Utilizing anthropomorphic phantom recovery coefficient overpredicted the absorbed dose by 3% both with and without CDR. All dosimetry scenarios that incorporated PVC were within the calculated uncertainty of the activity. The uncertainties in the cumulative activity ranged from 23.6% to 106.4% for Jaszczak spheres ranging in volume from 0.5 to 16 ml.Conclusion: The accuracy of Monte Carlo‐based dosimetry for 131I RPT in HNC was validated with an anthropomorphic phantom. In this study, it was found that Jaszczak‐based PVCs were sufficient. Future applications of the phantom could involve 3D printing and characterizing patient‐specific volumes for more personalized RPT dosimetry estimates.
It is a pathological paradox: how to meet cancer researchers' increasing demand for human tissue while public concern about its use reduces the amount available. Last week the European Organisation for Research and Treatment of Cancer (EORTC) unveiled its solution — an online library of tens of thousands of tumour tissue samples held at research centres and tissue banks across Europe. Under plans discussed at last month's EORTC conference in Brussels, participating researchers would browse through samples online and take enough tissue and associated clinical data to carry out molecular profiling and clinical trials. The frozen samples would be stored at the respective centres, and a representative section then scanned and entered into the virtual library. "By making more tissue more easily available to scientists we can speed up translational research tremendously," says Wolter Oosterhuis, a pathologist at University Hospital Rotterdam who is leading the project. An increase in both regulation and public scrutiny of the use of research tissue is making access to some materials increasingly difficult. Nick Lemoine, a cancer researcher at London's Hammersmith Hospital, says that supplies of tissue "almost dried up" in some parts of Britain following a series of high-profile scandals over retention of human tissue without consent. Others say that a shortage of pathologists and a tendency to take smaller amounts of material during each biopsy have made some tumour tissue harder to obtain. The plans are at an early stage, but Oosterhuis is hopeful that the system can be up and running within four years. It builds on a similar EORTC initiative to digitize thousands of slides of tissue samples to create a virtual tumour-tissue bank. Such slides allow physical comparison between samples, but fresh tissue is more useful as it allows investigation of DNA, RNA and protein expression, which researchers believe will shed light on genetic contributions to cancer (see page 470). Eight cancer centres in France, the Netherlands, Spain, Austria and Britain have signed up to the scheme, although some centres have refused to take part. "Scientists are not easily separated from their materials," Oosterhuis says, "but we argue that by making it available to others you get access to many more samples than you can ever collect yourself." The move comes as some researchers express concern that the existing network of tissue banks cannot meet the growing demand for materials. "There has been a huge expansion of molecular analysis on the basis of the genome and we need to provide the materials for this tissue analysis to be done," says Mike Stratton, who heads the Cancer Genome Project at Britain's Sanger Centre near Cambridge. Some countries, such as the United States and Spain, already link the contents of local banks into a national network. Others are setting up centralized national facilities for tumour tissue. In Britain, a generic tumour-tissue bank that will ultimately contain some 3,000 samples from 23 different cancers is expected to open at the University of Glasgow by the end of this year.
16 February 2024 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Re-irradiation of recurrent head and neck cancer (HNC) is often limited by tumour adherence to critical structures and/or radiation tolerance of critical normal tissues. Iopofosine I 131 (CLR 131) is a targeted small molecular phospholipid ether (PLE) drug conjugate that delivers iodine-131 selectively to tumour cells. We conducted a phase 1, single-centre, open-label study to determine whether CLR 131 given with reduced dose of external beam radiation therapy (EBRT) would be tolerable and feasible. All participants received previous curative intent treatment with radiotherapy as primary or adjuvant treatment. Eligible participants demonstrated uptake of CLR 131 as indicated via single photon emission CT/CT (SPECT/CT) imaging following CLR 131 test dose. Participants received two therapeutic doses of CLR 131 (days 1 and 8) with SPECT/CT imaging performed to quantitate the biodistribution of CLR 131. Participants subsequently received EBRT to achieve the designated radiation dose (60-70 Gy). The primary endpoint was safety. This trial was registered with ClinicalTrials.gov, NCT04105543, and enrolment and follow-up are complete. Twelve participants completed treatment with CLR 131 and EBRT. Eight participants experienced grade 4 non-DLT haematologic toxicities (2 anaemia, 8 leukopenia, 5 thrombocytopenia) at least probably attributed to CLR 131, consistent with the expected toxicity profile. Haematologic toxicities occurred during weeks 6-8 from the first dose of CLR 131 and resolved within three weeks without sequelae. There were no treatment-related grade 3-4 non-haematologic toxicities. CLR 131 in combination with EBRT did not confer any safety concerns, and was tolerable in participants with recurrent/metastatic HNC. Myelosuppression was consistent with the known toxicity profile of CLR 131. National Institutes of HealthP50 DE026787, National Cancer InstituteP30 CA014520, National Institutes of Health1UL1TR002373, Cellectar, NCT04105543.