Marcus Maeder

Marcus Maeder

Auto-generated profile, based on publicly available information

Marcus Maeder

Technical University of Munich

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2017 in Journal of Computational Acoustics
Verified
Journal Article
Open access
PDF file
PLP. Langer
P. Langer
MMM. Maeder
M. Maeder
CGC. Guist
C. Guist
MKM. Krause
M. Krause
SMS. Marburg
S. Marburg
Choosing the right number and type of elements in modern commercial finite element tools is a challenging task. It requires a broad knowledge about the theory behind or much experience by the user. Benchmark tests are a common method to prove the element performance against analytical solutions. However, these tests often analyze the performance only for single elements. When investigating the complete mesh of an arbitrary structure, the comparison of the element’s performance is quite challenging due to the lack of closed or fully converged solutions. The purpose of this paper is to show a high-precision comparison of eigenfrequencies of a real structure between experimental and numerical results in the context of an element performance check with respect to a converged solution. Additionally, the authors identify the practically relevant accuracy of simulation and experiment. Finally, the influence of accuracy with respect to the number of elements per standing structural bending wave is shown.

1 March 2020 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
AMAnton Melnikov
Anton Melnikov
MMMarcus Maeder
Marcus Maeder
NFNiklas Friedrich
Niklas Friedrich
YPYan Pozhanka
Yan Pozhanka
AWAlexander Wollmann
Alexander Wollmann
SMSteffen Marburg
Steffen Marburg
Noise mitigation of stage machinery can be quite demanding and requires innovative solutions. In this work, an acoustic metamaterial capsule is proposed to reduce the noise emission of several stage machinery drive trains, while still allowing the ventilation required for cooling. The metamaterial capsule consists of c-shape meta-atoms, which have a simple structure that facilitates manufacturing. Two different metamaterial capsules are designed, simulated, manufactured, and experimentally validated that utilize an ultra-sparse and air-permeable reflective meta-grating. Both designs demonstrate transmission loss peaks that effectively suppress gear mesh noise or other narrow band noise sources. The ventilation by natural convection was numerically verified, and was shown to give adequate cooling, whereas a conventional sound capsule would lead to overheating. The noise spectra of three common stage machinery drive trains are numerically modelled, enabling one to design meta-gratings and determine their noise suppression performance. The results fulfill the stringent stage machinery noise limits, highlighting the benefit of using metamaterial capsules of simple c-shape structure.

27 October 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
FKFelix Kronowetter
Felix Kronowetter
MMMarcus Maeder
Marcus Maeder
YCYan Kei Chiang
Yan Kei Chiang
LHLujun Huang
Lujun Huang
JSJohannes D. Schmid
Johannes D. Schmid
SMSteffen Marburg
Steffen Marburg
Quasi-bound states in the continuum (QBICs) coupling into the propagating spectrum manifest themselves as high-quality factor (Q) modes susceptible to perturbations. This poses a challenge in predicting stable Fano resonances for realistic applications. Besides, where and when the maximum field enhancement occurs in real acoustic devices remains elusive. In this work, we theoretically predict and experimentally demonstrate the existence of a Friedrich-Wintgen BIC in an open acoustic cavity. We provide direct evidence for a QBIC by mapping the pressure field inside the cavity using a Laser Doppler Vibrometer (LDV), which provides the missing field enhancement data. Furthermore, we design a symmetry-reduced BIC and achieve field enhancement by a factor of about three compared to the original cavity. LDV measurements are a promising technique for obtaining high-Q modes’ missing field enhancement data. The presented results facilitate the future applications of BICs in acoustics as high-intensity sound sources, filters, and sensors.

30 November 2022 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
SCS. Chandra
S. Chandra
MMM. Maeder
M. Maeder
JBJ. Bienert
J. Bienert
HBH. Beinersdorf
H. Beinersdorf
WJW. Jiang
W. Jiang
SMS. Marburg
S. Marburg

15 August 2024 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
MKMariia Krasikova
Mariia Krasikova
FKFelix Kronowetter
Felix Kronowetter
SKSergey Krasikov
Sergey Krasikov
MKMikhail Kuzmin
Mikhail Kuzmin
MMMarcus Maeder
Marcus Maeder
ABAndrey Bogdanov
Andrey Bogdanov
Resonant states underpin a variety of metastructures that exhibit remarkable capabilities for the effective control of acoustic waves at subwavelength scales. The development of metamaterials relies on rigorous mode engineering, providing the implementation of the desired properties. At the same time, the application of metamaterials is still limited, as their building blocks are frequently characterized by complicated geometry and cannot be tuned easily. In this work, we consider a simple system of coupled Helmholtz resonators and study their properties associated with the tuning of coupling strength and symmetry breaking. We numerically and experimentally demonstrate the excitation of the quasibound state in the continuum in the resonators placed in free space and in a rectangular cavity. It is also shown that tuning the intrinsic losses via introducing porous inserts can lead to spectral splitting or merging of quasibound states in the continuum and the occurrence of exceptional points. The obtained results open opportunities for the development of simple and easily tunable metastructures based on Helmholtz resonances.

24 December 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
DWDominik Weidlich
Dominik Weidlich
MZMark Zamskiy
Mark Zamskiy
MMMarcus Maeder
Marcus Maeder
SRStefan Ruschke
Stefan Ruschke
SMSteffen Marburg
Steffen Marburg
DKDimitrios Karampinos
Dimitrios Karampinos
Purpose: Diffusion encoding gradients are known to yield vibrations of the typical clinical MR scanner hardware with a frequency of 20 to 30 Hz, which may lead to signal loss in diffusion‐weighted MR measurements. This work proposes to mitigate vibration‐induced signal loss by introducing a vibration‐matching gradient (VMG) to match vibrational states during the 2 diffusion gradient pulses.Theory and Methods: A theoretical description of displacements induced by gradient switching was introduced and modeled by a 2‐mass‐spring‐damper system. An additional preceding VMG mimicking timing and properties of the diffusion encoding gradients was added to a high b‐value diffusion‐weighted MR spectroscopy sequence. Laser interferometry was employed to measure 3D displacements of a phantom surface. Lipid ADC was assessed in water–fat phantoms and in vivo in the tibial bone marrow of 3 volunteers.Results: The modeling and the laser interferometer measurements revealed that the displacement curves are more similar during the 2 diffusion gradients with the VMG compared to the standard sequence, resulting in less signal loss of the diffusion‐weighted signal. Phantom results showed lipid ADC overestimation up to 119% with the standard sequence and an error of 5.5% with the VMG. An 18% to 35% lower coefficient of variation was obtained for in vivo lipid ADC measurement when employing the VMG.Conclusion: The application of the VMG reduces the signal loss introduced by hardware vibrations in a high b‐value diffusion‐weighted MRS sequence in phantoms and in vivo. Reference measurements based on laser interferometry and mechanical modelling confirmed the findings.