Marco Tardocchi

Marco Tardocchi

Auto-generated profile, based on publicly available information

Marco Tardocchi

Istitute for Plasma Science and Technology ISTP, CNR, Milan, Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2023 in Measurement Science and Technology
Verified
Journal Article
Open access
AMA Dal Molin
A Dal Molin
Massimo NocenteMassimo Nocente
Massimo Nocente
MRM Dalla Rosa
M Dalla Rosa
EPE Panontin
E Panontin
DRD Rigamonti
D Rigamonti
VKV Kiptily
V Kiptily
Runaway electron gamma-ray detection system, a novel hard x-ray (HXR) spectrometer optimized for bremsstrahlung radiation measurement from runaway electrons in fusion plasmas, has been developed. The detector is based on a 1‘×1’ LaBr3:Ce scintillator crystal coupled with a photomultiplier tube. The system has an energy dynamic range exceeding 20 MeV with an energy resolution of 3% at 661.7 keV. The detector gain is stable even under severe loads, with a gain shift that stays below 3% at HXR counting rates in excess of 1 MCps. The performance of the system enables unprecedented studies of the time-dependent runaway electron energy distribution function, as shown in recent runaway electron physics experiments at the ASDEX Upgrade and COMPASS tokamaks.

1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
AMA. Dal Molin
A. Dal Molin
LFL. Fumagalli
L. Fumagalli
Massimo NocenteMassimo Nocente
Massimo Nocente
DRD. Rigamonti
D. Rigamonti
MTM. Tardocchi
M. Tardocchi
Giuseppe GoriniGiuseppe Gorini
Giuseppe Gorini
A novel compact spectrometer optimized for the measurement of hard x rays generated by runaway electrons is presented. The detector is designed to be installed in the fan-shaped collimator of the gamma-ray imager diagnostic at the DIII-D tokamak. The spectrometer is based on a 1 × 1 cm2 cerium doped yttrium aluminum perovskite scintillator crystal coupled with a silicon photomultiplier. The detector dynamic energy range is in excess of 10 MeV, with an energy resolution of ∼10% at 661.7 keV. The fast detector signal (≈70 ns full width at half maximum) allows for operation at counting rates in excess of 1 MCps. The gain stability of the system can be monitored in real time using a light-emitting diode embedded in the instrument. The detector is expected to be deployed in the forthcoming DIII-D runaway electron experimental campaign.

1 November 2017 in Fusion Engineering and Design
Verified
Journal Article
Closed access
GBG. Boltruczyk
G. Boltruczyk
ABAndrzej Broslawski
Andrzej Broslawski
MGM. Gosk
M. Gosk
SKS. Korolczuk
S. Korolczuk
RKR. Kwiatkowski
R. Kwiatkowski
IZI. Zychor
I. Zychor

1 December 2018 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SFS. Feng
S. Feng
CCCarlo Cazzaniga
Carlo Cazzaniga
TMTriestino Minniti
Triestino Minniti
Massimo NocenteMassimo Nocente
Massimo Nocente
CFC. Frost
C. Frost
MTM. Tardocchi
M. Tardocchi

28 July 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SCStefano Colombi
Stefano Colombi
MRMarica Rebai
Marica Rebai
GMGiovanni Mariano
Giovanni Mariano
BCBruno Coriton
Bruno Coriton
GMGiulia Marcer
Giulia Marcer
MTMarco Tardocchi
Marco Tardocchi
The ITER Radial Gamma Ray Spectrometer (RGRS) is a high-performance diagnostic instrument designed to measure gamma radiation emitted by the plasma in the ITER tokamak fusion reactor. RGRS will have three dedicated radial lines of sight plus one shared with the Radial Neutron Camera, and uses LaBr3 scintillator detectors to record gamma-ray spectra for the study of fast ions, the monitoring of runaway electrons, and the measurement of fusion power. A critical challenge in the operation of RGRS will be the characterisation of the gamma-ray background reaching the detectors, which is required to improve diagnostic design, correctly interpret detector spectra and assess diagnostic performance. This work presents MCNP Monte Carlo simulations of the gamma-ray background in RGRS, employing a two-step simulation approach to isolate and quantify the dominant background contributions. Results indicate that neutron-induced gamma-rays from the central column will be the primary background source, exceeding by nearly one order of magnitude all other contributions along the line of sight, with direct implications for the detector count rate and the signal-to-background ratio during full-power ITER operation.

3 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SCStefano Colombi
Stefano Colombi
MRMarica Rebai
Marica Rebai
DRDavide Rigamonti
Davide Rigamonti
GMGiulia Marcer
Giulia Marcer
ECEnrico Perelli Cippo
Enrico Perelli Cippo
MTMarco Tardocchi
Marco Tardocchi
The gamma rays emitted by the T(D,γ)5He fusion reaction have been measured at the FNG neutron irradiation facility in ENEA-Frascati by using a large 3”x3” LaBr3 scintillator crystal. Since the gamma ray emission probability by the DT reaction is 10-5 lower with respect to the main fusion reaction channel T(D,n)4He a neutron attenuator is needed. In this paper we present the design of a neutron attenuator based on a combination of different materials. The neutron attenuator performances have been studied with a series of MCNP simulations benchmarked with an experiment performed with a 137Cs gamma ray source. The analysis of the experimental results shows a gamma component in the region of interest that is compatible with the T(D,γ)5He reaction. Although the results obtained at FNG indicate that the gamma rays emitted by the T(D,γ)5He can be measured with the present set-up, they also show that an improvement of the experimental set-up is needed. An analysis of the background induced by the scattered neutrons is provided and improvements to the neutron attenuator are proposed.