Ivan V. Ganyukov

Ivan V. Ganyukov

Auto-generated profile, based on publicly available information

Ivan V. Ganyukov

Federal State Budgetary Institution “Research Institute for Complex Issues of Cardiovascular Diseases

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2024 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
ВГВладимир Ганюков
Владимир Ганюков
Roman S. TarasovRoman S. Tarasov
Roman S. Tarasov
АКАлексей Юрьевич Колесников
Алексей Юрьевич Колесников
IGIvan V. Ganyukov
Ivan V. Ganyukov
HighlightsTranscatheter aortic valve replacement is an innovative trend in modern cardiovascular surgery. This minimally invasive image-guided endovascular technology is becoming more and more safe, nowadays it can involve a minimalistic approach in which the aortic valve replacement is performed without incisions, anesthesia and cardiopulmonary bypass - patients are conscious and spontaneously breathing. The article describes a paradigm shift in modern cardiology, in which the concept of treating patients with degenerative aortic valve stenosis has changed over the 20 years of existence of the transcatheter replacement, starting as a method used only in small number of extremely high-risk patients unsuitable for cardiac surgery and now being the most prevalent treatment modality in patients at intermediate and even low surgical risk. The main clinical and technical principles of transcatheter aortic valve replacement, as well as the prospects for the development of this technique, are highlighted. Abstract Transcatheter aortic valve replacement technique was first implemented about 20 years ago, in April 2002. A quarter of a century ago, specialists involved in image-guided surgery would have never believed that they would perform transcatheter interventions on heart valves. Transcatheter interventions are an alternative to open-heart surgery for acquired heart disease. Transcatheter heart valve replacement or repeat transcatheter aortic valve replacement, which do not require incisions, cardiopulmonary bypass, and in some cases general anesthesia, to this day continue to be perceived as revolutionary and breakthrough, saving the lives of many patients. The article presents the main milestones in the development of image-guided endovascular surgery and transcatheter aortic valve replacement technique, the number of which in the United States and several European countries increases by 10–15% annually, reaching hundreds of thousands per year. The etiology and pathophysiology of aortic stenosis, the technique of transcatheter aortic valve replacement and the outcome of this promising minimally invasive procedure are presented.

7 April 2020 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
ВГВладимир Ганюков
Владимир Ганюков
ESE. Shloido
E. Shloido
Roman S. TarasovRoman S. Tarasov
Roman S. Tarasov
НРН. В. Рогулина
Н. В. Рогулина
IKI. Khalivopulo
I. Khalivopulo
ИГИ. В. Ганюков
И. В. Ганюков
A clinical case of endovascular correction of a biological mitral valve prosthesis dysfunction by implantation of a transcatheter aortic valve into the mitral position is described. Considering the clinical status of the patient, the condition was determined to be inoperable. Subsequently, based on vital fluoroscopy and echocardiography findings, the patient was implanted with a transcatheter aortic valve in the mitral valve bioprosthesis position. The technical and clinical aspects of the intervention and its results were analysed during the hospital period and for 5 months after implantation. The selected method of treatment was found to be appropriate.Received 10 January 2020. Revised 18 March 2020. Accepted 19 March 2020.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.Author contributionsDrafting the article: N.V. Rogulina, I.V. Ganyukov, A.M. Kochergina, V.I. Ganyukov, R.S. Tarasov, I.K. Khalivopulo, I.N. Sizova Literature review: V.I. Ganyukov, R.S. Tarasov, N.V. Rogulina, I.K. Khalivopulo, I.V. Ganyukov, A.M. Kochergina Illustrations: I.V. Ganyukov, I.N. Sizova, N.V. Rogulina Critical revision of the article: V.I. Ganyukov, R.S. Tarasov, E.A. Shloido, L.S. Barbarash Surgical treatment: E.A. Shloido, V.I. Ganyukov, R.S. TarasovFinal approval of the version to be published: V.I. Ganyukov, E.A. Shloido, R.S. Tarasov, N.V. Rogulina, I.K. Khalivopulo, I.V. Ganyukov, A.M. Kochergina, I.N. Sizova, L.S. Barbarash

4 February 2023 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
POP. S. Onishchenko
P. S. Onishchenko
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
VGV. I. Ganyukov
V. I. Ganyukov
ASA. A. Shilov
A. A. Shilov
LBLeonid Barbarash
Leonid Barbarash
Highlights. Using ECHO and MSCT data, a numerical assessment of hemodynamic effects of paraprosthetic regurgitation following transcatheter aortic valve replacement was performed. A significant increase in the fluid flow, wall and viscous shear stresses in the area of regurgitation is shown. The modeling technique described in the paper can be used prospectively in assessing the optimal treatment modality in terms of predicting the quantitative characteristics of the flow, associated with the risks of destruction of red blood cells and thrombosisAim. To make a numerical assessment of hemodynamic effects of paraprosthetic regurgitation following transcatheter aortic valve replacement based on retrospective clinical data.Methods. The study included echocardiography and multi-slice computed tomography data as input data for modeling one pulsation of a fluid similar in properties to blood. Reconstruction of the paraprosthetic fistula and the ascending aorta was performed in the Mimics medium (Materialise, Belgium). The obtained 3D models were processed in the Salome software (OPEN CASCADE SAS, France), after which they were exported to HELYX-OS (ENGYS, Great Britain) to build a finite element mesh. The flows were modeled using the OpenFOAM software package version 6 (The OpenFOAM Foundation Ltd, UK).Results. The simulation result, expressed quantitatively and qualitatively in the form of diagrams of the measured parameters – fluid flow velocities, wall and viscous shear stresses, shows a significant increase in indicators in the area of paraprosthetic regurgitation. Thus, the velocity in the affected area was 1.9–4.2 m/s, which is 3.8 higher than the average value in the entire computational area. The wall shear stress value was up to 61 Pa in the critical area, which may indicate an increased risk of thrombus formation due to the initiation of the clotting cascade through the von Willebrand factor. The value of viscous shear stress, the main component of the destruction of red blood cells in laminar flow, amounted to 20–26 Pa, which, in general, is not enough for mechanical hemolysis.Conclusion. The modeling technique described in the paper can be used prospectively in assessing the optimal treatment modality in terms of predicting the quantitative characteristics of the flow, associated with the risks of destruction of red blood cells and thrombosis.

31 October 2025 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
IGIvan V. Ganyukov
Ivan V. Ganyukov
IDIvan V. Dvadtsatov
Ivan V. Dvadtsatov
ИМИрина Николаевна Мамчур
Ирина Николаевна Мамчур
Roman S. TarasovRoman S. Tarasov
Roman S. Tarasov
ВГВладимир Ганюков
Владимир Ганюков
Highlights The study demonstrates the possibility of successful repeated endovascular intervention in case of dysfunction of a previously implanted bioprosthesis, which opens up new prospects in the treatment of patients with complications after aortic valve replacement. The study showed the high efficiency and safety of the method: technical success was achieved in all 8 cases, while no deaths, strokes or other serious complications were recorded during the 12 months of follow-up. The clinical effectiveness of the method is confirmed by the positive dynamics of EchoCG parameters (reduction of pressure gradient, disappearance of severe regurgitation, reduction of LV hypertrophy) and improvement of patients’ condition. Aim . To evaluate the safety and effectiveness of transcatheter prosthetics of the aortic valve (TPAK) using the valve-in-valve method in patients with bioprosthesis dysfunction in the aortic position based on the analysis of the results of the first endovascular reprosthetics procedures at the Scientific Research Institute of Complex Problems of Cardiovascular Diseases (NII KPSSZ). Methods . The present study included 8 patients with aortic bioprosthesis dysfunction who underwent valve-to-valve transfemoral access during this time period. Of the 8 valve-to-valve surgical procedures, 7 endovascular interventions were performed due to the development of dysfunctions of biological prostheses in the aortic position after open surgery and in 1 case after the primary surgical procedure. Average STS Score = 8.4%. The main types of dysfunction were primary tissue failure with rupture of xenospores and the formation of insufficiency (n = 5) and calcium degeneration of the biological valve with the appearance of a stenotic effect (n = 3). The endpoints were evaluated for efficiency and safety and were divided into 3 blocks: 1) Clinical results; 2) Complications; 3) EchoCG data. The results were evaluated 30 days after the intervention and after 12 months. Results . The average duration of aortic valve function after primary arthroplasty until the first signs of dysfunction was 5.3 (3.1; 11.9) years. After valve-to-valve TPA with transfemoral access, death from all causes, cardiovascular death, periprocedural death, stroke, TIA, myocardial infarction, vascular complications, cardiac complications, bleeding (on the BARC scale), arrhythmological events, prosthetic dysfunction requiring reoperative, infectious endocarditis were not noted not in any case. The technical success of TPAC, which was assessed only during the period of hospitalization, was noted in all cases. Only one patient (16.67%) was hospitalized for CHF decompensation at the 12-month follow-up stage with satisfactory indicators of aortic bioprosthesis function according to EchoCG. According to the EchoCG data between the period before reprosthetics and 12 months after, there was a significant positive trend in terms of maximum velocity and maximum gradient per AC. At the same time, the changes in the average velocity and average gradient were not significant. Grade III–IV transprosthetic regurgitation before reprosthetics was observed in 4 patients (50%), and in dynamics it disappeared (only grade I regurgitation or its complete absence is noted), as well as regurgitation on grade III–IV MK was observed in 5 patients (62.5%), and in dynamics it disappeared (regurgitation is noted only of I and II degrees). LV hypertrophy became less pronounced in dynamics (average myocardial mass index after TPAK = 109.5 g/m 2 ). Conclusion . After valve-to-valve TPA with transfemoral access performed at the KPSSZ Research Institute, favorable results were shown after 30 days and 12 months. The low number of intra- and postoperative complications, the positive dynamics of the clinical status of patients and structural and functional parameters assessed by EchoCG led to a positive conclusion on the safety and effectiveness of the presented method of treatment of patients with aortic bioprosthesis dysfunction.

4 May 2026 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
АДАрина Игоревна Данилович
Арина Игоревна Данилович
Roman S. TarasovRoman S. Tarasov
Roman S. Tarasov
IGIvan V. Ganyukov
Ivan V. Ganyukov
ВГВладимир Ганюков
Владимир Ганюков
Highlights Various methods of over-frequency ventricular stimulation in endovascular interventions on heart valves are analyzed. A new method of pacing using an over-stiff guidewire in the left ventricle and a coronary guidewire in the femoral artery is presented in transcatheter aortic valve replacement .   Absract The publication presents and substantiates the methodology of pacing in TIAC using an ultra-rigid conductor in the left ventricle and a coronary conductor in the femoral artery. A technique for ultra–frequent stimulation of the ventricles of the heart is described, in particular, the use of a coronary artery in the femoral artery, the approach is illustrated by a clinical example. The proposed method makes it possible to successfully perform transcatheter intervention on the aortic valve: it provides stable, ultra-frequent stimulation of the ventricles at small amplitudes, while it does not require additional manipulations, new accesses, special tools and additional material costs.

10 August 2026 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
Roman S. TarasovRoman S. Tarasov
Roman S. Tarasov
IGIvan V. Ganyukov
Ivan V. Ganyukov
ADArina I. Danilovich
Arina I. Danilovich
ВГВладимир Ганюков
Владимир Ганюков
Introduction: Given the annual increase in the need for repeated heart valve replacement, which is a high-risk surgical procedure due to repeated surgical access against the background of severe adhesions, trauma and comorbidity of patients, the technique of transcatheter heart valve replacement is becoming increasingly relevant and preferable. Objective: To present in detail modern methodologies for transcatheter mitral and tricuspid valve replacement using clinical examples. Methods: The presented patients had dysfunction of a previously openly implanted mitral/tricuspid bioprosthesis according to clinical data and echocardiography. Taking into account the high risk of surgical intervention, resternotomy and comorbid condition, after analyzing multispiral computed tomography within the framework of the cardiac team (cardiologist, endovascular surgeon, cardiovascular surgeon) it was decided to perform endovascular transcatheter repeat replacement using the "valve-in-valve" method. In both cases, puncture vascular access through the common femoral vein was used. Results: Balloon-expandable heart valve prostheses were effectively implanted in patients in the atrioventricular positions, achieving satisfactory hemodynamic parameters. Local anesthesia and transthoracic echocardiography were used for transcatheter tricuspid valve replacement. Mitral valve replacement was performed under total intravenous anesthesia, artificial ventilation, using transesophageal echocardiography, ultra-frequent cardiac pacing, and puncture of the interatrial septum. No complications were detected in the intra- and postoperative periods. The patients were discharged on the seventh day after the intervention. Conclusion: The methodology of transcatheter atrioventricular heart valve replacement is presented using clinical cases as an example, the effectiveness and safety of endovascular mitral and tricuspid valve replacement using balloon-expandable prostheses are shown. Further studies are needed that can provide a comparative assessment of the technologies of transcatheter and surgical atrioventricular heart valve replacement based on the analysis of long-term surgical results. Received 29 April 2025. Revised 28 January 2026. Accepted 3 February 2026. Informed consent The patient's informed consent to use the records for medical purposes is obtained. Funding The study was carried out with financial support from the Ministry of Science and Higher Education of the Russian Federation as part of the research project "Endovascular and extracorporeal technologies for the prevention and treatment of structural heart pathology and critical conditions in cardiac surgery" (No. 0419-2026-0004). Conflict of interest The authors declare no conflict of interest. Contribution of the authors Conception and study design: R.S. Tarasov, V.I. Ganyukov Data collection and analysis: I.V. Ganyukov, A.I. Danilovich Statistical analysis: I.V. Ganyukov, A.I. Danilovich Drafting the article: I.V. Ganyukov Critical revision of the article: R.S. Tarasov, V.I. Ganyukov Final approval of the version to be published: all authors