17 April 2018 in Measurement Science and Technology
Multi-camera vision systems are often needed to achieve large-scale and high-precision measurement because these systems have larger fields of view (FOV) than a single camera. Multiple cameras may have no or narrow overlapping FOVs in many applications, which pose a huge challenge to global calibration. This paper presents a global calibration method for multi-cameras without overlapping FOVs based on photogrammetry technology and a reconfigurable target. Firstly, two planar targets are fixed together and made into a long target according to the distance between the two cameras to be calibrated. The relative positions of the two planar targets can be obtained by photogrammetric methods and used as invariant constraints in global calibration. Then, the reprojection errors of target feature points in the two cameras’ coordinate systems are calculated at the same time and optimized by the Levenberg–Marquardt algorithm to find the optimal solution of the transformation matrix between the two cameras. Finally, all the camera coordinate systems are converted to the reference coordinate system in order to achieve global calibration. Experiments show that the proposed method has the advantages of high accuracy (the RMS error is 0.04 mm) and low cost and is especially suitable for on-site calibration.
15 December 2022 in Measurement
16 September 2021 in IEEE Transactions on Instrumentation and Measurement
Multicamera systems have important applications in industrial online measurement, attracting wide interest due to their encouraging performance. However, how to develop a convenient and high-accuracy multicamera calibration model is a big challenge. Traditional calibration methods based on 2-D objects require the preparation of high-precision and large-scale calibration objects and have poor adaptability to the spatial distribution of cameras. To address these issues, a convenient and accurate multicamera calibration method is proposed based on an imperfect spherical object. Specifically, a special calibration object, i.e., an imperfect sphere with many coded targets is designed for calibrating the multicamera system, where the optical axes of the cameras are different in orientations and converge into the measurement field. Then, a Euclidean reconstruction method is employed to calculate the camera poses and the spatial coordinates of feature points in the local coordinate system after the adaptive grouping of cameras is completed. Moreover, a graph theory-based optimal path transformation algorithm is developed to obtain the camera poses and spatial point coordinates in the global coordinate system (GCS), and a spherical projection optimization algorithm is designed to spheroidize the spatial coordinates of feature points. In the end, the camera poses and the spatial coordinates of feature points in the GCS are optimized by a bundle adjustment algorithm. We build a multicamera system and conduct extensive experiments to demonstrate the superiority of the proposed method.
21 October 2022 in Measurement Science and Technology
3D scanning is a crucial step to ensuring the machining quality of the workpiece and is an essential part of intelligent manufacturing. However, existing scanning systems usually have only one profiler, which must be combined with a dynamic tracking system to achieve a complete scan of a workpiece. This scanning method has low efficiency and complicated path planning for ring-shaped workpieces. Therefore, in this article, an efficient and high-accuracy 3D scanning system composed of a linear translation stage and four uniformly distributed laser profilers is built, and its extrinsic calibration method is studied. At first, based on the working parameters and spatial layout of multiple profilers, a stereoscopic calibrator composed of three non-collinear target balls (TBs) is designed. Then, a multi-profiler data fusion method is proposed, which utilizes a linear encoder to trigger the four profilers synchronously. Finally, by simultaneously using all data from the multiple profilers and the spherical constraint of each TB, all extrinsic parameters are accurately calibrated at the same time. Experimental results show that the average probing size error of the TB with a 38.1 mm diameter is stable at about 0.007 mm, and its extended uncertainty is about 0.100 mm (k = 2). In addition, standard cylinders and bend tubes are scanned. The results show that the proposed method can meet the high-accuracy calibration requirements of the tube-bending deformation detection system.
17 July 2021 in Mathematical Problems in Engineering
In the field of aviation and astronautics, large complex surface parts such as aircraft cabin cover are complex, varying in model, and produced in small batch. In order to reduce fixture cost and improve production efficiency, a variable multipoint and multi-DOF supporting fixture is designed. The coordinate system of the complex structure fixture is defined, and the kinematics of the multibody structures driven by air cylinders are modeled according to the topological principle. With the help of this data structure, fast and optimal search for clamping state can be realized. With the dichotomy method, the driving amount of the electric cylinder of the suction cups and the two rotation angles of two rotation axes at the end of the linkages are solved accurately. Based on the digital twin simulation method, the precise clamping motion of flexible fixture is calculated for an aircraft cockpit cover with a software developed by the authors in C++ language on the Visual studio platform. The distance between the clamping point and the surface was verified with a laser tracker. Finally, the practical experiment of a real cockpit cover clamping proves the practicability and effectiveness of the proposed method.