Zheng Zhong

Zheng Zhong

Auto-generated profile, based on publicly available information

Zheng Zhong

Hebei Key Laboratory of Power Transmission Equipment Security Defense North China Electric Power University Baoding People's Republic of China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2021 in High Voltage
Verified
Journal Article
Open access
PDF file
ZZZheng Zhong
Zheng Zhong
YCYuan Chen
Yuan Chen
YLYunpeng Liu
Yunpeng Liu
SHSizu Hou
Sizu Hou
JGJianghai Geng
Jianghai Geng
At present, observing the temperature rise of composite insulators is an effective method for the detection of decay‐like defects. However, ambient humidity will affect the temperature rise of composite insulators, which will cause problems in screening the decay‐like composite insulators. Therefore, it is urgent to study the temperature rise principle of decay‐like insulators and find out the influence mechanism of humidity on temperature rise. In this study, a four‐electrode system is designed to measure the surface current, volume current and interface current of the decay‐like short sample and the intact short sample under different humidity. Then the equivalent circuit models of short samples and the 500 kV full‐size decay‐like composite insulator are built to analyse the contribution rates of leakage conductance loss and polarisation loss to temperature rise. The results show that the contribution rates of the polarisation loss to the temperature rise of two samples are 35.8% and 23.6% in low humidity, while they are 98.3% and 64.4% in high humidity. For the full‐size decay‐like composite insulator, the contribution rates of polarisation loss to its temperature rise in high or low humidity are more than 99%. In addition, the proportion of polarisation loss increases at first and then decreases with the increase of the length of the decay‐like section. The conclusions of this study provide a theoretical basis for further understanding the corresponding relationship between decay‐like defects and temperature rise and improve the detection rate of decay‐like insulators.

10 February 2022 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
ZZZheng Zhong
Zheng Zhong
YCYuan Chen
Yuan Chen
SHSizu Hou
Sizu Hou
BWBowen Wang
Bowen Wang
YLYunpeng Liu
Yunpeng Liu
XZXu Zhang
Xu Zhang
Abnormal heating of composite insulators on ultra‐high voltage (UHV) transmission lines is widespread under high humidity and heat in southern China. The infrared imaging technology can be used of quickly and effectively detect insulators with abnormal heating and determine their defect types. However, it may cause misjudgement when the infrared images are not clear. A super‐resolution reconstruction method of infrared images of composite insulators with abnormal heating based on improved super‐resolution generative adversarial networks (SRGAN) is proposed in this paper, and the dense residual network in SRGAN is perfected by introducing the residual channel attention (ResCA). This method overcomes the problems that the resolution of images reconstructed by traditional methods is not significantly improved, and images are too smooth, and the edge details are easily lost. Compared with the traditional methods, the five reference‐free image quality evaluation indexes of the image reconstructed by the improved SRGAN are increased by −0.73% to 63.84%. Further the effectiveness and superiority of the improved SRGAN are verified by comparing the changes in the distribution of grey values of infrared images before and after reconstruction. Finally, the improved SRGAN is used to perform super‐resolution reconstruction of the low‐resolution infrared image examples.