1 January 2026 in Advances in Civil Engineering
The increasing demand for sustainable construction materials has prompted the utilisation of industrial by‐products such as coal ash (CA) in masonry units. This study investigates the mechanical performance and stress–strain behaviour of masonry prisms (MPs) and wall assemblages constructed with CA bricks, compared with those constructed with conventional clay (CC) and fly ash (FA) bricks. Experimental evaluation was carried out using three mortar mixes with cement–sand ratios of 1:3, 1:4.5 and 1:6 to examine the influence of mortar strength on masonry response. A total of 54 MPs and 81 wall elements were tested under uniaxial compression and flexural loading. Flexural behaviour was assessed under loading conditions parallel and perpendicular to the bed layer joint (BLJ) to capture the anisotropic characteristics of masonry. The results indicate that prisms constructed with CA bricks exhibited higher compressive strength and greater deformability than those constructed with CC brick masonry. The stress–strain response remained linear up to approximately one‐third of peak stress, followed by nonlinear behaviour leading to failure. The secant modulus of elasticity was found to range from 330 to 870 times the masonry’s compressive strength, with an optimal proportionality factor identified. Regression‐based analytical models were developed to establish relationships between masonry compressive strength and the strengths of constituent materials, showing good agreement with experimental observations and Eurocode‐based formulations. Flexural strength was significantly influenced by loading orientation, with higher values observed when loading was applied perpendicular to the bed joints. Additionally, an increase in slenderness ratio led to a reduction in compressive strength of wall elements. The findings demonstrate that CA bricks provide a viable and sustainable alternative to traditional masonry units, offering improved mechanical performance and ductility while contributing to waste utilisation and environmental conservation.
1 January 2026 in Advances in Civil Engineering
Finite loading contact, annular geometry, fracture‐process‐zone (FPZ) development, material anisotropy, contact length, and interaction between machine and specimen stiffness can affect indirect tensile‐strength measurements from Brazilian disc test (BDT) and Brazilian ring test (BRT). In this study, we develop a unified multiplicative correction framework that includes these effects in a common formulation for BDT and BRT configurations. The framework incorporates contact–geometry interaction, annular geometric degradation, an effective FPZ correction, anisotropy, contact‐length effects, and an effective machine–specimen compliance correction. The model was calibrated with 72 specimens of light gray granite (LGG) and white marble (WM) tested at three different annularity levels, η = 0, 0.29/0.30, and 0.40. We carried out finite element simulations for the six configurations studied to assess the consistency of the corrected response with the calculated stress state. The results demonstrate a systematic decrease in the classical indirect tensile strength estimate following the proposed corrections, and the relative contribution of individual factors depends on specimen geometry and material response. The framework offers a geometry‐dependent formulation to compare Brazilian disc and ring configurations and explicitly defines the effective nature and limits of calibration for the correction parameters. Before generalizing, further validation with independently measured contact evolution, direct FPZ characterization, alternative machine stiffnesses, and independent datasets is needed.