Eunsung Cho

Eunsung Cho

Auto-generated profile, based on publicly available information

Eunsung Cho

Asleep Research Institute, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2023 in Journal of Medical Internet Research
Verified
Journal Article
Open access
VLVu Linh Le
Vu Linh Le
DKDaewoo Kim
Daewoo Kim
ECEunsung Cho
Eunsung Cho
HJHyeryung Jang
Hyeryung Jang
RRRoben Delos Reyes
Roben Delos Reyes
JKJeong-Whun Kim
Jeong-Whun Kim
Background: Multinight monitoring can be helpful for the diagnosis and management of obstructive sleep apnea (OSA). For this purpose, it is necessary to be able to detect OSA in real time in a noisy home environment. Sound-based OSA assessment holds great potential since it can be integrated with smartphones to provide full noncontact monitoring of OSA at home. Objective: The purpose of this study is to develop a predictive model that can detect OSA in real time, even in a home environment where various noises exist. Methods: This study included 1018 polysomnography (PSG) audio data sets, 297 smartphone audio data sets synced with PSG, and a home noise data set containing 22,500 noises to train the model to predict breathing events, such as apneas and hypopneas, based on breathing sounds that occur during sleep. The whole breathing sound of each night was divided into 30-second epochs and labeled as “apnea,” “hypopnea,” or “no-event,” and the home noises were used to make the model robust to a noisy home environment. The performance of the prediction model was assessed using epoch-by-epoch prediction accuracy and OSA severity classification based on the apnea-hypopnea index (AHI). Results: Epoch-by-epoch OSA event detection showed an accuracy of 86% and a macro F1-score of 0.75 for the 3-class OSA event detection task. The model had an accuracy of 92% for “no-event,” 84% for “apnea,” and 51% for “hypopnea.” Most misclassifications were made for “hypopnea,” with 15% and 34% of “hypopnea” being wrongly predicted as “apnea” and “no-event,” respectively. The sensitivity and specificity of the OSA severity classification (AHI≥15) were 0.85 and 0.84, respectively. Conclusions: Our study presents a real-time epoch-by-epoch OSA detector that works in a variety of noisy home environments. Based on this, additional research is needed to verify the usefulness of various multinight monitoring and real-time diagnostic technologies in the home environment.

1 March 2025 in Nature and Science of Sleep
Verified
Journal Article
Open access
PDF file
JHJoonki Hong
Joonki Hong
SYSeung Koo Yang
Seung Koo Yang
SKSeunghun Kim
Seunghun Kim
SCSung-Woo Cho
Sung-Woo Cho
JOJayoung Oh
Jayoung Oh
JKJeong-Whun Kim
Jeong-Whun Kim
Background: Despite the prevalence of sleep-related disorders, few studies have developed deep learning models to predict snoring using home-recorded smartphone audio. This study proposes a real-time snoring detection method utilizing a Vision Transformer-based deep learning model and smartphone recordings. Methods: Participants’ sleep-breathing sounds were recorded using smartphones, with concurrent Level I or II polysomnography (PSG) conducted in home or hospital settings. A total of 200 minutes of smartphone audio per participant, corresponding to 400 30-second sleep stage epochs on PSG, were sampled. Each epoch was annotated independently by two trained labelers, with snoring labeled only when both agreed. Model performance was evaluated by epoch-by-epoch prediction accuracy and correlation between observed and predicted snoring ratios. Results: The study included 214 participants (85,600 epochs). Hospital audio data from 105 participants (42,000 epochs) were used for training, while home audio data from 109 participants were split into 54 participants (21,600 epochs) for training and 55 participants (22,000 epochs) for testing. On the test dataset, the model demonstrated a sensitivity of 89.8% and a specificity of 91.3%. Correlation analysis showed strong agreement between observed and predicted snoring ratios (r = 0.97, 95% CI: 0.95– 0.99). Conclusion: This study demonstrates the feasibility of using deep learning for real-time snoring detection from home-recorded smartphone audio. With high accuracy and scalability, the approach offers a practical and accessible tool for monitoring sleep-related disorders, paving the way for home-based sleep health management solutions.

5 December 2022 in JMIR Preprints
Verified
Preprint
Open access
VLVu Linh Le
Vu Linh Le
DKDaewoo Kim
Daewoo Kim
ECEunsung Cho
Eunsung Cho
HJHyeryung Jang
Hyeryung Jang
RRRoben Delos Reyes
Roben Delos Reyes
JKJeong-Whun Kim
Jeong-Whun Kim
BACKGROUND Multinight monitoring can be helpful for the diagnosis and management of obstructive sleep apnea (OSA). For this purpose, it is necessary to be able to detect OSA in real time in a noisy home environment. Sound-based OSA assessment holds great potential since it can be integrated with smartphones to provide full noncontact monitoring of OSA at home. OBJECTIVE The purpose of this study is to develop a predictive model that can detect OSA in real time, even in a home environment where various noises exist. METHODS This study included 1018 polysomnography (PSG) audio data sets, 297 smartphone audio data sets synced with PSG, and a home noise data set containing 22,500 noises to train the model to predict breathing events, such as apneas and hypopneas, based on breathing sounds that occur during sleep. The whole breathing sound of each night was divided into 30-second epochs and labeled as “apnea,” “hypopnea,” or “no-event,” and the home noises were used to make the model robust to a noisy home environment. The performance of the prediction model was assessed using epoch-by-epoch prediction accuracy and OSA severity classification based on the apnea-hypopnea index (AHI). RESULTS Epoch-by-epoch OSA event detection showed an accuracy of 86% and a macro F1-score of 0.75 for the 3-class OSA event detection task. The model had an accuracy of 92% for “no-event,” 84% for “apnea,” and 51% for “hypopnea.” Most misclassifications were made for “hypopnea,” with 15% and 34% of “hypopnea” being wrongly predicted as “apnea” and “no-event,” respectively. The sensitivity and specificity of the OSA severity classification (AHI≥15) were 0.85 and 0.84, respectively. CONCLUSIONS Our study presents a real-time epoch-by-epoch OSA detector that works in a variety of noisy home environments. Based on this, additional research is needed to verify the usefulness of various multinight monitoring and real-time diagnostic technologies in the home environment.

30 April 2023 in The Korean Jornal of History of Science
Verified
Journal Article
Closed access
ECEunsung Cho
Eunsung Cho
학술논문검색사이트 KISS는 학술논문,연구논문,연구자료,학술지 등 다양한 자료를 서비스하며, 주제별, 등재별, 인용지수, 인기논문, 이슈논문 등 다양한 키워드의 논문을 제공하여 빠른 학술검색 및 인용이 가능하도록 서비스합니다.