Joonki Hong

Dr. Joonki Hong

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Applied Energy
Verified
Journal Article
Closed access
JHJoonki Hong
Joonki Hong
DLDongheon Lee
Dongheon Lee
EJEui-Rim Jeong
Eui-Rim Jeong
YYYung Yi
Yung Yi

2 November 2023 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
TLTaeyoung Lee
Taeyoung Lee
YCYounghoon Cho
Younghoon Cho
KCKwang Su Cha
Kwang Su Cha
JJJinhwan Jung
Jinhwan Jung
JCJungim Cho
Jungim Cho
JKJeong-Whun Kim
Jeong-Whun Kim
Background: Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. Objective: This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. Methods: The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. Results: The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. Conclusions: Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.

6 June 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
Soonil KwonSoonil Kwon
Soonil Kwon
JHJoonki Hong
Joonki Hong
ECEue-Keun Choi
Eue-Keun Choi
ELEuijae Lee
Euijae Lee
DHDavid Earl Hostallero
David Earl Hostallero
YYYung Yi
Yung Yi
Background: Wearable devices have evolved as screening tools for atrial fibrillation (AF). A photoplethysmographic (PPG) AF detection algorithm was developed and applied to a convenient smartphone-based device with good accuracy. However, patients with paroxysmal AF frequently exhibit premature atrial complexes (PACs), which result in poor unmanned AF detection, mainly because of rule-based or handcrafted machine learning techniques that are limited in terms of diagnostic accuracy and reliability. Objective: This study aimed to develop deep learning (DL) classifiers using PPG data to detect AF from the sinus rhythm (SR) in the presence of PACs after successful cardioversion. Methods: We examined 75 patients with AF who underwent successful elective direct-current cardioversion (DCC). Electrocardiogram and pulse oximetry data over a 15-min period were obtained before and after DCC and labeled as AF or SR. A 1-dimensional convolutional neural network (1D-CNN) and recurrent neural network (RNN) were chosen as the 2 DL architectures. The PAC indicator estimated the burden of PACs on the PPG dataset. We defined a metric called the confidence level (CL) of AF or SR diagnosis and compared the CLs of true and false diagnoses. We also compared the diagnostic performance of 1D-CNN and RNN with previously developed AF detectors (support vector machine with root-mean-square of successive difference of RR intervals and Shannon entropy, autocorrelation, and ensemble by combining 2 previous methods) using 10 5-fold cross-validation processes. Results: Among the 14,298 training samples containing PPG data, 7157 samples were obtained during the post-DCC period. The PAC indicator estimated 29.79% (2132/7157) of post-DCC samples had PACs. The diagnostic accuracy of AF versus SR was 99.32% (70,925/71,410) versus 95.85% (68,602/71,570) in 1D-CNN and 98.27% (70,176/71,410) versus 96.04% (68,736/71,570) in RNN methods. The area under receiver operating characteristic curves of the 2 DL classifiers was 0.998 (95% CI 0.995-1.000) for 1D-CNN and 0.996 (95% CI 0.993-0.998) for RNN, which were significantly higher than other AF detectors (P<.001). If we assumed that the dataset could emulate a sufficient number of patients in training, both DL classifiers improved their diagnostic performances even further especially for the samples with a high burden of PACs. The average CLs for true versus false classification were 98.56% versus 78.75% for 1D-CNN and 98.37% versus 82.57% for RNN (P<.001 for all cases). Conclusions: New DL classifiers could detect AF using PPG monitoring signals with high diagnostic accuracy even with frequent PACs and could outperform previously developed AF detectors. Although diagnostic performance decreased as the burden of PACs increased, performance improved when samples from more patients were trained. Moreover, the reliability of the diagnosis could be indicated by the CL. Wearable devices sensing PPG signals with DL classifiers should be validated as tools to screen for AF.

21 May 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
Soonil KwonSoonil Kwon
Soonil Kwon
JHJoonki Hong
Joonki Hong
ECEue-Keun Choi
Eue-Keun Choi
BLByunghwan Lee
Byunghwan Lee
CBChanghyun Baik
Changhyun Baik
YYYung Yi
Yung Yi
Background: Continuous photoplethysmography (PPG) monitoring with a wearable device may aid the early detection of atrial fibrillation (AF). Objective: We aimed to evaluate the diagnostic performance of a ring-type wearable device (CardioTracker, CART), which can detect AF using deep learning analysis of PPG signals. Methods: Patients with persistent AF who underwent cardioversion were recruited prospectively. We recorded PPG signals at the finger with CART and a conventional pulse oximeter before and after cardioversion over a period of 15 min (each instrument). Cardiologists validated the PPG rhythms with simultaneous single-lead electrocardiography. The PPG data were transmitted to a smartphone wirelessly and analyzed with a deep learning algorithm. We also validated the deep learning algorithm in 20 healthy subjects with sinus rhythm (SR). Results: In 100 study participants, CART generated a total of 13,038 30-s PPG samples (5850 for SR and 7188 for AF). Using the deep learning algorithm, the diagnostic accuracy, sensitivity, specificity, positive-predictive value, and negative-predictive value were 96.9%, 99.0%, 94.3%, 95.6%, and 98.7%, respectively. Although the diagnostic accuracy decreased with shorter sample lengths, the accuracy was maintained at 94.7% with 10-s measurements. For SR, the specificity decreased with higher variability of peak-to-peak intervals. However, for AF, CART maintained consistent sensitivity regardless of variability. Pulse rates had a lower impact on sensitivity than on specificity. The performance of CART was comparable to that of the conventional device when using a proper threshold. External validation showed that 94.99% (16,529/17,400) of the PPG samples from the control group were correctly identified with SR. Conclusions: A ring-type wearable device with deep learning analysis of PPG signals could accurately diagnose AF without relying on electrocardiography. With this device, continuous monitoring for AF may be promising in high-risk populations. Trial Registration: ClinicalTrials.gov NCT04023188; https://clinicaltrials.gov/ct2/show/NCT04023188

22 February 2023 in Journal of Medical Internet Research
Verified
Journal Article
Open access
VLVu Linh Le
Vu Linh Le
DKDaewoo Kim
Daewoo Kim
ECEunsung Cho
Eunsung Cho
HJHyeryung Jang
Hyeryung Jang
RRRoben Delos Reyes
Roben Delos Reyes
JKJeong-Whun Kim
Jeong-Whun Kim
Background: Multinight monitoring can be helpful for the diagnosis and management of obstructive sleep apnea (OSA). For this purpose, it is necessary to be able to detect OSA in real time in a noisy home environment. Sound-based OSA assessment holds great potential since it can be integrated with smartphones to provide full noncontact monitoring of OSA at home. Objective: The purpose of this study is to develop a predictive model that can detect OSA in real time, even in a home environment where various noises exist. Methods: This study included 1018 polysomnography (PSG) audio data sets, 297 smartphone audio data sets synced with PSG, and a home noise data set containing 22,500 noises to train the model to predict breathing events, such as apneas and hypopneas, based on breathing sounds that occur during sleep. The whole breathing sound of each night was divided into 30-second epochs and labeled as “apnea,” “hypopnea,” or “no-event,” and the home noises were used to make the model robust to a noisy home environment. The performance of the prediction model was assessed using epoch-by-epoch prediction accuracy and OSA severity classification based on the apnea-hypopnea index (AHI). Results: Epoch-by-epoch OSA event detection showed an accuracy of 86% and a macro F1-score of 0.75 for the 3-class OSA event detection task. The model had an accuracy of 92% for “no-event,” 84% for “apnea,” and 51% for “hypopnea.” Most misclassifications were made for “hypopnea,” with 15% and 34% of “hypopnea” being wrongly predicted as “apnea” and “no-event,” respectively. The sensitivity and specificity of the OSA severity classification (AHI≥15) were 0.85 and 0.84, respectively. Conclusions: Our study presents a real-time epoch-by-epoch OSA detector that works in a variety of noisy home environments. Based on this, additional research is needed to verify the usefulness of various multinight monitoring and real-time diagnostic technologies in the home environment.

1 June 2022 in Nature and Science of Sleep
Verified
Journal Article
Open access
PDF file
JHJoonki Hong
Joonki Hong
HTHai Hong Tran
Hai Hong Tran
JJJinhwan Jung
Jinhwan Jung
HJHyeryung Jang
Hyeryung Jang
DLDongheon Lee
Dongheon Lee
JKJeong-Whun Kim
Jeong-Whun Kim
Purpose: Nocturnal sounds contain numerous information and are easily obtainable by a non-contact manner. Sleep staging using nocturnal sounds recorded from common mobile devices may allow daily at-home sleep tracking. The objective of this study is to introduce an end-to-end (sound-to-sleep stages) deep learning model for sound-based sleep staging designed to work with audio from microphone chips, which are essential in mobile devices such as modern smartphones. Patients and Methods: Two different audio datasets were used: audio data routinely recorded by a solitary microphone chip during polysomnography (PSG dataset, N=1154) and audio data recorded by a smartphone (smartphone dataset, N=327). The audio was converted into Mel spectrogram to detect latent temporal frequency patterns of breathing and body movement from ambient noise. The proposed neural network model learns to first extract features from each 30-second epoch and then analyze inter-epoch relationships of extracted features to finally classify the epochs into sleep stages. Results: Our model achieved 70% epoch-by-epoch agreement for 4-class (wake, light, deep, REM) sleep stage classification and robust performance across various signal-to-noise conditions. The model performance was not considerably affected by sleep apnea or periodic limb movement. External validation with smartphone dataset also showed 68% epoch-by-epoch agreement. Conclusion: The proposed end-to-end deep learning model shows potential of low-quality sounds recorded from microphone chips to be utilized for sleep staging. Future study using nocturnal sounds recorded from mobile devices at home environment may further confirm the use of mobile device recording as an at-home sleep tracker.