Alloys of GaInAsSbBi are grown by molecular beam epitaxy with various Bi compositions and subjected to a collimated beam of 63 MeV protons. Photoluminescence structures are used to evaluate the material’s minority carrier lifetime damage factor, and nBn structures are produced to investigate the detector’s rate of performance degradation. The lifetime damage factors of the photoluminescence structures containing 0.35% and 0.30% Bi are comparable at 2.4 × 10−6 and 2.2×10−6cm2/p+s, respectively, whereas the Bi-free counterpart sample exhibits a significantly higher lifetime damage factor of 3.8×10−6cm2/p+s. Two mid-wave infrared nBn detectors with 0.30% Bi absorbing regions, exhibiting a cutoff wavelength of 4.8 μm, are characterized in situ between step doses for dark current and quantum efficiency, and the dark-current-limited shot-noise-equivalent irradiance is calculated as a function of proton fluence. The noise-equivalent irradiance damage factor for both nBn structures is found to be 3.6 × 10−2 photons/p+, roughly 2.7× lower than other mid-wave infrared superlattice-based nBn detectors.
Pyroelectric detectors are commonly used as the reference detector when measuring a photon detector’s spectral response using a Fourier-transform infrared (FTIR) spectrometer because their fundamental spectral response is independent of wavelength. However, their photoresponse also depends on modulation frequency and, because the moving mirror in the FTIR modulates each wavelength of light at a different frequency, this introduces a frequency-dependent attenuation to measured interferograms. Depending on FTIR mirror speed, this results in significant variations of over 20% in certain regions of measured spectra. This work presents a physics-based transfer function approach to correct for this frequency-dependent attenuation and obtain accurate spectral measurements. Transfer function parameters for two different DLaTGS pyroelectric detectors are derived from spectra acquired at various FTIR mirror speeds. These functions are shown to effectively remove the frequency-dependent perturbations, aligning the spectra independent of mirror speed. Applying the correction when calculating the spectral response of a semiconductor-based infrared photon detector of interest yields an accurate spectral shape, while uncorrected spectra exhibit an unphysical increase at shorter wavelengths. This transfer function correction method provides a robust solution for accurate spectral measurements using pyroelectric detectors in FTIR spectroscopy.