Nan Liu

Nan Liu

Auto-generated profile, based on publicly available information

Nan Liu

School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
LDLinyang Dan
Linyang Dan
XCXin Chen
Xin Chen
GCGang Chen
Gang Chen
CLChangheng Li
Changheng Li
SLSuning Liang
Suning Liang
NLNan Liu
Nan Liu
Flash point (FP) critically determines the fire safety of transformer oils, yet ester-based oils, the sustainable alternative to mineral oils, face a critical trade-off between FP enhancement and viscosity control. Consequently, molecular structure modification strategies to enhance the FP of esters emerge as a forefront research focus in insulating materials. However, current investigations remain insufficient in elucidating structure-property relationships, as the underlying mechanisms by which key molecular parameters affect FP are not systematically understood, and reliable quantitative FP prediction models for ester-based oils are underdeveloped. Thus, defining clear structure-FP correlations and developing accurate prediction methods are of critical engineering importance to guide the optimization of ester modifications. In this study, a dataset comprising 906 FP data points for ester molecules is compiled through the systematic extraction of data from published literature and chemical databases. Based on this dataset, the predictive performance of four Graph Neural Network (GNN) models is comparatively evaluated, among which AttentiveFP performs best, achieving a mean coefficient of determination (R²) of 0.97 and a mean root-mean-square error (RMSE) of 11.59°C. To further elucidate molecular interaction mechanisms, the Gradient-weighted Class Activation Mapping (Grad-CAM) technique is employed to visualize atom-level contributions. By modifying the molecular structures and analyzing FP changes, we find that FP increases with carbon chain elongation and an increase in the number of ester groups. Ester group positions show a negligible correlation with FP, except when ester groups are located at side-chain terminals, where FP decreases. While the position of C=C double bonds has minimal effect, increasing their number slightly reduces FP.

22 May 2026 in High Voltage
Verified
Journal Article
Open access
LDLinyang Dan
Linyang Dan
XCXin Chen
Xin Chen
HWHao Wen
Hao Wen
FTFeng Tang
Feng Tang
JSJinlu Sheng
Jinlu Sheng
NLNan Liu
Nan Liu
Moisture is a sensitive issue for transformer oils, as it adversely affects the stability of insulation papers and dielectric strength of the oils. However, the lack of a quantitative model makes it challenging to evaluate the water solubility of ester‐based oils, which is an undesirable restriction for developing novel ester‐based oils. Herein, a quantitative model, which requires only the molecular structure as input, was developed to assess the water solubility. Experimental data revealed that both the molecular structure and temperature are the primary factors influencing the water saturation. Our model successfully reproduced the results with a deviation of < 10.0%. Next, we explored the mechanisms that govern the water saturation, focusing on the contribution of each group within molecular structures. It was found that the ester groups play a key role in determining the water saturation, and their contribution value varies from 180 mg/(kg·atom) (FR3) to 820 mg/(kg·atom) (palm fatty acid ester). This variation arises from the differences in the electrostatic potential (ESP), and a linear relationship between the maximum absolute ESP value and the group contribution value was revealed. Finally, we analysed the vapour–liquid equilibrium, revealing the change of water content in the oils when the operating conditions of transformers vary.

31 March 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
LDLin-Yang Dan
Lin-Yang Dan
HWHao Wen
Hao Wen
GCGang Chen
Gang Chen
XCXin Chen
Xin Chen
JSJin-Lu Sheng
Jin-Lu Sheng
NLNan Liu
Nan Liu
Water solubility in insulation oils is a critical parameter determining the lifespan of oil-immersed transformers, as it influences the aging rate, dielectric strength, etc. Despite extensive research, the lack of a quantitative model has left the underlying mechanisms poorly understood. In this paper, we proposed a quantitative model, requiring only the molecular structure as input, to analyze the water solubility. Furthermore, the effects of molecular structure and temperature were discussed in detail. First, experimental data reveal that the water saturation (Sw) of mineral oil increases exponentially with temperature. Our model successfully reproduces the results with an average deviation of 10.14%. Further investigation revealed that the electrostatic potential distributions (ESPs) of mineral oil molecules are unable to alleviate the electrostatic misfit of water molecules. Consequently, water molecules tend to self-aggregate rather than disperse in mineral oil, resulting in the high hydrophobicity. Based on the model, we quantified the changes in excess properties that are responsible for the temperature dependence of water solubility, and revealed the main reason for increased water solubility in mineral oil at higher temperatures. Finally, the vapor-liquid equilibrium curves were calculated and used to develop an empirical model. If the relative humidity of the air inside the transformer can be accurately measured, the water content in mineral oil can be quickly estimated. Additionally, utilizing the temperature mapping relationship from the empirical model, the water distribution in a transformer was determined through finite element simulation.