27 May 2019 in IEEE Transactions on Power Delivery
The current differential protection is introduced into active distribution network to improve the selectivity and reliability of protection. However, it is difficult to meet the synchronous requirement of differential protection for distribution networks. Therefore, this paper proposes an impedance differential protection for the active distribution network. The principle and criterion of the impedance differential protection are established according to the significant differences between differential impedance and restraint impedance during normal operation, external fault and internal fault. Furthermore, an auxiliary criterion is constructed by the amplitude characteristic of fault current to cope with the existing dead-zone fault. A complete protection scheme based on the proposed principle is designed. Several major factors are taken full consideration in the scheme including transition resistances, current transformer saturation, unsynchronized data, various penetrations and underground cables. Extensive digital simulations are conducted to verify the principle. Theoretical analyses and simulations demonstrate the effectiveness and advantage of this principle. Compared with current differential protection, the impedance differential protection significantly reduces the requirement of data synchronization and transmission band-width, which plays an important role in adapting to the communication infrastructure of distribution network.
26 February 2016 in IEEE Transactions on Smart Grid
A substation-area protective relay is proposed to overcome the inherent defects of the traditional backup protection system. The relay performs local backup protective functions for the whole substation and its connected transmission lines. The setting coordination of backup protections will be simplified by this relay with a shorter fixed time-delay. The algorithm of locating the faulted component employs the current differential principle with a self-adaptive restraint characteristic. The current sampled values are obtained by process-level networks inside the smart substation and by wide-area Ethernet between adjacent substations. The relay also works with the breaker states and the tripping generic object oriented substation event (GOOSE) from primary protections. A prototype based on the proposed scheme and IEC61850 standards has been developed by digital signal processor/field programmable gate array. The performance of the prototype was evaluated through the complete digital testing system using real time digital simulator/gigabit transceiver network and a communication simulator. Tests were carried out under different typical scenarios, such as fault transition resistances, inrush currents, current transformer saturations, and abnormal communications.
28 July 2017 in IEEE Transactions on Power Delivery
Sympathetic inrush is a magnetizing inrush phenomenon between two or more transformers when one of them is switched on under no load condition. This phenomenon has caused transformer differential protection maloperation in several cases due to the failure of the second harmonic restraint algorithm. Sympathetic inrush is very different in both the mechanism and characteristics from general inrush generated by a single transformer. Hence, a special identification method is required. The physical mechanism of sympathetic inrush between transformers is thoroughly studied to understand its characteristics, especially the alternate saturation feature. A substation-area information-based identification method is proposed to identify sympathetic inrush of the in-service transformer (IT). The alternate opposite saturation characteristic is used in the method. Both locking and unlocking criteria are designed for current differential protection to prevent the IT protection from maloperation. The proposed method is verified to be effective under different system conditions by simulations conducted in PSCAD and RTDS.
13 February 2023 in IEEE Transactions on Power Delivery
Current differential protection has been widely used as the primary protection of transformers. However, inrush currents during transformer energization can cause misoperation of the protection when the second harmonic restraint algorithm fails. This paper proposes a power differential protection scheme based on the fault component network (FCN), which is free from inrush detection and computationally cheap. First, the fault component differential power (FCDP), defined as the differential active power of a transformer in the FCN, is analyzed under different conditions. Second, a transformer protection scheme is presented based on the FCDP and the traditional differential power. A removal algorithm of decaying direct current (DDC) offset is developed to accurately estimate the FCDP. The performance of the scheme is tested under various conditions, including internal faults, external faults and transformer energization. The simulations using PSCAD, and Real Time Digital Simulator (RTDS), experiments in the Electrical Power Dynamic Laboratory (EPDL) and real recording data validate that the proposed method can protect the transformer reliably.
8 May 2020 in Electric Power Components and Systems
—In order to address the problems that model-based distance protection cannot correctly identify the fault phases in the DCTL (Double Circuit Transmission Lines on the same tower), a CNN-based (Convolutional Neural Network) fault phase identification method is proposed. The proposed method only uses the current and voltage waveforms of single-ended and single-circuit of DCTL to identify the fault phases. The CNN includes two convolution layers and two pooling layers, which are used to automatically extract the features of the waveforms. Furthermore, the CNN realizes the phase identification function by the extracted features. A training set is constructed by the simulation result of PSCAD, which is used for training the CNN to fit the mapping relationship between the waveforms and the fault types. Then, a validation set is used to optimize the hyper-parameters of CNN. Finally, several test sets are used to test the performance of CNN for phase identification. Compared with the traditional model-driven methods, the CNN-based method avoids manually analyzing the fault characteristics under different fault types and constructing identification criteria. The test results show that the proposed method can greatly improve the fault phase identification accuracy of DCTL.
19 July 2023 in International Journal of Electrical Power & Energy Systems