25 January 2024 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
RLRui Luo
Rui Luo
HGHoulei Gao
Houlei Gao
Fang PengFang Peng
Fang Peng
YGYifei Guo
Yifei Guo
Existing low-voltage ride-through (LVRT) methods of virtual synchronous generators (VSGs) are facing the problem of inverter damage due to prolonged overcurrent caused by the delay in fault detection. Additionally, the newly updated grid codes (GCs) mandate that inverter-based resources (IBRs) should inject negative-sequence current during asymmetrical faults. To address this issue while complying with the new GCs, this article proposes an adaptive LVRT method. At the onset of the fault, the proposed method compensates for the voltage difference between the reference and feedback values of voltage control loop, while simultaneously adjusting the angle output of the active power loop based on the phase change of the point of connection (POC) voltage and the active power output of the VSG. Thus, it enables a seamless transition between normal and LVRT conditions. Furthermore, it complies with the new GCs and guarantees the maximum utilization of the phase current. The method offers two notable advantages. First, it can achieve fast fault current limitation without the need for fault detection. Second, it eliminates the necessity for parameter design, making it straightforward to implement. The simulation results in PSCAD confirm the effectiveness of the proposed method under different asymmetrical fault conditions.

28 July 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Fang PengFang Peng
Fang Peng
HGHoulei Gao
Houlei Gao
YLYiqing Liu
Yiqing Liu
Sympathetic inrush is a magnetizing inrush phenomenon between two or more transformers when one of them is switched on under no load condition. This phenomenon has caused transformer differential protection maloperation in several cases due to the failure of the second harmonic restraint algorithm. Sympathetic inrush is very different in both the mechanism and characteristics from general inrush generated by a single transformer. Hence, a special identification method is required. The physical mechanism of sympathetic inrush between transformers is thoroughly studied to understand its characteristics, especially the alternate saturation feature. A substation-area information-based identification method is proposed to identify sympathetic inrush of the in-service transformer (IT). The alternate opposite saturation characteristic is used in the method. Both locking and unlocking criteria are designed for current differential protection to prevent the IT protection from maloperation. The proposed method is verified to be effective under different system conditions by simulations conducted in PSCAD and RTDS.

15 June 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
TYTong Yuan
Tong Yuan
HGHoulei Gao
Houlei Gao
Fang PengFang Peng
Fang Peng
LLLin Li
Lin Li
YZYunchi Zhang
Yunchi Zhang
QZQian Zhao
Qian Zhao
With the massive integration of distributed generations (DGs), distribution networks gradually become more active and flexible. Conventional overcurrent protection is difficult to adapt to such active distribution networks (ADNs). Current differential protection (CDP) is a good choice for solving this issue, but the multi-branch structure of ADNs especially the unmeasured T-connected load branch affects the protection’s sensitivity. Therefore, the paper proposes a quasipower differential protection (QDP) scheme based on Tellegen’s theorem. First, the feasibility of applying Tellegen’s theorem to ADNs was analyzed. On this basis, reasonable protection criteria were designed for different scenarios of ADNs. Then, an adaptive protection scheme was established, which can automatically adjust the criteria depending on the presence of Tconnected branches within the protected section. Finally, extensive simulations were carried out in an ADN model using PSCAD/EMTDC software. The simulation results demonstrate that the proposed protection scheme has excellent adaptability to network topologies, fault types, fault resistances, and network structures of ADNs.

13 February 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Fang PengFang Peng
Fang Peng
HGHoulei Gao
Houlei Gao
JHJiakai Huang
Jiakai Huang
YGYifei Guo
Yifei Guo
YLYiqing Liu
Yiqing Liu
YZYongfeng Zhang
Yongfeng Zhang
Current differential protection has been widely used as the primary protection of transformers. However, inrush currents during transformer energization can cause misoperation of the protection when the second harmonic restraint algorithm fails. This paper proposes a power differential protection scheme based on the fault component network (FCN), which is free from inrush detection and computationally cheap. First, the fault component differential power (FCDP), defined as the differential active power of a transformer in the FCN, is analyzed under different conditions. Second, a transformer protection scheme is presented based on the FCDP and the traditional differential power. A removal algorithm of decaying direct current (DDC) offset is developed to accurately estimate the FCDP. The performance of the scheme is tested under various conditions, including internal faults, external faults and transformer energization. The simulations using PSCAD, and Real Time Digital Simulator (RTDS), experiments in the Electrical Power Dynamic Laboratory (EPDL) and real recording data validate that the proposed method can protect the transformer reliably.

13 October 2023 in Electric Power Systems Research
Verified
Journal Article
Closed access
LLLin Li
Lin Li
HGHoulei Gao
Houlei Gao
TYTong Yuan
Tong Yuan
Fang PengFang Peng
Fang Peng
YXYongduan Xue
Yongduan Xue

11 April 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZLZhen Liu
Zhen Liu
HGHoulei Gao
Houlei Gao
Fang PengFang Peng
Fang Peng
YFYuewei Fan
Yuewei Fan
To address the issues of slow operation speed, high synchronization requirements, and susceptibility to the influence of distributed capacitance in existing pilot protection for LCC-HVDC transmission lines, a novel pilot protection method utilizing the measured impedance characteristics is proposed. Measured impedance is utilized to characterize the frequency-domain differences under various fault conditions. Under forward fault conditions, the measured impedance exhibits purely capacitive or purely inductive characteristics within a specific frequency band. Under reverse fault conditions, the measured impedance corresponds to the transmission line wave impedance, with the line-mode wave impedance stabilizing within a specific frequency band, where the imaginary part much smaller than the real part. Leveraging the characteristics, a pilot protection scheme is proposed. Simulation analysis shows that the protection method can fast and correctly identify faults, withstand fault impedances of up to 900 Ω, is unaffected by distributed capacitance, and has low synchronization requirements on both sides. The method is capable of being applied as a rapid backup protection for long-distance LCC-HVDC transmission lines.