This paper presents a 401-428-MHz BFSK/QPSK transmitter (TX) with two types of fractional-injection-locking techniques for multichannel transmission capabilities. A ΔΣbased injection-locked ring oscillator is proposed to achieve fine frequency tuning with a frequency resolution of 1.3 kHz. The proposed method facilitates multichannel BFSK modulation. For high data rate wideband QPSK modulation, frequency tuning is achieved through sequential injection locking. The TX performs 550 Kb/s for BFSK and 11 Mb/s for band-shaped QPSK with EVM of 4.4% and 4.9%, respectively. It also achieves a settling time of less than 0.8 μs. This helps to save operating power of the wireless medical devices with duty-cycling protocol employed in the TX. Fabricated in 130-nm process technology, the TX achieves an energy efficiency of 370 pJ/b while delivering -13 dBm of output power with 1-V supply.
12 June 2019 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents a wireless vital signs monitoring system-on-chip including three-lead ECG, bio-impedance (Bio-Z) and body temperature. A Bio-Z readout channel with early demodulation is introduced to detect small body impedance change below 300 mΩ under large baseline resistance while consuming power of 9.8 μW. A direct temperature-to-digital converter is also incorporated, which achieves an absolute resolution of 0.023 °C and inaccuracy less than ±0.13 °C over temperature range of 32-42 °C. The quantized vital sign signal is transmitted through a multi-channel reconfigurable QPSK/BFSK transmitter (TX) to accommodate different power-constraint scenarios. Fabricated in 130-nm CMOS technology with a total die area of 6.25 mm 2 , the proposed SoC only consumes 74 μW under 0.9-V supply.
19 May 2017 in IEEE Transactions on Biomedical Circuits and Systems
An 8-channel wireless neural signal processing IC, which can perform real-time spike detection, alignment, and feature extraction, and wireless data transmission is proposed. A reconfigurable BFSK/QPSK transmitter (TX) at MICS/MedRadio band is incorporated to support different data rate requirement. By using an Exponential Component-Polynomial Component (ECPC) spike processing unit with an incremental principal component analysis (IPCA) engine, the detection of neural spikes with poor SNR is possible while achieving 625× data reduction. For the TX, a dual-channel at 401 MHz and 403.8 MHz are supported by applying sequential injection locked techniques while attaining phase noise of -102 dBc/Hz at 100 kHz offset. From the measurement, error vector magnitude (EVM) of 4.60%/9.55% with power amplifier (PA) output power of -15 dBm is achieved for the QPSK at 8 Mbps and the BFSK at 12.5 kbps. Fabricated in 65 nm CMOS with an active area of 1 mm 2 , the design consumes a total current of 5~5.6 mA with a maximum energy efficiency of 0.7 nJ/b.