Aurelien F. Stalder

Aurelien F. Stalder

Auto-generated profile, based on publicly available information

Aurelien F. Stalder

Siemens Healthcare, Erlangen, Germany

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
ASA.F. Stalder
A.F. Stalder
GKG. Kulik
G. Kulik
DSD. Sage
D. Sage
LBL. Barbieri
L. Barbieri
PHP. Hoffmann
P. Hoffmann

1 July 2010 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
ASAurélien F. Stalder
Aurélien F. Stalder
TMTobias Melchior
Tobias Melchior
MMMichael Müller
Michael Müller
DSDaniel Sage
Daniel Sage
TBThierry Blu
Thierry Blu
MUMichael Unser
Michael Unser

27 October 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ASA.F. Stalder
A.F. Stalder
MRM.F. Russe
M.F. Russe
AFA. Frydrychowicz
A. Frydrychowicz
JBJ. Bock
J. Bock
JHJ. Hennig
J. Hennig
MMM. Markl
M. Markl

25 June 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
AFAlex Frydrychowicz
Alex Frydrychowicz
ASAurélien F. Stalder
Aurélien F. Stalder
MRMaximilian F. Russe
Maximilian F. Russe
JBJelena Bock
Jelena Bock
SBSimon Bauer
Simon Bauer
MMMichael Markl
Michael Markl
Purpose: To assess the distribution and regional differences of flow and vessel wall parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) in the entire thoracic aorta.Materials and Methods: Thirty‐one healthy volunteers (mean age = 23.7 ± 3.3 years) were examined by flow‐sensitive four‐dimensional (4D)‐MRI at 3T. For eight retrospectively positioned 2D analysis planes distributed along the thoracic aorta, flow parameters and vectorial WSS and OSI were assessed in 12 segments along the vascular circumference.Results: Mean absolute time‐averaged WSS ranged between 0.25 ± 0.04 N/m2 and 0.33 ± 0.07 N/m2 and incorporated a substantial circumferential component (–0.05 ± 0.04 to 0.07 ± 0.02 N/m2). For each analysis plane, a segment with lowest absolute WSS and highest OSI was identified which differed significantly from mean values within the plane (P < 0.05). The distribution of atherogenic low WSS and high OSI closely resembled typical locations of atherosclerotic lesions at the inner aortic curvature and supraaortic branches.Conclusion: The normal distribution of vectorial WSS and OSI in the entire thoracic aorta derived from flow‐sensitive 4D‐MRI data provides a reference constituting an important perquisite for the examination of patients with aortic disease. Marked regional differences in absolute WSS and OSI may help explaining why atherosclerotic lesions predominantly develop and progress at specific locations in the aorta. J. Magn. Reson. Imaging 2009;30:77–84.

18 December 2009 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JBJelena Bock
Jelena Bock
AFAlex Frydrychowicz
Alex Frydrychowicz
ASAurélien F. Stalder
Aurélien F. Stalder
TBThorsten A. Bley
Thorsten A. Bley
HBHans Burkhardt
Hans Burkhardt
MMMichael Markl
Michael Markl
Time‐resolved phase contrast (PC) MRI with velocity encoding in three directions (flow‐sensitive four‐dimensional MRI) can be employed to assess three‐dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three‐dimensional PC MR angiography (MRA). As PC‐MRA is sensitive to available signal‐to‐noise ratio, standard and novel blood pool contrast agents may help to enhance PC‐MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal‐to‐noise ratio, PC‐MRA quality, and subsequent three‐dimensional stream‐line visualization in the thoracic aorta was determined. Flow‐sensitive four‐dimensional MRI data acquired with contrast agent provided significantly improved signal‐to‐noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three‐dimensional PC‐MRA with reference standard contrast‐enhanced MRA was good for both contrast agents, with improved PC‐MRA performance for blood pool contrast agent, particularly for the smaller supra‐aortic branches. For three‐dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed. Magn Reson Med, 2010.

18 December 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
AHA. Harloff
A. Harloff
FAF. Albrecht
F. Albrecht
JSJ. Spreer
J. Spreer
ASA.F. Stalder
A.F. Stalder
JBJ. Bock
J. Bock
MMM. Markl
M. Markl
To determine three‐dimensional (3D) blood flow patterns in the carotid bifurcation, 10 healthy volunteers and nine patients with internal carotid artery (ICA) stenosis ≥50% were examined by flow‐sensitive 4D MRI at 3T. Absolute and mean blood velocities, pulsatility index (PI), and resistance index (RI) were measured in the common carotid arteries (CCAs) by duplex sonography (DS) and compared with flow‐sensitive 4D MRI. Furthermore, 3D MRI blood flow patterns in the carotid bifurcation of volunteers and patients before and after recanalization were graded by two independent readers. Blood flow velocities measured by MRI were 31–39% lower than in DS. However, PI and RI differed by only 13–16%. Rating of 3D flow characteristics in the ICA revealed consistent patterns for filling and helical flow in volunteers. In patients with ICA stenosis, 3D blood flow visualization was successfully employed to detect markedly altered filling and helical flow patterns (forward‐moving spiral flow) in the ICA bulb and to evaluate the effect of revascularization, which restored filling and helical flow. Our results demonstrate the feasibility of flow‐sensitive 4D MRI for the quantification and 3D visualization of physiological and pathological flow patterns in the carotid artery bifurcation. Magn Reson Med 61:65–74, 2009.