Xinyi Deng

Xinyi Deng

Auto-generated profile, based on publicly available information

Xinyi Deng

School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
JTJingguang Tang
Jingguang Tang
XQXuefeng Qiao
Xuefeng Qiao
HCHongkun Chen
Hongkun Chen
JZJiahui Zhu
Jiahui Zhu
XDXinyi Deng
Xinyi Deng
Virtual synchronous generator (VSG) strategy is an effective means for renewable energy sources to be connected to power grids. Meanwhile, a greater focus should be on the multi-VSG system's (MVS) transient stability issue. Regarding the MVS with resistive superconducting fault current limiters (R-SFCLs), this paper proposes a control method based on deep reinforcement learning (DRL) agent for increasing the transient stability. Firstly, the theoretical model of the MVS incorporating R-SFCLs is established, and R-SFCLs are used to limit the fault current in VSGs and keep the fault ride-through (FRT) operation. Then, the working mechanism of the proposed method is elaborated, by designing the Markov decision process (MDP) model of transient control, and applying the improved softmax deep deterministic policy gradients (SD2) algorithm to train the DRL agent. The advanced time series feature extraction network (TSFEN) based on the convolutional neural network (CNN) and gate recurrent unit (GRU) is suggested to enhance the actor network and critic network of the SD2. A detailed simulation model is created using MATLAB, and a comparison with the traditional VSG control, only R-SFCL, deep deterministic policy gradients (DDPG) algorithm, and improved power loop scheme is conducted. From multiple cases, the proposed approach can satisfactorily boost the transient stability of the MVS, and the generalization ability of the DRL agent under different untrained scenarios is validated. The proposed method's validity and suitability are well-confirmed.

2 July 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
GLGuocheng Li
Guocheng Li
HCHongkun Chen
Hongkun Chen
XQXuefeng Qiao
Xuefeng Qiao
MDMeng Ding
Meng Ding
JYJian Yang
Jian Yang
To cope with the DC fault isolation issue of a hybrid high-voltage direct-current (HVDC) system, a promising option is to coordinate superconducting fault current limiter (SFCL) and DC circuit breaker (DCCB). In this paper, a multi-objective Pareto optimization method is proposed for the combinatorial use of a resistive-type SFCL and a DCCB in a hybrid HVDC. Firstly, theoretical modeling and coordinated action process of the SFCL and DCCB are expounded. Then, a multi-objective function that collaboratively minimizes the SFCL resistance and the breaking capability of the DCCB is established, and a non-dominated sorting genetic algorithm-II (NSGA-II) is utilized to acquire the satisfying Pareto optimal solution set. The optimizing calculation is done in a 320 kV hybrid HVDC for validating the approach efficacy. Besides, transient simulations are implemented by PSCAD/EMTDC, and comprehensive performance analyses are executed to evaluate the rationality of the combinatorial optimal schemes. The findings indicate that the DC fault current is reduced and interrupted with the minimal rating of the resistive-type SFCL and the DCCB, and also, the HVDC system's safe and stable operation will be ensured. Therefore, the proposed approach is adequately verified for its availability and feasibility.

14 February 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
JTJingguang Tang
Jingguang Tang
HDHong Dong
Hong Dong
RHRuizhe Hu
Ruizhe Hu
XWXuechun Wang
Xuechun Wang
XDXinyi Deng
Xinyi Deng
Multiple microgrid (multi-MG) clusters based on virtual synchronous generator (VSG) control can preferably incorporate renewable energies. Nevertheless, the power angle stability (PAS) of VSG–controlled multi-MG clusters is easy to be influenced by grid faults. In this paper, resistive superconducting fault current limiters (R–SFCLs) are introduced to deal with this PAS problem. It is designed to install the R-SFCLs at the point of common coupling (PCC) of each MG in the clusters. The transient stability mechanism based on power balance and swing equation is analyzed to clarify the impacts of the R-SFCLs. Through MATLAB, a simulation model of three VSG-controlled MGs with R-SFCLs is built, and different fault scenarios are imitated for checking the performance behaviors of the R-SFCLs. From the simulation results, the R-SFCLs can visibly suppress the overcurrent inrush and assist the MGs in the clusters to fulfill the fault-ride through (FRT). Moreover, the energy dissipation of the R–SFCLs is calculated, and an improved power balance property is obtained in the multi-MG clusters to alleviate the power-angle fluctuations. Consequently, the effectiveness of the R–SFCLs on reducing the relative power angle variation is demonstrated, and the transient stability of the multi-MG clusters withstanding the three-phase faults is favorably enhanced.

21 June 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
RHRuizhe Hu
Ruizhe Hu
XDXinyi Deng
Xinyi Deng
HCHongkun Chen
Hongkun Chen
YLYanhong Li
Yanhong Li
HHHuiwen He
Huiwen He
This paper investigates modified ux-coupling-type superconducting fault current limiters (SFCLs) for enhancing the transient stability of a multi-machine power system (MMPS). The clustering architecture of the MMPS with the modified SFCLs is presented, and the transient energy function (TEF) of the MMPS is established. Through clarifying the potential influence of the modified SFCLs, theoretical analysis signifies that the modified SFCLs can reduce the transient energy accumulation during the fault-feeding period, and increase the transient stability margin of the MMPS. Using MATLAB/Simulink, a benchmark IEEE 9-bus system with the SFCLs is modeled, and the simulation analysis of the generator rotor swing behaviors is carried out. Varying the resistive-inductive parameters and altering the positions of the SFCLs are considered, and the TEF method is applied to gain quantitative effects. The simulation findings in different scenarios testify the correctness of the theoretical analysis. The presence of the SFCLs can availably reduce the generator rotor oscillating and restrain the transient energy changing, and meanwhile, an extension of the critical clearance time is achieved for the MMPS.

4 August 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
MDMeng Ding
Meng Ding
HCHongkun Chen
Hongkun Chen
XWXuechun Wang
Xuechun Wang
XDXinyi Deng
Xinyi Deng
HHHuiwen He
Huiwen He
Power electronic transformers (PETs) can be used to interconnect different voltages and forms of electrical systems, and enable to offer higher operation efficiency and flexible power flow controllability. This paper focuses on the fault ride-through (FRT) problem of a PET interconnecting medium voltage (MV) and low voltage (LV) power systems, and the solution of a resistive superconducting fault current limiter (SFCL) is proposed. Firstly, theoretical modeling of the PET and the SFCL is addressed, and a suitable control strategy is applied to realize reliable power exchange between the LV and MV systems. Then, in regards to a fault at the PET's output-terminal, the fault developing process is probed, and considering the SFCL's quench behavior, the PET's current variations are clarified. Further, a 3 MW PET with a SFCL is modeled in MATLAB/Simulink, and through changing the fault severity and the SFCL parameter, different simulations are implemented. The results reveal that the SFCL stabilizes the PET from multiple aspects. A visible current-limiting function is achieved, and the voltage dynamic fluctuations at the AC and DC sides of the PET are effectively alleviated. Meanwhile, the power delivery from the LV to the MV system is smoothed, and a successful FRT fulfillment is gained.

2 July 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
XDXinyi Deng
Xinyi Deng
MDMeng Ding
Meng Ding
HCHongkun Chen
Hongkun Chen
GLGuocheng Li
Guocheng Li
HHHuiwen He
Huiwen He
Building multiple microgrid (multi-MG) clusters is conducive to accessing high penetration of renewable generations, consuming electric energies locally, and reducing operating losses. Nevertheless, it causes a challenge that the interconnectivity of multi-MG clusters may be seriously affected by short-circuit faults. To figure out the issue, this paper puts forward a solution of using flux-coupling-type superconducting fault current limiters (SFCLs), which are positioned at the points of common coupling (PCCs) among the multi-MG clusters and the distribution system. Considering the power exchange and balance under faults, the interconnectivity characteristics of the multi-MG clusters are theoretically analyzed, and the potential actions of the SFCLs to boost the interconnectivity are expounded. Using MATLAB, a modified IEEE 13-node distribution system containing multi-MG clusters and flux-coupling-type SFCLs is modeled, and different fault scenarios are simulated to assess the efficacy and suitability of the proposed solution. From the findings, the SFCLs can very usefully relieve the power fluctuation and mitigate the PCC voltage drop for the multi-MG clusters. Not only the operation of tripping off the multi-MG clusters is efficaciously avoided, but also a stronger power support capability withstanding the fault rush is appreciatively obtained.