Kun-Jhih Lin

Kun-Jhih Lin

Auto-generated profile, based on publicly available information

Kun-Jhih Lin

Technology Translation Center for Medical Device, Chung Yuan Christian University, Taoyuan, Taiwan

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Injury
Verified
Journal Article
Closed access
YZYa-Kui Zhang
Ya-Kui Zhang
HWHung-Wen Wei
Hung-Wen Wei
KLKang-Ping Lin
Kang-Ping Lin
WCWen-Chuan Chen
Wen-Chuan Chen
CTCheng-Lun Tsai
Cheng-Lun Tsai
KLKun-Jhih Lin
Kun-Jhih Lin

6 May 2011 in Clinical Biomechanics
Verified
Journal Article
Closed access
PDF file
KLKun-Jhih Lin
Kun-Jhih Lin
CHChang-Hung Huang
Chang-Hung Huang
YLYu-Liang Liu
Yu-Liang Liu
WCWen-Chuan Chen
Wen-Chuan Chen
TCTsung-Wei Chang
Tsung-Wei Chang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng

1 January 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
KLKun-Jhih Lin
Kun-Jhih Lin
HWHung-Wen Wei
Hung-Wen Wei
KLKang-Ping Lin
Kang-Ping Lin
CTCheng-Lun Tsai
Cheng-Lun Tsai
PLPei-Yuan Lee
Pei-Yuan Lee
Adequately shaped femoral plate is critical for the fixation of fracture in the pertrochanteric regions. Lateral aspect of greater trochanter is an important region where the proximal femoral plate anchored. However, little is known regarding the morphology of greater trochanter. The objective of this study was to measure main dimensions of greater trochanter and other regions in the proximal end of the femur to provide an anatomical basis for the design of the proximal femoral plate. Anthropometric data on the proximal femur were performed utilizing three-dimensional computational modeling. Computed tomography images of healthy femurs in 53 women and 47 men were contributed to three-dimensional femur modeling. All data were compared between male and female femora. The results showed that mean values for male group were found to be greater in most of measured femoral dimensions. Oppositely, females demonstrated higher neck-shaft angle on anteroposterior view and femoral anteversion angle. The anthropometric data can be used for the anatomical shape design of femoral plates for osteosynthesis of fractures in the trochanteric regions. A distinct plate design may be necessary to accommodate differences between the genders.

28 April 2018 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JYJesse Chieh-Szu Yang
Jesse Chieh-Szu Yang
KLKang-Ping Lin
Kang-Ping Lin
HWHung-Wen Wei
Hung-Wen Wei
WCWen-Chuan Chen
Wen-Chuan Chen
CCChao-Ching Chiang
Chao-Ching Chiang
KLKun-Jhih Lin
Kun-Jhih Lin
The far cortical locking (FCL) system, a novel bridge-plating technique, aims to deliver controlled and symmetric interfragmentary motion for a potential uniform callus distribution. However, clinical data for the practical use of this system are limited. The current study investigated the biomechanical effect of a locking plate/far cortical locking construct on a simulated comminuted diaphyseal fracture of the synthetic bones at different distance between the plate and the bone. Biomechanical in vitro experiments were performed using composite sawbones as bone models. A 10-mm osteotomy gap was created and bridged with FCL constructs to determine the construct stiffness, strength, and interfragmentary movement under axial compression, which comprised one of three methods: locking plates applied flush to bone, at 2 mm, or at 4 mm from the bone. The plate applied flush to the bone exhibited higher stiffness than those at 2 mm and 4 mm plate elevation. A homogeneous interfragmentary motion at the near and far cortices was observed for the plate at 2 mm, whereas a relatively large movement was observed at the far cortex for the plate applied at 4 mm. A plate-to-bone distance of 2 mm had the advantages of reducing axial stiffness and providing nearly parallel interfragmentary motion. The plate flush to the bone prohibits the dynamic function of the far cortical locking mechanism, and the 4-mm offset was too unstable for fracture healing.

12 April 2017 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JYJesse Chieh-Szu Yang
Jesse Chieh-Szu Yang
KLKun-Jhih Lin
Kun-Jhih Lin
HWHung-Wen Wei
Hung-Wen Wei
CTCheng-Lun Tsai
Cheng-Lun Tsai
KLKang-Ping Lin
Kang-Ping Lin
PLPei-Yuan Lee
Pei-Yuan Lee
The clavicle has a complex geometry that makes plate fixation technically difficult. The current study aims to measure the anatomical parameters of Chinese clavicles as reference for plate design. One hundred clavicles were analyzed. The clavicle bone model was reconstructed by using computed tomography images. The length, diameters, and curvatures of the clavicle were then measured. The female clavicle was shorter, more slender, and less curved in lateral part than the male clavicle. There was a positive relationship between height and clavicle parameters except lateral curve and depth. The measurements of Chinese clavicles were generally smaller than Caucasians. The clavicle curves were correlated with the bone length; thus consideration of the curve variations may be necessary as designing size distribution of clavicle plate.

3 January 2014 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
CHChang‐Hung Huang
Chang‐Hung Huang
LHLin‐I Hsu
Lin‐I Hsu
KLKun‐Jhih Lin
Kun‐Jhih Lin
TCTing‐Kuo Chang
Ting‐Kuo Chang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
CHChun‐Hsiung Huang
Chun‐Hsiung Huang